Showing 1 to 7 of 7 for “"stator fault"”.
-
Stator fault analysis of synchronous machines
The stator inter-turn faults can result in catastrophic failure of the electric machines leading to extended downtime of the equipment, increased cost of repair and heavy financial losses in the industries. In the recent trends, online fault diagnosis of the electric machines that arc employed in …
-
Parameter Identification And Fault Detection For Reliable Control Of Permanent Magnet Motors
… objective of this dissertation is to develop new fault detection, identification, estimation and control algorithms that will be used to detect winding stator fault, identify the motor parameters and optimally control machine during faulty condition. Quality or proposed algorithms for Fault …
-
Contribuição ao melhoramento da operação durante afundamentos de tensão de geradores de indução duplamente alimentados baseados em conversores modulares multinível
… disturbances, especially voltage sags since the stator is directly connected to the grid. This feature highlights a fundamental challenge which is to provide fault support. Given this problem’s relevance, this thesis proposes improving DFIG supportability to a voltage sag in the grid through a …
-
Current Based Fault Detection and Diagnosis of Induction Motors. Adaptive Mixed-Residual Approach for Fault Detection and Diagnosis of Rotor, Stator, Bearing and Air-Gap Faults in Induction Motors Using a Fuzzy Logic Classifier with Voltage and Current Measurement only.
… One particular aspect of this research is the fault detection and diagnosis (FDD) of induction motors for use in a condition based maintenance (CBM) strategy; by effectively tracking the condition of the motor, maintenance action need only be carried out when necessary. This type of maintenance …
-
Reliable Multiphase Induction Motor Drives
… reported failures in induction motors are due to stator faults. It is well known that a stator fault starts as an inter-turn fault within a phase and then propagates into phase-to-phase and phase-to-ground faults that can then lead to complete shutdown of the motor. Two approaches have been taken …
-
Υπολογισμός ηλεκτρομαγνητικών μεγεθών και πρόβλεψη συμπεριφοράς μιας σύγχρονης μηχανής με έκτυπους πόλους σε περιπτώσεις σφαλμάτων με τη χρήση της μεθόδου πεπερασμένων στοιχείων
… Additionally, the case of an internal fault in the stator winding for the two cases mentioned above was investigated. The electromagnetic torque and the magnetic flux density in each case were calculated and studied, as well as the stator and rotor currents, including the damper cage, …
-
Algoritmy monitorování a diagnostiky pohonů se synchronními motory
… konvenční metody pracující na základě analýz statorového napětí a rezidua statorových proudů. Následují tři autorem vytvořené algoritmy detekce poruchy, které využívají rozšířený Kalmanův filtr společně s modifikovaným modelem motoru. Je popsána implementace algoritmů na mikrokontroléru a jsou …