Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 207 for “"storey building"”.
-
Behaviour of Inelastic Multi-Storey Building Frames Subjected to Strong Ground Motions
… to the dynamic response of inelastic multi-storey building frames subjected to strong ground motions. The main purpose is to investigate, both analytically and experimentally, those aspects of the dynamic response characteristics which are of importance in aseismic design. In the first part …
-
Model updating of a 48-storey building in Vancouver using ambient vibration measurements
This study focused on the One Wall Centre, a 48-storey high building located in downtown Vancouver, British Columbia. It is currently the highest building in Vancouver, and it is the only structure in the region that makes use of tuned liquid column dampers to reduce vibrations due to wind. The …
-
Dynamic characteristics of a 30 storey building during construction detected from ambient vibration measurements
The dynamic response of building structures to earthquakes has become an issue in the province of British Columbia because of increased awareness of the seismic hazard in this region. While there is a great deal of knowledge about structural dynamics, the majority of this knowledge is based on …
-
Daugiabutis gyvenamasis namas Vijoliuose /
In final Bachelor’s project “Multi-storey building in Vijoliai” I have made a project of multi-storey building which is located in Žalioji st. 1a, Vijoliai, Siauliai dist. The building is designed with five-storey and basement, has one staircase unit and elevator. There are 4 flats in each 1st – …
-
An Exploration of how Energy-Related Ecosystem Services Provided by Extensive Green Roofs in Alberta may be Quantified Using Life Cycle Assessment Tools
… indoor temperature regulation of commercial buildings. The objective is to quantify this service from three perspectives; energy, environmental impacts and cost. A representative green roof, the AEI, is used along with roof evaluation modules. A 0.4 °C indoor temperature increase in winter …
-
Συστήματα περιφερειακής ανάπτυξης: προς μια βιώσιμη περιβαλλοντικά και ενεργειακά θεώρηση της χωρικής ανάπτυξης
… approach is applied on the grounds of Greece’s building stock energy efficiency project. The energy efficiency caused by the energy protection of the Greek residences’ cell (using insulation and proper windows) is calculated by computerized simulation of a typical one-storey building as well as …
-
Vaikų darželis ,,Pasaka" Architektų g /
… work is designed kindergarten ,,Pasaka”- a two-storey building with a total floor area of 1358,72 m2. Public building is designed in Architektu st., Siauliai. It is equipped with separate rooms for 90 children (six groups of 15 children). The ground floor has three nursery groups, kitchen block, …
-
On the earthquake generated response of torsionally unbalanced buildings.
… response of torsionally unbalanced “shear” buildings to horizontally directed earthquake excitation. Attention is confined to analytical models that have linearly elastic, viscously damped responses. The investigation involves three separate analyses: Firstly, in a preliminary study, the …
-
Optimization of rectangular plane frames using box's complex method.
… with the minimum cost design of a multi-storey building. The building consists of rectangular steel plane frames which are evenly spaced and support identical floors and a roof. The frame spacing, the column positions within the frame, and the number of intermediate beams spanning between …
-
Krovininių – lengvųjų automobilių serviso Kuršėnuose statybos projektas /
… service in Kuršėnai construction project. Two-storey building with a total area of 1434,15 m2. It is planned to repair the engines, chassis and bodies of trucks and cars in the object, and it is planned to install a computer diagnostic stand. Location – Kuršėnai city. The project consists of …
-
Characteristics of Reinforced and Post-tensioned Concrete Slabs during Construction
… terms of safety and economy, especially in multi-storey buildings for which post- tensioned slab structures are very common. However, general practices for formwork systems, including removal times, in both post-tensioned and reinforced concrete buildings, have to comply with the standards …
-
Wind gust pressures on buildings
Design wind loads for building structures are usually based on the simplified concept of a steady wind, and the model tests used to determine design pressure coefficients are made in low-turbulence, constant velocity wind tunnels.A statistical approach is required for a more realistic analysis of …
-
Energy based seismic design of a multi-storey hybrid building : timber-steel core walls
… timber-steel core wall system for use in multi-storey buildings in high seismic regions. This hybrid system combines Cross Laminated Timber (CLT) panels with steel plates and connections to provide the required strength and ductility to core walled buildings. The system is first derived from …
-
Seismic Fragility Assessment for Reinforced Concrete High -Rise Buildings
… of the fragility assessment of an existing 54-storey building with a dual core wall system. The set of rigorously derived probabilistic fragilities are the first published for high-rise RC buildings, thus they fill an important void in regional earthquake impact assessment in Metropolitan …
-
Memories of a Wall in Old Montreal – Reassembling the Puzzle of the Past
An existing five storey building in Old Montreal has an exposed wall revealing a remarkable history of contributions from at least five building states, the earliest of which was constructed in the eighteenth century. Using the framework of semiotics as proposed by Charles Saunders Peirce …
Page 1 of 11