Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 50 for “"supply temperature"”

  1. Akureyri’s district heating system : an optimization study: optimization of supply temperature

    … energy per capita. The largest use of low temperature geothermal energy is for space heating in large districts of towns. The water sent to consumers in Akureyri town in north Iceland is a mix of hot geothermal water and water returning from users’ radiators. The goal of this work is to …

    akureyri Repository record for Akureyri’s district heating system : an optimization study: optimization of supply temperature (opens in a new tab)

  2. BUILDING AUTOMATION SYSTEM

    … designed to maintain a constant chilled water supply temperature regardless of the cooling load and outdoor conditions. However, the work input per ton of refrigeration will be higher when compared to the evaporator supplying a higher chilled water supply temperature to meet the cooling load …

    nus Repository record for BUILDING AUTOMATION SYSTEM (opens in a new tab)

  3. A Revolving Reference Odometer Circuit for BTI-Induced Frequency Fluctuation Measurements under Fast DVFS Transients and Reconfigurable Feed Forward MUX PUF Design

    The frequency shift due to fast Bias Temperature Instability (BTI) related fast Dynamic Voltage and Frequency Scaled (DVFS) stress-recovery effects were measured using a high resolution revolving reference silicon odometer. It uses eight fresh/reference ring oscillators (ROSCs), which alternately …

    umn Repository record for A Revolving Reference Odometer Circuit for BTI-Induced Frequency Fluctuation Measurements under Fast DVFS Transients and Reconfigurable Feed Forward MUX PUF Design (opens in a new tab)

  4. Preliminary Investigation into Solar Thermal Combi-system Performance

    … number of tank nodes, hydronic-floor supply temperature, and hydronic-floor R-value. Of these, the solar collector parameters and the hydronic-floor supply temperature had the greatest impact on the overall system performance.

    queens Repository record for Preliminary Investigation into Solar Thermal Combi-system Performance (opens in a new tab)

  5. Low Delta-T Syndrome Diagnosis and Correction for Chilled Water Plants

    … input variables were chilled water leaving temperature, condenser water entering temperature and water flow. A detailed study of the TES tank was made to ensure that the proposed changes would enable the TES tank to provide cooling for the airport, particularly during the summer months from …

    tamu Repository record for Low Delta-T Syndrome Diagnosis and Correction for Chilled Water Plants (opens in a new tab)

  6. Technology Mapping, Design for Testability, and Circuit Optimizations for NULL Convention Logic Based Architectures

    … analysis, inherent robustness against power-supply, temperature, and process variations, reduced energy consumption, less noise and EMI emission, and easy design reuse are some of the benefits of these circuits. NULL Convention Logic (NCL) is one of the mainstream asynchronous logic design …

    arkansas Repository record for Technology Mapping, Design for Testability, and Circuit Optimizations for NULL Convention Logic Based Architectures (opens in a new tab)

  7. AN ASYMPTOTIC ANALYSIS OF SPONTANEOUS IGNITION OF HYDROGEN JETS

    … as functions of slot width, flow rate, and temperatures of the hydrogen jet and ambient air. Two scenarios are examined: a cool jet flowing into a hot ambient and a hot jet flowing into a cool ambient. For both scenarios, ignition is favored with an increase of either the ambient temperature …

    maryland Repository record for AN ASYMPTOTIC ANALYSIS OF SPONTANEOUS IGNITION OF HYDROGEN JETS (opens in a new tab)

  8. Semi-empirical model of convection heat transfer at windows and blinds near floor diffusers for use in building energy modeling

    … for various blind angles, HVAC regimes, surface temperatures, and window sizes are examined. Results show that convection at window and blind surfaces is highly dependent on blind angle, supply temperature and flow rate, moderately dependent on room-supply air temperature difference and HVAC …

    texas Repository record for Semi-empirical model of convection heat transfer at windows and blinds near floor diffusers for use in building energy modeling (opens in a new tab)

  9. Influence of thermal expansion in district heating network on initiation of leakage points

    … and leakages. Thesis was limited to study only supply temperature gradients in Espoo area district heating network. Interviews of specialists from other district heating networks were performed. Operational and leakage data analysis started from identifying and collecting relevant data. By …

    chalmers Repository record for Influence of thermal expansion in district heating network on initiation of leakage points (opens in a new tab)

  10. Διερεύνηση ενεργειακών και περιβαλλοντικών επιπτώσεων από τη χρήση αντλιών θερμότητας αέρα-νερού σε συστήματα θέρμανσης

    … statistical processing of hourly outdoor air temperature data from 50 meteorological stations of the National Observatory of Athens was conducted for the period 2010–2019. From these data, a temperature database suitable for energy calculations according to the EN14825 standard was developed. …

    greece Repository record for Διερεύνηση ενεργειακών και περιβαλλοντικών επιπτώσεων από τη χρήση αντλιών θερμότητας αέρα-νερού σε συστήματα θέρμανσης (opens in a new tab)

  11. Interplanting of a deficient soybean stand

    … germination and emergence are moisture, oxygen supply, temperature, and diseases. All of these factors can reduce the emergence percentage and increase the time for emergence of soybeans. In the past management options for a deficient soybean stand consisted of leaving the existing stand till …

    missouri Repository record for Interplanting of a deficient soybean stand (opens in a new tab)

  12. Implementation of Energy Efficiency Measures in Existing Building Commissioning & Methodology for Supply Air Temperature Resets

    … six building types with 551 implemented EEMs. Supply air temperature resets, schedule optimizations, and fan speed resets had the highest average implementation rates for all building types with overall rates of 60.7%, 49.3%, and 44.3% respectively. Further analysis of implementation by system …

    tamu Repository record for Implementation of Energy Efficiency Measures in Existing Building Commissioning & Methodology for Supply Air Temperature Resets (opens in a new tab)

  13. A method for the seasonal performance rating of a residential water heating heat pump

    … conditions as well as the municipal water supply temperature. As heat pumps are designed and built by different manufacturers, differences in terms of the sub-components used and their specifications are common. As a result, each heat pump model must be tested to determine its energy saving …

    nwu-za Repository record for A method for the seasonal performance rating of a residential water heating heat pump (opens in a new tab)

  14. Computational modelling and exergetic analysis of a District Cooling system

    … profile, under hot and cold ambient wet-bulb temperature scenarios, each tested at chilled-water supply temperature setpoints of 6°C, 8°C, and 10°C. Chillers and cooling towers accounted for at least 95% of total exergy destruction, with electrical power consumption identified as the dominant …

    uniandes Repository record for Computational modelling and exergetic analysis of a District Cooling system (opens in a new tab)

  15. Optimization of HVAC control system strategy using two-objective genetic algorithm

    … supervisory control strategy set points, such as supply air temperature, supply duct static pressure, chilled water supply temperature, supply C02 concentration (or minimum outdoor ventilation), reheat (or zone supply air temperature), and zone air temperature are optimized with respect to energy …

    ets-quebec

  16. Seasonal Thermal Energy Storage in Buried Water Tanks for Single Detached Houses

    … such as variable speed pumping, radiant floor supply temperature modulation, and storage setpoints are explored, among others. In regard to sizing, for the house under study, it is shown that solar fractions over 90% require relatively large (and potentially costly) STES tanks (30m^3). However, …

    carleton Repository record for Seasonal Thermal Energy Storage in Buried Water Tanks for Single Detached Houses (opens in a new tab)

  17. Modelling of district heating grid

    … generated the following parameters: the customer supply temperature and the grid volume flowrate are calculated to illustrate how the generation units are operated to meet the customers’ heating demand. Furthermore, heat loss is estimated as it’s an essential parameter to the feasibility of …

    chalmers Repository record for Modelling of district heating grid (opens in a new tab)

  18. Empirical validations of the DOE-2.1E building simulation software for daylighting and economizer controls

    … reheat power required for the space. The system temperatures, cooling heat transfer rates, and supply temperature were comparable to the empirical parameters. Comparisons for the economizer control were only made for the system. In general, the predictions for parameters like outside airflow …

    iastate Repository record for Empirical validations of the DOE-2.1E building simulation software for daylighting and economizer controls (opens in a new tab)

  19. The Effect of Thermal Energy Transport on the Performance of (SEMI) Floating Ring Bearing Systems for Turbochargers

    … of predictions for the inner film pressure and temperature distributions against archival test data for a journal bearing with two supply grooves. The tool is next used to analyze the performance characteristics of a (semi) floating ring bearing in a turbocharger application, as well as the …

    tamu Repository record for The Effect of Thermal Energy Transport on the Performance of (SEMI) Floating Ring Bearing Systems for Turbochargers (opens in a new tab)

Page 1 of 3