Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 21 for “"streaking artifacts"”

  1. Quantification of Oxygen Saturation of Venous Vessels Using Susceptibility Mapping

    … approaching 90% of the expected value. Also, streaking artifacts associated with high susceptibility structures such as veins are obvious in the reconstructed SM. To further improve susceptibility quantification and reduce the streaking artifacts in the SMs, we proposed a threshold-based …

    mcmaster Repository record for Quantification of Oxygen Saturation of Venous Vessels Using Susceptibility Mapping (opens in a new tab)

  2. The use of computed tomography images in Monte Carlo treatment planning

    … (CT) images into MC geometry files. Metal streaking artifacts and their effect on MC dose calculations are first studied. A correction algorithm is applied to artifact-corrupted images and dose errors due to density and tissue mis-assignment are quantified in a phantom and a patient study. …

    mcgill Repository record for The use of computed tomography images in Monte Carlo treatment planning (opens in a new tab)

  3. Advanced research into moving target imaging using multistatic radar

    … from issues of incorrect positions (spatial) and streaking artifacts (temporal). Using the Cheney/Borden procedure, we investigated combining the spatial, temporal, and spectral aspects of real and synthetic aperture radar images. We code the Cheney/Borden algorithm to include the target velocity, …

    nps Repository record for Advanced research into moving target imaging using multistatic radar (opens in a new tab)

  4. Improving the Reliability and Accessibility of CT Perfusion Imaging in Acute Ischemic Stroke

    … fewer x-ray projections but at the expense of streaking artifacts in the reconstructed image. In Chapter 4, we demonstrated that CTP is relatively insensitive to streaking artifacts and that radiation dose could be reduced by 50 to 66% compared to routine levels with sparse-view CTP. Low-dose …

    uwo Repository record for Improving the Reliability and Accessibility of CT Perfusion Imaging in Acute Ischemic Stroke (opens in a new tab)

  5. Iterative CT reconstruction from few projections for the nondestructive post irradiation examination of nuclear fuel assemblies

    … from few projections and create severe streaking artifacts. In this thesis, conventional algorithms are reviewed, and new algorithms are developed for reconstructions of the nuclear fuel assemblies using few projections. CT reconstruction from few projections falls into two categories: …

    must-thes Repository record for Iterative CT reconstruction from few projections for the nondestructive post irradiation examination of nuclear fuel assemblies (opens in a new tab)

  6. A deep learning pipeline for real-time palliative radiotherapy of spine metastasis

    … network (GAN)-based network for reducing streaking artifacts and a cycle-consistent GAN for CBCT-based sCT generation. Subsequent phases involve a three-stage network for vertebral segmentation, using heatmap regression techniques for coarse localization and fine identification of …

    carleton Repository record for A deep learning pipeline for real-time palliative radiotherapy of spine metastasis (opens in a new tab)

  7. Real-Time Computed Tomography-based Medical Diagnosis Using Deep Learning

    … dose generate low-quality images with noise and streaking artifacts. Therefore we develop a deep learning-based CT image enhancement algorithm for improving the quality of low-dose CT images. Our algorithm uses a convolution neural network called DenseNet and Deconvolution network (DDnet) to …

    vt Repository record for Real-Time Computed Tomography-based Medical Diagnosis Using Deep Learning (opens in a new tab)

  8. Quantitative Susceptibility Mapping (QSM) Reconstruction from MRI Phase Data

    … Still, the reconstructed QSM images suffer from streaking artifacts and underestimate the measured susceptibility of deep gray matter, veins, and other high susceptibility regions. This thesis proposes a structurally constrained Susceptibility Weighted Imaging and Mapping (scSWIM) method to …

    ohiolink Repository record for Quantitative Susceptibility Mapping (QSM) Reconstruction from MRI Phase Data (opens in a new tab)

  9. Improving ion beam therapy treatment planning for metal implants by using dual-energy CT scanning

    … in the range of the voxel size of 0.6 mm. Streaking artifacts around the samples were minor for aluminum and titanium. For materials with Z ≥ 26, severe artifacts could be observed. The samples were investigated with Mega Voltage Computed Tomography to compare DECT with this rivaling …

    heid-thes Repository record for Improving ion beam therapy treatment planning for metal implants by using dual-energy CT scanning (opens in a new tab)

  10. Deep Learning for Quantitative Susceptibility Mapping Reconstruction

    … susceptibility estimation errors that appear as streaking artifacts in the QSM, especially in massive hemorrhagic regions. Because current QSM techniques struggle to generate reliable QSM, the clinical translation of QSM is greatly hindered. Recently, deep learning (DL) has achieved …

    marquette Repository record for Deep Learning for Quantitative Susceptibility Mapping Reconstruction (opens in a new tab)

  11. An approach to map soil texture class on the Iowan Erosion Surface

    … than the model that excluded those covariates. Streaking artifacts present in the directional distance rasters suggest that methodological refinement is needed. At the PSF level, maps that included legacy data as a supplement to the new dataset returned lower RMSE and higher CCC statistics …

    iastate Repository record for An approach to map soil texture class on the Iowan Erosion Surface (opens in a new tab)

  12. Development and Performance of a Sparsity-Exploiting Algorithm for Few-View Single Photon Emission Computed Tomogrpahy (SPECT) Reconstruction

    … and TV weighting parameters reduced noise and streaking artifacts, while decreasing spatial resolution. The reconstructed images demonstrate that the reconstruction algorithm introduces low-frequency artifacts in the presence of noise, but eliminates streak artifacts due to angular …

    marquette Repository record for Development and Performance of a Sparsity-Exploiting Algorithm for Few-View Single Photon Emission Computed Tomogrpahy (SPECT) Reconstruction (opens in a new tab)

  13. Supervised and Self-Supervised Learning for Accelerated Medical Imaging

    … on image reconstruction as the undersampling artifacts start to manifest. This dissertation exploits the emerging technique, deep learning, to tackle the problem of image reconstruction from undersampled data in both CT and MRI applications. This dissertation explores learned reconstruction in …

    arizona-thes Repository record for Supervised and Self-Supervised Learning for Accelerated Medical Imaging (opens in a new tab)

  14. Transitioning Statistical Iterative Dual-Energy CT Reconstruction to the Clinic: Artifact Reduction and Machine Learning-Based Acceleration

    … have been observed. These include motion artifacts resulting from patient movement during sequential DECT scans, artifacts caused by missing or corrupted measurements, and clinically unacceptable time-to-solution even if multiple acceleration techniques have been exploited. Sequential …

    wustl Repository record for Transitioning Statistical Iterative Dual-Energy CT Reconstruction to the Clinic: Artifact Reduction and Machine Learning-Based Acceleration (opens in a new tab)

  15. Development of a 3D radial MR Imaging sequence to be used for (self) navigation during the scanning of the fetal brain in utero

    … at a lower base resolution, thus reducing streaking artifacts and improving the accuracy of image co-registrations. Finally, the methods developed were applied to two fetal scans. The radial sequence was shown to be more motion-robust than an equivalent Cartesian sequence. The minimum …

    cape-town Repository record for Development of a 3D radial MR Imaging sequence to be used for (self) navigation during the scanning of the fetal brain in utero (opens in a new tab)

  16. A Novel Method to Improve Quantitative Susceptibility Mapping with an Application for Measuring Changes in Brain Oxygen Saturation in the Presence of Caffeine and Diamox

    … arterial phase thanks to the reduced ringing artifacts. Lastly, a novel approach to improve the susceptibility mapping results was introduced and utilized to monitor the changes in venous oxygen saturation levels as well as the changes in oxygen extraction fraction instigated by the …

    mcmaster Repository record for A Novel Method to Improve Quantitative Susceptibility Mapping with an Application for Measuring Changes in Brain Oxygen Saturation in the Presence of Caffeine and Diamox (opens in a new tab)

  17. Quantitative Susceptibility Mapping in Human Brain: Short Echo Timing, Thin Slab, and Non-harmonized Multisite Applications

    … resolution and echo-timings, and minimizing streaking artifacts. To conclude, this thesis proposed new methods to minimize the time burden of including QSM in clinical protocols by utilizing phase from a common MPRAGE volumetric acquisition to examine iron-rich regions and microbleeds, or by …

    alberta Repository record for Quantitative Susceptibility Mapping in Human Brain: Short Echo Timing, Thin Slab, and Non-harmonized Multisite Applications (opens in a new tab)

  18. Accurate Low-Dose Iterative CT Reconstruction from Few Projections using Sparse and Non-Local Regularization Functions

    … (2) introduce additional noise and (3) leads to streaking artifacts in the reconstructed images. Therefore, efficient reconstruction algorithms have to be found which can compensate the resulting image quality degradation. The X-ray model can be solved analytically by Filtered Backprojection …

    heid-diss Repository record for Accurate Low-Dose Iterative CT Reconstruction from Few Projections using Sparse and Non-Local Regularization Functions (opens in a new tab)

  19. Use of Multiple Imaging Views for Improving Image Quality in Small Animal MR Imaging Studies

    … can degrade image quality with blurring and artifacts. In many small animal imaging studies, multiple imaging views are already obtained as part of the normal workflow but the information taken from one view is not generally combined with that from another view. The main objective of this …

    ohiolink Repository record for Use of Multiple Imaging Views for Improving Image Quality in Small Animal MR Imaging Studies (opens in a new tab)

Page 1 of 2