Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 86 for “"stented"”.

  1. Blood Flow Simulation in Stented Vessels and Flow Reversal Conditions

    Hemodynamics is one of the major factors involved in the development of cardiovascular diseases and adverse events associated with endovascular stent implantation such as in-stent restenosis and thrombosis. The first part of this work is dedicated to the imaging of stent deployment in graft tubes …

    houston Repository record for Blood Flow Simulation in Stented Vessels and Flow Reversal Conditions (opens in a new tab)

  2. Laminar and Transitional Flow disturbances in Diseased and Stented Arteries

    … (DPIV), (b) Complex geometric effects of stented arteries with emphasis on its design parameters is investigated using CFD, Also (c) a novel method to improve the accuracy of velocity gradient estimation in the presence of noisy flow fields such as in DPIV where noise is inherently present …

    vt Repository record for Laminar and Transitional Flow disturbances in Diseased and Stented Arteries (opens in a new tab)

  3. Application Of In Vivo Flow Profiling To Stented Human Coronary Arteri

    The study applies in vivo technique for profiling hemodynamics and wall shear stress (WSS) distribution in human coronary arteries. The methodology involves fusion of 2D Intra Vascular Ultra Sound and Bi-plane angiograms to reproduce the 3D arterial geometry. This geometry is then used in a …

    ucf Repository record for Application Of In Vivo Flow Profiling To Stented Human Coronary Arteri (opens in a new tab)

  4. The Haemodynamics of a Stented Arteriovenous Fistula through Experiments and Flow Modelling

    … conducted. The trajectory of the flow in the stented case was funnelled within the stent encapsulated region which in turn, contained the disturbed flow within the stent lumen while mitigating the generation of turbulence. Consequently, the distribution of adverse wall shear stress (WSS) in …

    unsw Repository record for The Haemodynamics of a Stented Arteriovenous Fistula through Experiments and Flow Modelling (opens in a new tab)

  5. COUPLED FLUID-CHEMICAL COMPUTATIONAL MODELING OF ANTICOAGULATION THERAPIES IN A STENTED ARTERY

    Stent thrombosis is a major complication that occurs after the placement of stents in the coronary artery through balloon angioplasty, associated with severe medical conditions with a high risk of mortality. The common treatment for stent thrombosis is to provide patients with anticoagulant and …

    jhu Repository record for COUPLED FLUID-CHEMICAL COMPUTATIONAL MODELING OF ANTICOAGULATION THERAPIES IN A STENTED ARTERY (opens in a new tab)

  6. Stented Artery Biomechanics: A Computational and In Vivo Analysis of Stent Design and Pathobiological Response

    Vascular stents have become a standard for treating atherosclerosis due to distinct advantages in trauma and cost with other surgical techniques. Unfortunately, the therapy is hindered by the risk of a new blockage (termed restenosis) developing in the treated artery. Clinical studies have …

    tamu Repository record for Stented Artery Biomechanics: A Computational and In Vivo Analysis of Stent Design and Pathobiological Response (opens in a new tab)

  7. Computational Evaluation of Shear Stress and Restenosis in Stented Coronary Arteries Using Optical Coherence Tomography

    … data, and normalized to WSS in the proximal unstented region. Stent-to-vessel area ratios were less in PE and XP than NO (0.24±0.04 and 0.21±0.03 vs. 0.34±0.04, respectively; P<0.05). The difference between the NO and XP was significant. PS normalized stent-induced low WSS area/stent length was …

    marquette Repository record for Computational Evaluation of Shear Stress and Restenosis in Stented Coronary Arteries Using Optical Coherence Tomography (opens in a new tab)

  8. In situ aortic root in vitro testing of the stented and stenless porcine aortic heart valves

    … time software to analyze the fluid dynamics of stented and unstented porcine bioprostheses. Thirteen Shethigh Porcine valves were tested in the Pulse Duplicator System for this study which include 7 - 25mm valve, 4 stented and 3 stentless, and 6 - 23mm valves, 3 stented and 3 stentless. Results …

    njit Repository record for In situ aortic root in vitro testing of the stented and stenless porcine aortic heart valves (opens in a new tab)

  9. Evaluating Wall Shear Stress Indices to Uncover Stimuli for Restenosis and Malapposition in Stented Coronary Arteries

    … data, and normalized to WSS in the proximal unstented region. The change in lumen area (CLA) from post-stenting to follow-up was calculated using co-registered OCT pairs (469 pairs), corresponding to OCT imaging locations. The WSS results were compared with CLA using two-step cluster analysis. …

    marquette Repository record for Evaluating Wall Shear Stress Indices to Uncover Stimuli for Restenosis and Malapposition in Stented Coronary Arteries (opens in a new tab)

  10. Studies of Stented Arteries and Left Ventricular Diastolic Dysfunction Using Experimental and Clinical Analysis with Data Augmentation

    Cardiovascular diseases are among the leading causes of deaths worldwide, but the fluid mechanics of many of these conditions and the devices used to treat them are only partially understood. This goal of this dissertation was to develop new experimental techniques that would enable translational …

    vt Repository record for Studies of Stented Arteries and Left Ventricular Diastolic Dysfunction Using Experimental and Clinical Analysis with Data Augmentation (opens in a new tab)

  11. Η χρήση των εμποτισμένων με φάρμακα μεταλλικών ενδοπροθέσεων στον ουρητήρα πειραματικού μοντέλου

    … of the luminal and intraluminal condition of the stented ureters. Histopathologic examination of the stented ureters embedded in glycol-methacrylate was performed. Results: Hyperplastic reaction was present in both stent types. BMSs in 7 porcine ureters were completely obstructed while porcine …

    greece Repository record for Η χρήση των εμποτισμένων με φάρμακα μεταλλικών ενδοπροθέσεων στον ουρητήρα πειραματικού μοντέλου (opens in a new tab)

  12. Evaluation of Acute and Chronic Lesions in Percutaneous Coronary Intervention

    … to demonstrate its effectiveness on human stented vessels obtained at autopsy. A total of seven cases are demonstrated where our analysis techniques were able to elucidate the pathogenesis of the host response and identify the specific cause of the complications with the stented vessel seen …

    tamu Repository record for Evaluation of Acute and Chronic Lesions in Percutaneous Coronary Intervention (opens in a new tab)

  13. The role of altered cyclic strain patterns on proliferation and apoptosis of vascular smooth muscle cells - implications for in-stent restenosis

    … where BASMC were cultured inside a perfused stented Sylgard mock artery under physiological levels of strain. Vascular SMC proliferation was significantly increased (+40%) and apoptosis decreased within the stented region in comparison to the more compliant upstream and downstream non-stented …

    dcu Download PDF for The role of altered cyclic strain patterns on proliferation and apoptosis of vascular smooth muscle cells - implications for in-stent restenosis (opens in a new tab)

  14. Quantifying Hemodynamic Changes Caused by Stenting of Coronary Bifurcation Lesions Using Realistic Computational Fluid Dynamics Models

    … it well-suited for studying hemodynamics in stented coronary bifurcations. The objective of this work is to develop methods whereby geometric models of stented coronary bifurcations can be created and simulated with CFO using realistic boundary conditions. Initially, idealized models were …

    marquette Repository record for Quantifying Hemodynamic Changes Caused by Stenting of Coronary Bifurcation Lesions Using Realistic Computational Fluid Dynamics Models (opens in a new tab)

  15. Alleviating the adverse haemodynamics of arteries treated with drug-eluting stents without compromising drug uptake

    … – defined as the reduction in diameter of a stented vessel by more than 50% – still persists in up to 20% of drug-eluting stent patients. Furthermore, blood clots persist on the surfaces of drug-eluting stents in up to 0.8% of patients even after more than 30 days have passed since stent …

    unsw Repository record for Alleviating the adverse haemodynamics of arteries treated with drug-eluting stents without compromising drug uptake (opens in a new tab)

  16. Numerical Simulation of Plaque Growth and Rupture in Arteries by Using Immersed Boundary-Lattice Boltzmann Method

    … of this work is to study and understand how a stented artery behaves and how it affects the local blood flow dynamics. To do so, the simplified one-, two- and three- dimensional models are developed in this thesis. In these models, the dynamics of the solid and the fluid, as well as their …

    unsw Repository record for Numerical Simulation of Plaque Growth and Rupture in Arteries by Using Immersed Boundary-Lattice Boltzmann Method (opens in a new tab)

Page 1 of 5