  1. Sensorless Stator Winding Temperature Estimation for Induction Machines

    The organic materials used for stator winding insulation are subject to deterioration from thermal, electrical, and mechanical stresses. Stator winding insulation breakdown due to excessive thermal stress is one of the major causes of electric machine failures; therefore, prevention of such a …

    gatech Repository record for Sensorless Stator Winding Temperature Estimation for Induction Machines (opens in a new tab)

  2. Three-phase stator winding configuration producing one-sided magnetic field

    … This dissertation investigates a three-phase stator winding configuration that would produce a one-sided magnetic field. The design was created in hopes of increasing the torque output and power density of the motor, without effecting the overall efficiency of the motor. Both an 8-pole PMSM …

    alabama Repository record for Three-phase stator winding configuration producing one-sided magnetic field (opens in a new tab)

  3. Stator Winding Fault Detection Techniques for Permanent Magnet Machine Drives

    … fault, also known as turn fault, in PM machine stator windings by enhancing the detectability, robustness against transient states, and reducing the sensitivity towards other faults especially high resistance connection (HRC) fault. Firstly, it proposes a turn fault detection method based on …

    whiterose Download PDF for Stator Winding Fault Detection Techniques for Permanent Magnet Machine Drives (opens in a new tab)

  4. Dielectric frequency response analysis applied to stator winding insulation systems

    … applied to detect the deterioration of stator winding insulation systems. For the main investigation, three newly manufactured stator coils with a rated voltage of 13.8 kV were aged using the thermal cycle testing procedures described in IEEE 1310 and an extended and modified version of …

    ets-quebec Download PDF for Dielectric frequency response analysis applied to stator winding insulation systems (opens in a new tab)

  5. Characterization of Stator Winding Short-Circuit Faults in Interior Permanent-Magnet Motor-Drive Systems

    … permanent-magnet electric machine experiencing winding short-circuit faults of varying severity. The experimental data collected from the faulted machine is from both motoring operation energized by a PWM sensorless ac drive as well as generating operation driven by the test bed dynamometer with …

    marquette Repository record for Characterization of Stator Winding Short-Circuit Faults in Interior Permanent-Magnet Motor-Drive Systems (opens in a new tab)

  6. Transient voltage distribution in stator winding of electrical machine fed from a frequency converter

    … and distribution of fast voltage within the stator winding of an electric machine fed from a frequency converter. Three methods of predicting the magnitude and distribution of fast voltages within form windings commonly used in medium and high voltage machines are described. These methods …

    aalto Repository record for Transient voltage distribution in stator winding of electrical machine fed from a frequency converter (opens in a new tab)

  7. Online Condition Monitoring of Stator Winding Insulation State of Electric Machines in Electrified Vehicles

    … on online monitoring of electrical machine’s winding insulation degradation. A comprehensive review of literature revealed certain research gaps. The first one is on selection of the most effective insulation degradation indicator for online condition monitoring without increasing motor drive …

    concordia Download PDF for Online Condition Monitoring of Stator Winding Insulation State of Electric Machines in Electrified Vehicles (opens in a new tab)

  8. Simulation and experimental verification of universal high frequency induction machine model for arbitrary stator winding connections

    … frequency induction machine model for arbitrary stator winding connections is crucial to determine and investigate the electromagnetic interference (EMI) issues concerning stator winding reflected wave overvoltage and bearing discharge current. It is also fundamental in determining proper motor …

    ubc Repository record for Simulation and experimental verification of universal high frequency induction machine model for arbitrary stator winding connections (opens in a new tab) Download PDF for Simulation and experimental verification of universal high frequency induction machine model for arbitrary stator winding connections (opens in a new tab)

  9. Modeling and Detection of Stator Winding Insulation Degradation in VSI-fed Electric Machines Under High dv/dt

    … pulse voltages for motor operation. Motor’s winding insulation undergoes additional electrical stress due to high voltage slew rate (dv/dt) resulted from the use of VSI, which may cause accelerated insulation degradation. To investigate and quantify this electrical stress, various modeling …

    concordia Download PDF for Modeling and Detection of Stator Winding Insulation Degradation in VSI-fed Electric Machines Under High dv/dt (opens in a new tab)

  10. Effects of slotting and unipolar flux on magnetic pull in a two-pole induction motor with an extra four-pole stator winding

    … the radial magnetic forces between the rotor and stator in twopole induction machines. The magnetic forces arise from rotor eccentricity. The asymmetric air-gap makes the flux density on one side of the rotor stronger than on the opposite side. This produces magnetic pull. The magnetic flux …

    aalto Repository record for Effects of slotting and unipolar flux on magnetic pull in a two-pole induction motor with an extra four-pole stator winding (opens in a new tab)

  11. Active thermal protection for induction motors fed by motor control devices

    … overload is one of the major root causes of stator winding insulation failure, an accurate and reliable monitoring of the stator winding temperature is crucial to increase the mean time to catastrophic motor breakdown, and to reduce the extraordinary financial losses due to unexpected process …

    gatech Repository record for Active thermal protection for induction motors fed by motor control devices (opens in a new tab)

  12. Online UHF measurement of partial discharge in stator windings using microstrip patch antennas

    … help evaluate the condition of rotating machine winding insulation. PD occurs in stator winding groundwall insulation due to the voltage stress in voids left by the manufacturing process, but it also occurs when other defects are present in the insulation system. PD from each type of defect in a …

    manitoba Repository record for Online UHF measurement of partial discharge in stator windings using microstrip patch antennas (opens in a new tab)

  13. Manufacture and Analysis of Compressed Aluminium Stator Windings for Low Voltage Electrical Machines

    … predictable, uniform coil temperatures on the stator winding<br/>design. To meet these demands, this thesis proposes multistranded, transposed and compressed,<br/>concentrated Aluminium coils for a low-cost 48 V eMachine stator winding.<br/>The three main research objectives concern the …

    bristol Repository record for Manufacture and Analysis of Compressed Aluminium Stator Windings for Low Voltage Electrical Machines (opens in a new tab) Download PDF for Manufacture and Analysis of Compressed Aluminium Stator Windings for Low Voltage Electrical Machines (opens in a new tab)

  14. Electromagnetic Analysis of Stator Ground Faults in Synchronous Generators

    There are many stator ground faults protection schemes available in the industry. These schemes relatively perform well in detecting the faults in the stator winding. The protection of the neutral point vicinity is the challenge because of the low voltage induced in that area. The 100% stator …

    tamu Repository record for Electromagnetic Analysis of Stator Ground Faults in Synchronous Generators (opens in a new tab)

  15. Operation of interior permanent magnet synchronous machines with fractional slot concentrated windings under both healthy and faulty conditions

    … machines can be designed to better withstand stator insulation failures. In this work, the performance of three fault tolerant fractional slot concentrated winding machine designs experiencing stator winding insulation failure are evaluated. Two of the machines are designed with double-layer …

    msu

  16. CONDITION MONITORING OF MARINE ELECTRICAL GENERATORS FOR IMPROVED MAINTENANCE LEADING TO INCREASED RELIABILITY AND AVAILABILITY

    The stator winding short circuit faults in Brushless Synchronous Generator (BLSG) used for onboard power generation in ships may lead to catastrophic failures and back out. Hence, it is important to develop Condition Monitoring (CM) techniques for the BLSG to improve its reliability and …

    nus Repository record for CONDITION MONITORING OF MARINE ELECTRICAL GENERATORS FOR IMPROVED MAINTENANCE LEADING TO INCREASED RELIABILITY AND AVAILABILITY (opens in a new tab) Download file for CONDITION MONITORING OF MARINE ELECTRICAL GENERATORS FOR IMPROVED MAINTENANCE LEADING TO INCREASED RELIABILITY AND AVAILABILITY (opens in a new tab)

  17. Electromagnetic flux monitoring for detecting faults in electrical machines

    … parameters used for fault detection, such as stator phase current and circulating currents between the parallel branches of the stator winding. The following faults were investigated in this thesis: a turn-to-turn short circuit in the stator winding; rotor cage-related faults (breakage of …

    aalto Repository record for Electromagnetic flux monitoring for detecting faults in electrical machines (opens in a new tab)