Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 18 of 18 for “"surface coils"”

  1. Digital communication link for MR Surface Coils

    … Resonance Imaging (MRI). Recent advances in surface coil technology require a large amount of copper cables, which are heavy and cumbersome to handle and introduce a potential hazard to the patient due to induced currents on the surface. This work is aimed at eliminating copper cables from …

    marquette Repository record for Digital communication link for MR Surface Coils (opens in a new tab)

  2. Application of surface coils to in-vivo studies using ³¹P-NMR spectroscopy

    … into two parts: testing and evaluation of some surface coils, and application of the surface coils to in-vivo studies. In particular, the localization properties of surface coils were examined and optimized using the highest performance coil geometry and wire. Application of the surface coil …

    ubc Repository record for Application of surface coils to in-vivo studies using ³¹P-NMR spectroscopy (opens in a new tab)

  3. High-frequency electromagnetic effects and signal-to-noise ratios of surface coils for magnetic resonance imaging

    Surface coils are used in Magnetic Resonance Imaging (MRI) for their high signal-to-noise ratio (S/N) when placed near the region to be imaged. However, their optimization for high field MRI systems is hampered by the lack of understanding of the electromagnetic effects taking place, at high …

    ohiolink Repository record for High-frequency electromagnetic effects and signal-to-noise ratios of surface coils for magnetic resonance imaging (opens in a new tab)

  4. Advanced clinical MRI for better outcome in epilepsy surgery. Focusing on fMRI and prediction of verbal memory decline.

    … to high resolution 3T MRI with and without surface coils. The surface coils were placed over the suspected epileptogenic zone. The efficacy of the coils was assessed and graded in relation to their placement. In papers II, III and IV, a functional MRI (fMRI) paradigm, including both a verbal …

    lund Repository record for Advanced clinical MRI for better outcome in epilepsy surgery. Focusing on fMRI and prediction of verbal memory decline. (opens in a new tab)

  5. The Application of Electromagnetic Theory in Microwave Therapy and Magnetic Resonance Imaging

    … which consists of a number of vertically stacked surface coils is proposed. The SNR increase is firstly explained in theory with the conclusion that SNR can be increased by increasing the number of coils in the array provided that the mutual coupling can be removed. Then the decoupling method is …

    nus Repository record for The Application of Electromagnetic Theory in Microwave Therapy and Magnetic Resonance Imaging (opens in a new tab)

  6. Simulation of Electromagnetic Effects in Magnetic Resonance Imaging

    … time, is employed to analyze the open RF coils in an MRI system. The FD-TD method, known for its ability to handle large and complex geometries, is applied to shielded birdcage coil analysis. Besides studying the field information inside the human head, the RF coil's resonant frequency …

    uiuc Repository record for Simulation of Electromagnetic Effects in Magnetic Resonance Imaging (opens in a new tab)

  7. Fractal-based magnetic resonance imaging coils for 3T Xenon imaging

    … results in MR imaging. The traditional RF surface coils used in MR imaging exhibit an inhomogeneous field, leading to reduced image quality. For the last few decades, fractal-shaped antennas have been used to optimize the performance of antennas for radiofrequency systems. Although widely …

    mcmaster Repository record for Fractal-based magnetic resonance imaging coils for 3T Xenon imaging (opens in a new tab)

  8. Characterization of L-band Resonators and Relaxation Times of SOₓ- Radicals at X-band

    … Volume resonators enclose samples, while surface coil resonators allow imaging of larger subjects. For in vivo studies, L-band frequencies are commonly used because they offer a good balance between signal-to-noise ratio (S/N) and the ability to penetrate tissue. Rapid Scan (RS) EPR at …

    denver Repository record for Characterization of L-band Resonators and Relaxation Times of SOₓ- Radicals at X-band (opens in a new tab)

  9. Geometrically Decoupled Phased Array Coils for Mouse Imaging

    Phased array surface coils offer high SNR over a large field of view. Phased array volume coils have high SNR at the surface and centre of the volume. Most array coil designs typically employ a combination of geometrical and additional techniques, such as isolating preamplifiers for …

    tamu Repository record for Geometrically Decoupled Phased Array Coils for Mouse Imaging (opens in a new tab)

  10. Three-dimensional high-resolution magnetic resonance imaging of the coronary arteries

    … selective RF pulses, employing appropriate surface coils, and possibly utilizing contrast agents should increase the diagnostic capability of 3D MRI of the coronary arteries

    ohiolink Repository record for Three-dimensional high-resolution magnetic resonance imaging of the coronary arteries (opens in a new tab)

  11. Correlation of Magnetic Resonance images of the human temporomandibular joint with gross and microscopic anatomy

    … strength, gradient coil strength, software and surface coils to achieve a high quality image. The small number of false diagnoses in this study were consistently related to underestimation of the pathologic conditions. All of the false diagnoses were false negative's and included an …

    adelaide Repository record for Correlation of Magnetic Resonance images of the human temporomandibular joint with gross and microscopic anatomy (opens in a new tab)

  12. CHARACTERIZATION OF ATHEROSCLEROSIS WITH MAGNETIC RESONANCE IMAGING, CHALLENGES AND VALIDATION

    … Intensity inhomogeneity, which is present when surface coils or intravascular microcoils induce shading artifacts across the data. Artifacts are modeled as a smooth multiplicative bias field with a cubic spline. The cubic spline is optimized to minimize the entropy of the corrected image. …

    ohiolink Repository record for CHARACTERIZATION OF ATHEROSCLEROSIS WITH MAGNETIC RESONANCE IMAGING, CHALLENGES AND VALIDATION (opens in a new tab)

  13. Toward Faster and Quieter MRI

    … the design and optimization of rectangular surface rf coils used for partially parallel imaging. The effect of passive copper shielding applied to the outside of an actively shielded gradient is studied with the aim of substantially reducing induced eddy currents in the cryostat inner bore. …

    ohiolink Repository record for Toward Faster and Quieter MRI (opens in a new tab)

  14. Development and Applications of Efficient Strategies for Parallel Magnetic Resonance Imaging

    … PPA operates by allowing an array of receiver surface coils, positioned around the object under investigation, to partially replace time-consuming spatial encoding which normally is performed by switching magnetic field gradients. Using this strategy, spatial resolution can be improved given a …

    wurz-thes Repository record for Development and Applications of Efficient Strategies for Parallel Magnetic Resonance Imaging (opens in a new tab)

  15. Utilization of NMR surface coil techniques to study muscle fatigue

    … into two parts: (a) design and evaluation of NMR surface coils of various configurations, and assessment of a preliminary clinical protocol, (b) optimization of the technique by normalizing the results with respect to the cross-sectional area of the human upper arm, and to the various parameters …

    ubc Repository record for Utilization of NMR surface coil techniques to study muscle fatigue (opens in a new tab)

  16. Engineering Parallel Transmit/Receive Radio-Frequency Coil Arrays for Human Brain MRI at 7 Tesla

    … done at lower magnetic fields, multiple RF coils are used with independent power inputs. The subsequent distinct RF signals can be manipulated separately, which provides an additional degree of freedom to generate homogeneous B1+-field distributions over large or specific regions in the …

    epfl Repository record for Engineering Parallel Transmit/Receive Radio-Frequency Coil Arrays for Human Brain MRI at 7 Tesla (opens in a new tab)

  17. Subspace Techniques for Parallel Magnetic Resonance Imaging

    … collecting subsampled k-space data from multiple surface coils. The different sensitivity patterns for the various coils provide aspatial encoding and permit recovery from subsampled or otherwise aliaseddata. The smooth coil sensitivities in the image domain multiply with the single image …

    ohiolink Repository record for Subspace Techniques for Parallel Magnetic Resonance Imaging (opens in a new tab)