Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 10 of 10 for “"stent technology"”.

  1. Application of experimental and analytical approaches in characterizing coronary stents

    … world. The gold-standard treatment for CAD is stent implantation, however, the existing therapy is not sufficient due to many reasons. For instance, in-stent restenosis, biocompatibility, controlled degradation rate, protein adsorption, and adequate endothelialization are still the main …

    qucosa-diss

  2. Low-power temperature sensing system for biomedical applications

    … thesis, we focus on an electro-thermally active stent technology for management of in-stent restenosis (i.e., re-narrowing of artery at the stented site). Various studies reporting hyperthermia treatments of restenosis through stent heating have shown promising results, i.e., moderate local …

    ubc Repository record for Low-power temperature sensing system for biomedical applications (opens in a new tab) Download PDF for Low-power temperature sensing system for biomedical applications (opens in a new tab)

  3. Development and Evaluation of a Nanomatrix Coated Stent Using a Vascular Sheet With Atherosclerosis Model

    While cardiovascular stent technology has considerable advances, there are hurdles to overcome due to the dysfunctional stented arteries which fail to maintain vascular homeostasis. Current stent designs ignored the significance of promoting functional artery healing (pro-healing). Therefore, we …

    uab Repository record for Development and Evaluation of a Nanomatrix Coated Stent Using a Vascular Sheet With Atherosclerosis Model (opens in a new tab)

  4. Design and Manufacture of a Biodegradable Ureteral Stent

    Approximately 92,000 ureteral stents are implanted every year to maintain urine flow after treatment of kidney stones, kidney transplants, and urinary incontinence. However, current ureteral stents have several downsides that include encrustation, urgency due to the proximal curl pressing on the …

    clemson Repository record for Design and Manufacture of a Biodegradable Ureteral Stent (opens in a new tab)

  5. Self-assembled Monolayer-Based Surface Modification of Stainless Steel for Oriented Antibody Immobilization: Towards Improved Stent Biocompatibility

    Stenting is a common surgical procedure for the widening of arteries narrowed by atherosclerosis. The stent is an expandable cylindrical scaffold that is implanted within the lumen of arteries and is commonly constructed from stainless steel. Despite the benefits of stenting, post-stent …

    toronto-retro Repository record for Self-assembled Monolayer-Based Surface Modification of Stainless Steel for Oriented Antibody Immobilization: Towards Improved Stent Biocompatibility (opens in a new tab)

  6. Mechanical analysis and simulation of the nitinol ring-stent : assessing the radial strength, fatigue safety and compaction strains

    … conditions are often treated with endovascular stent-graft implants: flexible polymer conduits supported by metallic structures. Vascutek, a company based near Glasgow, is unique in designing and producing stent-grafts based on the ‘ringstent’ technology: the structural annular components being …

    strathclyde Repository record for Mechanical analysis and simulation of the nitinol ring-stent : assessing the radial strength, fatigue safety and compaction strains (opens in a new tab)

  7. Outcomes and monocyte response in percutaneous coronary intervention

    … disease. Despite continuous refinement of the stent-technology and significant improvement of patient outcomes over the years, stent failure continues to be its Achille’s heal. Inflammation, the foundation of coronary artery disease, also appears to be related to the small but lifelong risk …

    east-anglia Download PDF for Outcomes and monocyte response in percutaneous coronary intervention (opens in a new tab)

  8. Koronare Herzerkrankung: Innovative Techniken und Strategien der interventionellen Koronardiagnostik und -therapie

    … am Schwein werden mittels Micro-CT-Analyse präexistente Kollateralgefäße und mittels MRT deren funktionelle Bedeutung nachgewiesen. Ein minimalinvasives Tiermodell mit perkutan interventionell induziertem kontrollierten CTO-artigen Koronargefäßverschluss und seriellen Verlaufsbeobachtungen am …

    fu-berlin Repository record for Koronare Herzerkrankung: Innovative Techniken und Strategien der interventionellen Koronardiagnostik und -therapie (opens in a new tab)

  9. Alternative approaches to the prevention of coronary In-stent restenosis

    … failure rate of 50% at 10 years. Intracoronary stents, used for PCI are limited by the restenosis or thrombosis of stented vessel segments, phenomena that also confer significant morbidity and mortality. Vein graft disease (VGD) and in-stent restenosis (ISR)/thrombosis share similar pathological …

    glasgow Download PDF for Alternative approaches to the prevention of coronary In-stent restenosis (opens in a new tab)