Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 29 for “"surface coil"”.

  1. Utilization of NMR surface coil techniques to study muscle fatigue

    … into two parts: (a) design and evaluation of NMR surface coils of various configurations, and assessment of a preliminary clinical protocol, (b) optimization of the technique by normalizing the results with respect to the cross-sectional area of the human upper arm, and to the various parameters …

    ubc Repository record for Utilization of NMR surface coil techniques to study muscle fatigue (opens in a new tab) Download PDF for Utilization of NMR surface coil techniques to study muscle fatigue (opens in a new tab)

  2. The Koch Snowflake RF Surface Coil: Exploring the Role of Fractal Geometries in 23Na-MRI

    … of MRI development, the radio frequency (RF) coil. Fractal antennas have been used in telecommunication systems for years, and are generally exploited for their compact nature, allowing for the same performance of a larger antenna, in a smaller space. They have also been shown to be capable of …

    mcmaster Repository record for The Koch Snowflake RF Surface Coil: Exploring the Role of Fractal Geometries in 23Na-MRI (opens in a new tab)

  3. Evolution of methodology for obtaining hydrogen magnetic resonance spectra of thyroid nodules in vivo

    … use of STEAM localization and a multi-ring surface coil offered the SNR advantages of a surface coil with homogeneous volume localization, comparable to that of volume coils. With an appropriate multi-ring surface-coil design and optimal placement with respect to the thyroid or tumor, …

    manitoba Repository record for Evolution of methodology for obtaining hydrogen magnetic resonance spectra of thyroid nodules in vivo (opens in a new tab)

  4. Digital communication link for MR Surface Coils

    … Resonance Imaging (MRI). Recent advances in surface coil technology require a large amount of copper cables, which are heavy and cumbersome to handle and introduce a potential hazard to the patient due to induced currents on the surface. This work is aimed at eliminating copper cables from …

    marquette Repository record for Digital communication link for MR Surface Coils (opens in a new tab)

  5. Current Balancing Coaxial-Coils For Magnetic Resonance Imaging

    MRI surface coil arrays extend the field-of-view and improve the signal-to-noise ratio (SNR) compared to individual coils. However, inductive coupling between coils will degrade the SNR and can introduce image artefacts. The most common approach to array-coil decoupling combines coil-overlapping …

    bristol Repository record for Current Balancing Coaxial-Coils For Magnetic Resonance Imaging (opens in a new tab) Download PDF for Current Balancing Coaxial-Coils For Magnetic Resonance Imaging (opens in a new tab)

  6. Application of surface coils to in-vivo studies using ³¹P-NMR spectroscopy

    … into two parts: testing and evaluation of some surface coils, and application of the surface coils to in-vivo studies. In particular, the localization properties of surface coils were examined and optimized using the highest performance coil geometry and wire. Application of the surface coil …

    ubc Repository record for Application of surface coils to in-vivo studies using ³¹P-NMR spectroscopy (opens in a new tab) Download PDF for Application of surface coils to in-vivo studies using ³¹P-NMR spectroscopy (opens in a new tab)

  7. The Application of Electromagnetic Theory in Microwave Therapy and Magnetic Resonance Imaging

    … of low SNR in an MRI system. A vertical phased coil array which consists of a number of vertically stacked surface coils is proposed. The SNR increase is firstly explained in theory with the conclusion that SNR can be increased by increasing the number of coils in the array provided that the …

    nus Repository record for The Application of Electromagnetic Theory in Microwave Therapy and Magnetic Resonance Imaging (opens in a new tab) Download file for The Application of Electromagnetic Theory in Microwave Therapy and Magnetic Resonance Imaging (opens in a new tab)

  8. Study of B1 Field Distribution for Loop Coil with Different Bending Angles at 3T

    … the interest in mechanically flexible RF coils has grown rapidly in the MR community. The main benefit expected in comparison to rigid coils is a higher achievable signal-to-noise ratio (SNR) in case of strong variations of the targeted anatomy across patients. However the high SNR is due …

    buffalo Repository record for Study of B1 Field Distribution for Loop Coil with Different Bending Angles at 3T (opens in a new tab)

  9. Development of novel radiofrequency coils for hyperpolarized magnetic resonance imaging

    … by the performance of Radio-Frequency (RF) coils, devices that transmit and receive the electromagnetic (EM) fields which interact with the patient to generate the MR signal.</p> <p>X-nuclear MRI, investigating non-proton ‘X-’ nuclei, provides unique metabolic information in vivo. Compared …

    oxford Repository record for Development of novel radiofrequency coils for hyperpolarized magnetic resonance imaging (opens in a new tab)

  10. Fractal-based magnetic resonance imaging coils for 3T Xenon imaging

    … results in MR imaging. The traditional RF surface coils used in MR imaging exhibit an inhomogeneous field, leading to reduced image quality. For the last few decades, fractal-shaped antennas have been used to optimize the performance of antennas for radiofrequency systems. Although widely …

    mcmaster Repository record for Fractal-based magnetic resonance imaging coils for 3T Xenon imaging (opens in a new tab)

  11. Characterization of L-band Resonators and Relaxation Times of SOₓ- Radicals at X-band

    … Volume resonators enclose samples, while surface coil resonators allow imaging of larger subjects. For in vivo studies, L-band frequencies are commonly used because they offer a good balance between signal-to-noise ratio (S/N) and the ability to penetrate tissue. Rapid Scan (RS) EPR at …

    denver Repository record for Characterization of L-band Resonators and Relaxation Times of SOₓ- Radicals at X-band (opens in a new tab)

  12. Power Divider Miniaturization with a Variable Load

    … system is able to scan with both the body coil and surface coil at the same time due to a technology called simultaneous acquisition, which uses a 4-port power divider, typically a quad hybrid. This functions at 127.72 MHz. The goal is to replicate this function at 1.5 Tesla field strength …

    marquette Repository record for Power Divider Miniaturization with a Variable Load (opens in a new tab)

  13. Advanced RF Hardware Solutions for Improved Imaging Performance and Safety in Ultra-High and Very-Low-Field MRI

    … each regime presents unique challenges in RF coil design, affecting imaging quality, patient safety, and system accessibility. This dissertation introduces a series of innovations in antenna structures, multi-channel array configurations, safety enhancement techniques, and material-based …

    buffalo Repository record for Advanced RF Hardware Solutions for Improved Imaging Performance and Safety in Ultra-High and Very-Low-Field MRI (opens in a new tab)

  14. PET/MR imaging of hypoxic atherosclerotic plaque using 64Cu-ATSM

    … the attenuation effect of the carotid surface coil into the MR attenuation correction _-map to correct for photon attention.In the long term, this imaging strategy has the potential to help identify patients at risk for cardiovascular events, guide therapy, and add to the understanding …

    wustl Repository record for PET/MR imaging of hypoxic atherosclerotic plaque using 64Cu-ATSM (opens in a new tab)

  15. Quantitative Molecular MRI of Intervertebral Disc Degeneration

    … MRI, we engineered a custom radio-frequency (RF) surface coil for sodium MRI of human lumbar spine on a 7 T MRI scanner. Cross-correlation of the MT MRI, T1ρ MRI and sodium MRI data with the corresponding Pfirrmann grade revealed that the relative collagen density of IVD increases with …

    penn Repository record for Quantitative Molecular MRI of Intervertebral Disc Degeneration (opens in a new tab)

  16. An NMR study of human brain tumours: Phosphorus chemical shift imaging in vivo and high resolution proton spectroscopy of biopsy samples.

    … one dimensional chemical shift imaging with a surface coil was adapted to a 1.5 T Siemens Magnetom imager. The ratios of areas, PDE/ATP and PME/ATP were found to be higher in glioblastomas and astrocytomas than in normal brain. Pi/ATP and PCr/ATP were also high in astrocytomas. The pH of brain …

    ottawa-retro Repository record for An NMR study of human brain tumours: Phosphorus chemical shift imaging in vivo and high resolution proton spectroscopy of biopsy samples. (opens in a new tab)

  17. The role of magnetic field gradients in nuclear magnetic resonance

    … resolution NMR probe was modified with gradient coils (31 mm diameter) for the measurement of translational diffusion and for microscopic imaging, and a larger set of gradient coils (15 cm diameter) was constructed for surface coil diffusion measurements. The magnitudes of the gradients produced …

    ubc Repository record for The role of magnetic field gradients in nuclear magnetic resonance (opens in a new tab) Download PDF for The role of magnetic field gradients in nuclear magnetic resonance (opens in a new tab)

  18. Magnetic Resonance Pulse Sequences for Fluorine-19

    … sequence adaptions. A ^(19)F/^(1)H dual tuned surface coil was purchased from RAPID Biomedical and was used throughout this work. Additionally, pulse sequence modifications to a spin echo sequence and a spoiled gradient echo (called fast low angle shot or FLASH) were made to enable scanning at …

    tamu Repository record for Magnetic Resonance Pulse Sequences for Fluorine-19 (opens in a new tab)

  19. Advanced clinical MRI for better outcome in epilepsy surgery. Focusing on fMRI and prediction of verbal memory decline.

    … to high resolution 3T MRI with and without surface coils. The surface coils were placed over the suspected epileptogenic zone. The efficacy of the coils was assessed and graded in relation to their placement. In papers II, III and IV, a functional MRI (fMRI) paradigm, including both a verbal …

    lund Repository record for Advanced clinical MRI for better outcome in epilepsy surgery. Focusing on fMRI and prediction of verbal memory decline. (opens in a new tab) Download PDF for Advanced clinical MRI for better outcome in epilepsy surgery. Focusing on fMRI and prediction of verbal memory decline. (opens in a new tab)

Page 1 of 2