Results 1 to 20 of 95 for “"steel column"”
-
EXPERIMENTAL AND NUMERICAL FAILURE ANALYSIS OF DEEP STEEL COLUMN SECTIONS
… limit state of collapse is approached. Exterior columns in perimeter steel moment-resisting frame structures that are exposed to strong earthquakes experience bending moment demands with high levels of axial load due to overturning. Deep wide flange sections can be used as exterior columns to …
-
Semi rigid connections and their influence on steel column behaviour.
… rotational behaviour of practical beam- to-column connections, as used in steel frames, has also been reviewed. This data is found to be a non- linear function of connection deformation. Methods of mathematically modelling connection data have been reviewed and an improved representation …
-
Investigating multi-axis long-duration blast response of steel column sections
… to drag-sensitive structural elements such as steel columns. A number of recent large-scale industrial accidents have highlighted the potential for multiple detonations to occur that can cause long-duration blasts to successively interact with structures, and constituent column elements from …
-
Simple Models for Estimating the Rotational Stiffness of Steel Column-to-Footing Connections
… loads from the superstructure to the foundation, steel column-to-footing connections have received little attention in research. Though shallow embedded connections are typically characterized as pinned, studies have shown that they exhibit significant rotational stiffness. The objective of this …
-
Development of Dissipative Steel Column-Base Connections for Steel Moment-Resisting Frames under Seismic Loading
In capacity-designed steel moment resisting frames (MRFs), column base connections feature a strong-base/weak-column design philosophy. Prior studies on fixed-end wide flange steel columns featuring seismically compact cross sections subjected to coupled axial load and lateral drift demands suggest …
-
Dynamic Behaviour of a Fixed-end Square Hollow Section Steel Column Subjected to Wind Flow
Steel lattice structures are widely used in the structural engineering. These structures are light in weight and usually all structural elements are exposed to wind. This forms that fact that wind loads are highly dependent of the cross-section of structural elements. Although there are several …
-
A study of the behavior of a composite concrete and steel column under the influence of combined axial and flexural loads
In a theoretical bean-column analysis it is necessary to know the value of the effective modulus of elasticity in order to compute the critical buckling load of the member in compression. The composite specimens of this study had a slenderness ratio, 1/k « 62.7 and were not in the Euler range of …
-
The behaviour and design of demountable connections to promote the reduction and reuse of structural steel in steel and composite buildings
… and performance of the conventional steel column connections under various loading conditions through the developed finite element model, with which the accuracy of the behaviour prediction for the steel column connections can be significantly improved. The concept of demountability …
-
Estudo de bases de pilares metálicos pelo método dos elementos finitos
The most used design methods for steel column bases present hypotheses to the stress distribution on their connection components. The goal of this work was to analyze steel column bases through a finite element computational program in order to obtain more accurately the behavior of their …
-
Load capacity of hybrid precast column
… is to evaluate the behaviour of hybrid precast columns that are formed by embedding structural steel column section at the ends of precast concrete columns. The purpose of this project is also to investigate the factors that govern the load transfer mechanisms from the embedded structural steel …
-
Unbonded Pre-tensioned Bridge Columns with Hybrid Fiber-Reinforced Concrete Shells
… than in previously tested reinforced concrete columns (Pang et al. 2008, Haraldsson et al. 2012). Two columns were designed and tested in the University of Washington Structural Laboratory. In the plastic-hinge region of the columns a very ductile concrete shell was added. The shell was made of …
-
Earthquake-induced collapse of steel moment resisting frames with conventional and high performance steel columns
… reduced the earthquake-induced collapse risk in steel frame buildings designed in seismic regions. Experiments suggest that the steel column behaviour may be significantly compromised due to member and local geometric instabilities, thereby increasing the associated collapse risk and likelihood …
-
Rotational Stiffness Models for Shallow Embedded Column-to-Footing Connections
Shallow embedded steel column connections are widely used in steel buildings; however, there is insufficient research about this connection type to understand the actual rotational stiffness that the connection provides. Shallow embedded steel columns are when a steel column is anchored to the …
-
Finite element modelling and evaluation of welding procedures in high strength (450 Mpa : 65 Ksi) W - shape column assemblies
The use of high strength steel has become more frequent in modern steel construction due to the increasing demand for taller buildings and longer spans. High strength stocky steel columns are often used as part of a building's primary lateral load resisting system. During the fabrication of welded …
-
Ligação mista viga-pilar resistente a momento
The use of steel and concrete composite structures in Brazil has been increased in the last decades. However, there are only a few references about the behavior of beam-to-column composite moment connections. These connections are used in moderate to high-rise buildings where the …
-
An assessment of the performance of semiconductor gas sensors as gas chromatographic detectors.
… samples. A 1.5 meter x 4 millimeter stainless steel column packed with active carbon type 208C (60-72 B.S.mesh) at 40 G was used; to separate hydrogen, carbon monoxide and methane using purified air as carrier gas. Optimum operating conditions for the T.G.S.711 sensor: heater voltage 6.5 volts …
-
Prekybos centro Midaugas Šiauliuose statybos [projektas /
… the structural part, 14.50 m between the support steel truss and 6.50 m long steel column is calculated. In the technological part, a technological card for floor tiles has been prepared,, describes the work safety part. In the estimated part, the installation costs of the building components are …