Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 29 for “"sumps"”

  1. Characterization of Drilling Waste Sumps in Northern Alberta, Canada

    Sumps, or earthen pits, are often used to store and dispose of solid and liquid drilling wastes from oil and gas drilling operations; the contents of these sumps can vary depending on the region and the depth of the related drilling project(s). The variation includes chemical composition of the …

    alberta Repository record for Characterization of Drilling Waste Sumps in Northern Alberta, Canada (opens in a new tab)

  2. Integrity of Drilling Waste Sumps, Mackenzie Delta Area, NT

    n 1960–2005, over 220 sumps were constructed in Mackenzie Delta and adjacent uplands to contain used drilling muds within permafrost. Past records were compared with current field data at 12 sites to investigate egress of contaminants from the sumps under a warming climate. Electromagnetic surveys …

    carleton Repository record for Integrity of Drilling Waste Sumps, Mackenzie Delta Area, NT (opens in a new tab)

  3. Use of standard sumps for suspended sediment removal from stormwater

    There are many standard sumps in urban stormsewer systems that may qualify as a best management practice to pre-treat stormwater runoff by removing suspended sediment from the water. However, no data on the effectiveness of sediment removal and required maintenance schedules of standard sumps …

    umn Repository record for Use of standard sumps for suspended sediment removal from stormwater (opens in a new tab)

  4. The optimisation of baffle arrangements for minimal sediment washout in standard stormwater sumps.

    … the ecology of those areas. Standard stormwater sumps are a reliable and cost-effective solution to trap and retain sediment within stormwater drainage systems for manual removal. However, under high flowrate and fine sediment conditions, the effectiveness of standard sumps drastically decreases. …

    ukzn Repository record for The optimisation of baffle arrangements for minimal sediment washout in standard stormwater sumps. (opens in a new tab)

  5. Effects of salt concentration on freeze-thaw dynamics in column experiments: Implications for contaminant transport in warming permafrost

    Drilling-mud sumps are used for the disposal of drilling fluid from exploratory oil and gas wells in northern regions. Sumps are vulnerable to permafrost thaw and subsequent mobilization of once-frozen contaminants, including freezing-point depressants such as salts. Overall, the long-term …

    carleton Repository record for Effects of salt concentration on freeze-thaw dynamics in column experiments: Implications for contaminant transport in warming permafrost (opens in a new tab)

  6. Tundra vegetation recovery on 30 year-old seeded and unseeded drilling mud sumps in the Mackenzie River Delta region, NWT

    … sites is present in the form of drilling mud sumps, which are mounds of disturbed tundra that contain frozen drilling-wastes. One to two years after the wells were decommissioned some of the sites were seeded with non-native grass species and fertilized to test whether these treatments could …

    sask Repository record for Tundra vegetation recovery on 30 year-old seeded and unseeded drilling mud sumps in the Mackenzie River Delta region, NWT (opens in a new tab)

  7. Permafrost Drilling-Waste Sump Integrity in the Sahtú Region, central Mackenzie Valley, NT, Canada.

    … evaluates the integrity of five drilling-waste sumps containing contaminants in the subsurface, whether in frozen or unfrozen ground. We assess the extent to which permafrost in these drilling-sumps continues to fulfill its intended containment function. Our initial inventory of sump presence …

    alberta Repository record for Permafrost Drilling-Waste Sump Integrity in the Sahtú Region, central Mackenzie Valley, NT, Canada. (opens in a new tab)

  8. Stormwater treatment with the SAFL Baffle: debris and non-standard sump testing

    … (0.15 m) deep scale model sump. All of the sumps were equipped with the SAFL Baffle, and were evaluated using two metrics: 1. How well the system captures sediment at low flow rates (Removal Efficiency Testing) 2. How well the system retains the previously captured sediment at high flow …

    umn Repository record for Stormwater treatment with the SAFL Baffle: debris and non-standard sump testing (opens in a new tab)

  9. Hydrodynamic separator sediment washout testing.

    … washout of previously deposited sediments in the sumps of hydrodynamic separators under high flow conditions during infrequent storm events, sediment washout testing methods using mass balance were developed for both controlled field testing and laboratory testing. The developed testing methods …

    umn Repository record for Hydrodynamic separator sediment washout testing. (opens in a new tab)

  10. Strategies to control bacteriophage infection in a threonine bioprocess

    … in the samples collected at various areas (sumps, odour scrubber, process water, and soil) around the plant for 16 weeks. High levels of phages were found in the sumps and this was identified as the source of infection. Samples collected were grouped together according to their source. The …

    dut Repository record for Strategies to control bacteriophage infection in a threonine bioprocess (opens in a new tab)

  11. Effects of load shifting on water quality in a large potable water network

    … established that it would be possible to use the sumps of the water treatment works to achieve the desired load shift. By using the sumps of the WTW, a load shift can be done without stopping any process in the WTW with the exception of disinfection at the Booster Pump Stations (BPS), where the …

    nwu-za Repository record for Effects of load shifting on water quality in a large potable water network (opens in a new tab)

  12. Effects of Froude Scaling on Velocity-Induced Vortices in Physical Models

    … in hydraulic structures such as dams and pump sumps. They can be detrimental to the operation and efficiency of these structures. The purpose of this work is to examine the change in vortex behavior at differing physical model scales. This was done using four identical experiments built at …

    utahstate Repository record for Effects of Froude Scaling on Velocity-Induced Vortices in Physical Models (opens in a new tab)

  13. Effluent treatment and its re-use for the Kriel Power Station

    … sump and pumped to the high level ash water sumps where a percentage is used for the ashing system while most water remains within the sump. There is a continuous intake of raw water to the cooling water (CW) system due to water losses through evaporation, effluent, leaks etc. Due to water …

    nwu-za Repository record for Effluent treatment and its re-use for the Kriel Power Station (opens in a new tab)

  14. Biological and chemical hazards in water-mix metalworking fluids and mists

    … at different levels within both the used MWF sumps and the mist samples taken. Conclusions: This study demonstrates that it is likely contaminants and constituents of MWF become airborne during machining processes. However, further research is required to determine the quantities of such …

    sheffield-hallam Repository record for Biological and chemical hazards in water-mix metalworking fluids and mists (opens in a new tab)

  15. Modelling and measurement of soil gas flow

    … developed were: o The flow rates generated by 'sumps', o Where the flow from a sump comes from, and hence its associated energy costs. o A technique for measuring the leakage of the substructure of a house (under some special conditions), o The ease of air flow through different hard core …

    ucl Repository record for Modelling and measurement of soil gas flow (opens in a new tab)

  16. TRIBOLOGICAL AND RHEOLOGICAL CHARACTERISTICS OF WATER BASED LUBRICANTS FOR ADVANCED BEARING APPLICATIONS

    … practice requires two different fluid systems (sumps, pumps, pipes, and filters) adding cost, weight and complexity. Compared to combustion engines, EVs fluids (oils and coolants) do not require similarly extreme high temperature capabilities. Thus, the opportunity exists to consider new fluids …

    ohiolink Repository record for TRIBOLOGICAL AND RHEOLOGICAL CHARACTERISTICS OF WATER BASED LUBRICANTS FOR ADVANCED BEARING APPLICATIONS (opens in a new tab)

  17. Optimal Startup of Cryogenic Air Separation units: Modeling, Simulation, Optimization, and Control

    … vapor flow discontinuities, flow liquid out of sumps and reboilers, and opening and closing valves. Other types of discontinuities accounted for include the change in the number of phases of streams. These discontinuities are approximated with smoothing formulations, using mostly hyperbolic …

    mcmaster Repository record for Optimal Startup of Cryogenic Air Separation units: Modeling, Simulation, Optimization, and Control (opens in a new tab)

  18. A paleolimnological assessment of recent environmental changes in lakes of the western Canadian Arctic

    … storm-surge damage. Finally, lakes impacted by sumps used to dispose of the drilling by-products of hydrocarbon exploration exhibit distinct water chemistry, and are particularly elevated in potassium and chloride, which form a major component of some drilling fluids. Related to this, a …

    queens Repository record for A paleolimnological assessment of recent environmental changes in lakes of the western Canadian Arctic (opens in a new tab)

  19. Chemical characterisation of landfill leachate and its potential mobility through the Cape Flats sand

    … management strategy, such as leachate collection sumps, should be implemented. This exercise demonstrated the use of LEACHM as an alternative means of predicting leachate discharge from landfill sites.

    cape-town Repository record for Chemical characterisation of landfill leachate and its potential mobility through the Cape Flats sand (opens in a new tab)

Page 1 of 2