Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 10 of 10 for “"strain gauging"”.

  1. Large scale pullout testing of geosynthetics

    … used in the program of testing. A technique of strain gauging the geosynthetic test specimen has been developed. Variables examined in the program of testing were type of geosynthetic and confining stress. Measurement of pullout force, pullout displacement, horizontal pressure on front face of …

    ubc Repository record for Large scale pullout testing of geosynthetics (opens in a new tab) Download PDF for Large scale pullout testing of geosynthetics (opens in a new tab)

  2. An investigation into the behaviour of various sized fibre reinforced plastic beams

    … flexural loading. The distribution of stress and strain through the depth of glass fibre reinforced composite beams were investigated using three experimental techniques, namely: interlaminar strain gauging, photoelastic coating, and thermal emission (SPATE) . Experimental results indicated that …

    cent-lancashire Download PDF for An investigation into the behaviour of various sized fibre reinforced plastic beams (opens in a new tab)

  3. Development of a lead spring u-bolt load transducer : part of an onboard weighing system for off-highway log trucks

    … was divided into two stages: preliminary strain measurement with a loaded off-highway tractor, and finite element modelling of a U-bolt from the tractor’s leaf spring suspension. A preliminary measurement test was carried out to identify potential suspension components that could act as …

    ubc Repository record for Development of a lead spring u-bolt load transducer : part of an onboard weighing system for off-highway log trucks (opens in a new tab) Download PDF for Development of a lead spring u-bolt load transducer : part of an onboard weighing system for off-highway log trucks (opens in a new tab)

  4. A Novel Wearable Device for Distributed Sensing of Elastomeric Strain Gauges

    … rigid counterparts. They can conform to and strain match human skin and sense for inputs such as touch/pressure, electrical potentials, chemical interactions, and mechanical deformation in a distributed manner [2]. In the present work, a comprehensive design process is presented for a …

    clemson Repository record for A Novel Wearable Device for Distributed Sensing of Elastomeric Strain Gauges (opens in a new tab)

  5. Evaluation of Stress and Fatigue in Femoral Hip Implants

    … validated the FEA within an error of 1.2%. Strain gauging validation was also accurate and had an error of 3.4%. For fatigue, the stress-life theory, along with the Goodman method, were used to predict the fatigue life cycle of a femoral implant. A comparison between the predicted and …

    denver Repository record for Evaluation of Stress and Fatigue in Femoral Hip Implants (opens in a new tab)

  6. An investigation of the methodologies for biomechanical assessment of stroke rehabilitation

    … their reliability explored. The feasibility of strain gauging an AFO for measuring orthotic loads was ascertained and the use of the uncontrolled manifold (UCM) approach to verify centre of mass (CM) control during gait was investigated. These methods were validated with tests on able-bodied …

    strathclyde Repository record for An investigation of the methodologies for biomechanical assessment of stroke rehabilitation (opens in a new tab)

  7. Skeletal Biomechanics and Response to Mechanical Load: A Comparative Approach in the Mouse and Chukar Partridge

    … A healthy skeleton adapts to the bone tissue strain profile and magnitude of loads it experiences on a daily basis in order to maintain reasonable safety factors. In skeletal diseases, such as osteoporosis, a bone’s ability to adapt and maintain structural integrity in response to increased …

    purdue-thes Repository record for Skeletal Biomechanics and Response to Mechanical Load: A Comparative Approach in the Mouse and Chukar Partridge (opens in a new tab)

  8. Einfluss der Skelettreifung auf die Knochenmasse und adaptive Knochenantwort bei mechanischer Belastung in Sost KO/ Sclerostin-defizienten Mäusen

    … littermate mice were subjected to two weeks of strain matched in vivo axial-compressive loading of the left tibia (+900με at the tibial midshaft, determined by strain gauging). The right tibia served as internal control. Static and dynamic trabecular and cortical bone parameters were assessed …

    fu-berlin Repository record for Einfluss der Skelettreifung auf die Knochenmasse und adaptive Knochenantwort bei mechanischer Belastung in Sost KO/ Sclerostin-defizienten Mäusen (opens in a new tab)

  9. Cancellous Bone Adaptation To Non-Invasive Mechanical Loading In The Murine Tibia

    … -11.5 N in both males and females from in vivo strain gauging. This peak load resulted in similar peak cancellous tissue strains of ~-2400 [mu][epsilon]in females and ~-2100 [mu][epsilon]. Following 2 weeks of tibial compression, male and female mice increased cancellous bone mass 73% in the …

    cornell Repository record for Cancellous Bone Adaptation To Non-Invasive Mechanical Loading In The Murine Tibia (opens in a new tab)

  10. Optimalizace vlastností snímače vektoru kontaktní síly

    Cílem této diplomové práce je optimalizace vlastností snímače vektoru kontaktní síly, jehož prototyp je v současné době navrhnut. Princip senzoru je založen na měření přetvoření aktivní části snímače pomocí tří tenzometrů, následné identifikaci velikosti a vektoru zatěžující síly pomocí neuronové …

    brno-tech Repository record for Optimalizace vlastností snímače vektoru kontaktní síly (opens in a new tab)