Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 24 for “"stray capacitance"”.

  1. Effect of valve element characteristics, stray capacitance and voltage harmonics on surge arrester diagnostics

    … character of the valve elements, the effect of stray capacitance and voltage harmonics. A method is proposed to assess the discerning ability of the diagnostic indicator due to hysteresis character of the valve elements and voltage harmonics. Effect of stray capacitance on the diagnostic …

    manitoba Repository record for Effect of valve element characteristics, stray capacitance and voltage harmonics on surge arrester diagnostics (opens in a new tab)

  2. A Four Terminal Instrumentation System for the Measurement of Complex Bioelectric Impedance

    … system at frequencies of 10 Hz to 100 KHz. Stray capacitance caused errors which necessitated calibration and correction of the data by substituting the load with a low capacitance known - value resistor and simulated electrode impedance before and after each study. In addition, load …

    marquette Repository record for A Four Terminal Instrumentation System for the Measurement of Complex Bioelectric Impedance (opens in a new tab)

  3. Ultra-high impedance superconducting circuits

    … maximum total inductance is still limited by the stray capacitance of the chain, which results in parasitic self-resonances. This stray capacitance is unnecessarily large in most circuits due to the high dielectric constant of silicon or sapphire substrates used. Here, we explore a regime of …

    maryland Repository record for Ultra-high impedance superconducting circuits (opens in a new tab)

  4. An analysis of parasitic capacitances in ioimpedance spectroscopy and their impact on impedance measurements

    … Existing work models this hook with a stray capacitance in parallel with an existing tissue circuit model. While this model certainly produces a hook artifact, it does not account for the presence of electrodes in the circuit model. This thesis expands on this model to include the …

    alabama Repository record for An analysis of parasitic capacitances in ioimpedance spectroscopy and their impact on impedance measurements (opens in a new tab)

  5. A Novel Flexible Distributed Pressure Sensing Strip for a Urethral Catheter

    … substrates and copper electrodes. To remove the stray influence of urethral tissues which create fringe capacitance that can lead to significant errors, a reference fringe capacitance measurement sensor is incorporated on the strip and the whole sensor area is actively shielded in a Faraday cage …

    umn Repository record for A Novel Flexible Distributed Pressure Sensing Strip for a Urethral Catheter (opens in a new tab)

  6. Three-Phase Dual Active Bridge Converter: Design Considerations and Planar Transformer Design

    … of transformer losses, leakage inductance and stray capacitance provides a guideline for transformer design. The operating principle of three-phase DAB converter is presented and the closed form expression of zero-voltage-switching (ZVS) condition, current stress of switching devices and DC …

    mcmaster Repository record for Three-Phase Dual Active Bridge Converter: Design Considerations and Planar Transformer Design (opens in a new tab)

  7. Testing and Measurement in a High Voltage and High dv/dt Environment Demonstrated in a 10 kV SiC Based MMC Phase-Leg

    … this mostly involves reducing the stray capacitance. A Modular Multilevel Converter (MMC) submodule is used to demonstrate the sensor and testing setup. The voltage sensor and its impact on the control of the MMC will be stressed. Finally, suggestions for the design of medium …

    ut-knoxville Repository record for Testing and Measurement in a High Voltage and High dv/dt Environment Demonstrated in a 10 kV SiC Based MMC Phase-Leg (opens in a new tab)

  8. Progress Towards the Quantum Limit: High and Low Frequency Measurements of Nanoscale Structures

    … is shown that for the expected inductances and stray capacitances, at an operating frequency of 1.25 GHz, the RF-SET is expected to have a usable half-bandwidth of 175-200 MHz and a charge sensitivity on the order of 10^(−5) e/√Hz. A fabricated RF-SET device is cryogenically cooled and used to …

    queens Repository record for Progress Towards the Quantum Limit: High and Low Frequency Measurements of Nanoscale Structures (opens in a new tab)

  9. Analysis of Optoelectronic Device for QKD applications

    … an on-chip quenching resistor which minimises stray capacitance effects<br/>commercially known as a negative feedback avalanche diode (NFAD).

    bristol Repository record for Analysis of Optoelectronic Device for QKD applications (opens in a new tab) Download PDF for Analysis of Optoelectronic Device for QKD applications (opens in a new tab)

  10. MICROWAVE ACTIVE INDUCTOR ANALYSIS AND DESIGN

    … inductor has an intrinsic resistance and a stray capacitance, which will severely affect its quality factor and available frequency band in the circuit design. In this project, some novel microwave active inductors and the designed circuit configurations are presented. Their quality factors, …

    nus Repository record for MICROWAVE ACTIVE INDUCTOR ANALYSIS AND DESIGN (opens in a new tab) Download file for MICROWAVE ACTIVE INDUCTOR ANALYSIS AND DESIGN (opens in a new tab)

  11. Online condition monitoring of HV cable circuits

    … because they cannot account for the influence of stray capacitance. This has led to the development of a new method of calibration based on frequency response analysis and the use of simulation model. Results obtained are in good agreement with values determined using a terminal injection …

    soton Download PDF for Online condition monitoring of HV cable circuits (opens in a new tab)

  12. BILAYER LIPID MEMBRANE (BLM) INTEGRATION INTO MICROFLUIDIC PLATFORMS WITH APPLICATION TOWARD BLM-BASED BIOSENSORS

    … applied for long-term testing. Second, stray capacitance inherent to traditional test rigs limits the temporal response leading, for example, to poor resolution in determining fast ion channel translocation events. Lastly, BLM testing is done within a single site format thus limiting …

    maryland Repository record for BILAYER LIPID MEMBRANE (BLM) INTEGRATION INTO MICROFLUIDIC PLATFORMS WITH APPLICATION TOWARD BLM-BASED BIOSENSORS (opens in a new tab)

  13. Scalable Bundle Design for Massively Parallel Neuronal Recordings <i>In Vivo</i>

    … because of the non-intrusive dimensions, low stray capacitance, and enhanced surface impedance of the electrodes, as well as the high signal to noise amplification of the camera electronics. <br></br><br></br> Here the construction of a system to record neural activity is described and its …

    the-open-u Download PDF for Scalable Bundle Design for Massively Parallel Neuronal Recordings <i>In Vivo</i> (opens in a new tab)

  14. Feedback controlled electromigration for the fabrication of point contacts and noise measurement applications

    … by combining an inductor with unavoidable stray capacitance to form a resonant LC circuit. Noise measurement tests with a photodiode-LED pair at room temperature demonstrated the ability to resolve shot noise down to 5e-26 A^2/Hz. This corresponds to the shot noise of 155 nA through a …

    queens Repository record for Feedback controlled electromigration for the fabrication of point contacts and noise measurement applications (opens in a new tab)

  15. Process monitoring, modeling, and control of plasma etch systems

    … the importance of accurate characterization of stray capacitance and inductance in the power delivery system. Plasma parameters of impedance, delivered power, and sheath thickness were computed using simple equivalent circuit models for the plasma discharge. Measurement of fundamental and …

    texas Repository record for Process monitoring, modeling, and control of plasma etch systems (opens in a new tab) Restricted access

  16. A study on micro-patterning of polypyrrole using micro-electro-discharge machining

    … Machining tests with varying voltages and capacitances indicates that the use of larger capacitances at 60 V does not enhance EDM removal much unlike typical μEDM of metals, whereas the use of larger voltages with stray capacitance shows significant enhancement; a hypothesis to explain …

    ubc Repository record for A study on micro-patterning of polypyrrole using micro-electro-discharge machining (opens in a new tab) Download PDF for A study on micro-patterning of polypyrrole using micro-electro-discharge machining (opens in a new tab)

  17. Interaction of laser beam with solids

    … laser beam could be explained in terms of a capacitance effect. The electrostatic coupling between a collector and any neighbouring metal part, because of the stray capacitance between them, will be of considerable importance when a rapid voltage change of the collector is concerned.</p> …

    oxford Repository record for Interaction of laser beam with solids (opens in a new tab)

  18. Development of an electrical impedance tomograph for complex impedance imaging

    … source type system, whilst able to reduce stray capacitance, creates other more significant errors due to circuit matching; future development in semiconductor device technology may help to overcome this difficulty. It was identified that contact impedances together with the effective …

    southwales Repository record for Development of an electrical impedance tomograph for complex impedance imaging (opens in a new tab) Download PDF for Development of an electrical impedance tomograph for complex impedance imaging (opens in a new tab)

  19. High-speed electrochemistry using ultramicroelectrodes

    … account non-idealities in the electrode such as stray capacitance and resistance of the electrode itself. This study indicates that time constants in the tens of nanoseconds are probably the shortest attainable using the conventional setups for ultramicroelectrode experiments. (f) A discussion of …

    uiuc Repository record for High-speed electrochemistry using ultramicroelectrodes (opens in a new tab)

Page 1 of 2