  1. INFLUENCE OF TOPOGRAPHY OF ENDOVASCULAR STENT MATERIAL ON SMOOTH MUSCLE CELL RESPONSE

    Although implantation of endovascular stents for the treatment of coronary and peripheral artery diseases has been one of the most rapidly used medical interventions, significant limitations in terms of a restenosis rate of 10-30% still persists. Neointimal hyperplasia characterized by a phenotypic …

    clemson Repository record for INFLUENCE OF TOPOGRAPHY OF ENDOVASCULAR STENT MATERIAL ON SMOOTH MUSCLE CELL RESPONSE (opens in a new tab)

  2. Application of experimental and analytical approaches in characterizing coronary stents

    … world. The gold-standard treatment for CAD is stent implantation, however, the existing therapy is not sufficient due to many reasons. For instance, in-stent restenosis, biocompatibility, controlled degradation rate, protein adsorption, and adequate endothelialization are still the main …

    qucosa-diss

  3. Computational Investigation of Potential Failure Modes in Arterial Hemodynamic Flowpath

    … in a pristine condition, or attached to the stent. 2-D and 3-D Navier-Stokes based fluid-structure interactive analysis is applied to three different graftartery bypass configurations. Wall shear stress gradients (WSSG) have been considered as the trigger for the abnormal biological processes …

    rit Repository record for Computational Investigation of Potential Failure Modes in Arterial Hemodynamic Flowpath (opens in a new tab)

  4. Development of Biodegradable Composite Materials for Coronary Stents

    Stents based on poly(L-lactic acid), PLLA, are very prominent in the field of biodegradable stents but a disadvantage of PLLA is its relative brittleness. Cardiologists have noted the occurrence of strut fracture during deployment of balloon expandable PLLA stents. Blends of PLLA and …

    auckland-ms Repository record for Development of Biodegradable Composite Materials for Coronary Stents (opens in a new tab)

  5. Engineering the “Pluripotency” of Zr-based Bulk Metallic Glasses as Biomedical Materials

    … has brought up new opportunities for biomaterials. Research in this dissertation was focused on exploring multiple biomedical functionalities of Zr-based BMGs over a wide spectrum, combining materials and biological characterizations, through experimental and computational approaches. …

    utk-theses Repository record for Engineering the “Pluripotency” of Zr-based Bulk Metallic Glasses as Biomedical Materials (opens in a new tab)

  6. Application of discrete multiphysics to fluid-structure-interaction simulation of vascular flows

    … fluid (blood) and solid (arterial wall and stent) within a coronary artery implanted with a metal stent. In the case of aortic valve, the effects of various calcification stages (ranging from mild to severe) on cardiac output were simulated and evaluated. It was found that increasing levels …

    birmingham Download PDF for Application of discrete multiphysics to fluid-structure-interaction simulation of vascular flows (opens in a new tab)

  7. DEVELOPMENT OF A DYNAMIC <i>IN VITRO<i> MODEL OF A STENTED BLOOD VESSEL TO EVALUATE THE EFFECTS OF STENT STRUT MATERIAL SELECTION AND SURFACE COATING ON SMOOTH MUSCLE CELL RESPONSE

    … done in conjunction with the deployment of a stent. Stent deployment helps hold the vessel open following the local injury caused by balloon inflation and prevents elastic recoil and subsequent negative remodeling. Stenting has been shown to significantly reduce restenosis rates from …

    clemson Repository record for DEVELOPMENT OF A DYNAMIC <i>IN VITRO<i> MODEL OF A STENTED BLOOD VESSEL TO EVALUATE THE EFFECTS OF STENT STRUT MATERIAL SELECTION AND SURFACE COATING ON SMOOTH MUSCLE CELL RESPONSE (opens in a new tab)

  8. Development of adenoviral and miRNA eluting stents

    … and involves the deployment of an intravascular stent into the diseased vessel, which acts as a permanent scaffold that mechanically re-widens the vessel. However, despite the prolific use of intravascular stents within the clinic, there are significant problems associated with this …

    glasgow Download PDF for Development of adenoviral and miRNA eluting stents (opens in a new tab)

  9. Formulation and testing of biodegradable polymeric coating on zinc wires in cardiovascular stent application

    … loss of mechanical integrity of the endovascular stent and to improve the healing process of the diseased vascular site. The PLLA coating was used in this study because of its biodegradability, favorable degradation rate, hydrophobicity and favorable mechanical properties. Static immersion, …