Showing 1 to 7 of 7 for “"stator faults"”.

  1. Reliable Multiphase Induction Motor Drives

    … reported failures in induction motors are due to stator faults. It is well known that a stator fault starts as an inter-turn fault within a phase and then propagates into phase-to-phase and phase-to-ground faults that can then lead to complete shutdown of the motor. Two approaches have been taken …

    tamu Repository record for Reliable Multiphase Induction Motor Drives (opens in a new tab)

  2. COMPUTERIZED GENERATOR DIFFERENTIAL PROTECTION

    … presence of phase to ground and phase to phase stator faults on power system generators. The fault/no-fault decisions are based on the amplitude ratio of the "fault" and "average-through" currents from a selected generator phase. Techniques for fast amplitude extraction from sampled inputs are …

    sask Repository record for COMPUTERIZED GENERATOR DIFFERENTIAL PROTECTION (opens in a new tab)

  3. Detailed investigation of negative sequence current compensation technique for stator shorted turn fault detection of induction motors.

    … applications that capable of identifying stator faults in induction motor as well as producing fast and reliable results using a simple measurement technique. However, the technique is sensitive to asymmetrical sources of negative sequence, not only due to motor faults but also due to the …

    adelaide Repository record for Detailed investigation of negative sequence current compensation technique for stator shorted turn fault detection of induction motors. (opens in a new tab)

  4. Current-, force-, and vibration-based techniques for induction motor condition monitoring

    … discover the best indicators of induction motor faults, as well as suitable techniques for monitoring the condition of induction motors. Numerical magnetic field analysis was used with the objective of generating reliable virtual data to be analysed with modern signal processing and …

    aalto Repository record for Current-, force-, and vibration-based techniques for induction motor condition monitoring (opens in a new tab)

  5. Stator inter-turn fault detection of doubly-fed induction generators using rotor current and search coil voltage signature analysis

    … are within power range of 200KW-2MW and have stator windings rated at 690V, which are highly susceptible to inter-turn faults. This fault type account for more than 40% of the total failure causes of the generator. A reliable fault diagnostic system to detect this fault at incipient stage is …

    uvic Repository record for Stator inter-turn fault detection of doubly-fed induction generators using rotor current and search coil voltage signature analysis (opens in a new tab)

  6. Investigation of single and multiple faults under varying load conditions using multiple sensor types to improve condition monitoring of induction machines.

    … motor while it is operating in order to detect faults. For this purpose normally a single sensor type, for example current is used to detect broken rotor bar using fault frequency components only under the full-load condition or a limited number of load cases. The correlations among the …

    adelaide Repository record for Investigation of single and multiple faults under varying load conditions using multiple sensor types to improve condition monitoring of induction machines. (opens in a new tab)

  7. Identifikace poruch u vinutí střídavých strojů během výroby

    V práci je popsán výrobní proces statoru, zejména se zaměřením na vinutí, izolaci a měděný drát. Je pojednáno o možnostech poškození izolace během výrobního procesu. Následuje statistika ohledně poruch statorů odhalených v průběhu výrobního procesu a zákaznických reklamací. Je vypracován přehled …

    brno-tech Repository record for Identifikace poruch u vinutí střídavých strojů během výroby (opens in a new tab)