Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 47 for “"surface detector"”
-
Mass Composition Studies with the Pierre Auger Observatory Surface Detector
… is the Pierre Auger Observatory, a cosmic ray detector in Argentina that covers 3000\,km$^2$ with both a surface array of 1660 water-Cherenkov detectors (with 100\% uptime) and a set of 27 fluorescence telescopes (with 15\% uptime). Its hybrid design uses the smaller, robust data sample …
-
An Optical Fluid Proximity Sensor that Uses a Surface Detector
… This sensor uses IR light and a photo-sensitive surface to detect the presence of fluids contained in, and transported through, general purpose plastic tubing. It is believed that this fluid proximity sensor delivers higher performance and demonstrates greater flexibility than the currently …
-
Mass Composition Studies with the Pierre Auger Observatory Surface Detector
… is the Pierre Auger Observatory, a cosmic ray detector in Argentina that covers 3000\,km$^2$ with both a surface array of 1660 water-Cherenkov detectors (with 100\% uptime) and a set of 27 fluorescence telescopes (with 15\% uptime). Its hybrid design uses the smaller, robust data sample …
-
Hybrid Photon Detection with AugerPrime. Enabling Hybrid Radio and Surface Detector Measurements
… Pierre Auger Observatory, the largest cosmic-ray detector in the world, is being upgraded to AugerPrime to improve the mass-composition sensitivity of its measurements at the highest energies. A key component of the upgrade is the Radio Detector, which complements the Surface Detector array by …
-
Stabilizing energy reconstructions of the surface detector at the Pierre Auger Observatory
… process must be undertaken. For the surface detector, the models utilized for energy reconstruction are empirical approximations of the true particle distribution and thus, different models should return similar energy reconstructions. However, differing models, particularly at high …
-
An Extended Study on the Effects of Incorrect Coordinates on Surface Detector Timing
… for a linear dependence of 1.94 ns.m-1 for surface detectors with an incorrect reading in altitude can be applied. Within the ground plane, we find that the accuracy varies much more dramatically with increased distances, and recommended that any station with a large coordinate discrepancy …
-
The low-energy extension of the Surface Detector Array of the Pierre Auger Observatory
Der Nachweis des Energiespektrums der kosmischen Strahlung mit Oberflächendetektoren erstreckt sich über sechs Größenordnungen der Energie, von $10^{15}$~eV bis zu mehr als $10^{20}$~eV. Es folgt einem Potenzgesetz mit einem Spektralindex $\gamma \simeq 3$ und weist fünf Merkmale auf, die durch …
-
Stability in energy reconstructions of the highest-energy cosmic rays measured by the surface detector of the Pierre Auger Observatory
… this thesis illustrates the instability in surface detector energy reconstructions at low zenith angles via the use of two different, yet valid, lateral distribution functions. These instabilities are shown to result largely from a lack of information constraining the lateral distribution …
-
Exploration of cosmic-ray propagation and thunderstorm models to explain unusual events measured with the surface detector of the Pierre Auger Observatory
The Surface Detector at the Pierre Auger Observatory has recorded events that have an unusually large footprint on the array and lasts 100 times longer than a typical cosmic ray signal. This thesis explores possible models to explain the source of these unusual signals. The proposed models show …
-
Arrival Direction Probabilities of Ultra High Energy Cosmic Rays with the Pierre Auger Observatory and Progress Toward an in-situ Cross-calibration of Auger and Telescope Array Surface Detector Stations
… experiments most data are generated from the surface-detector (SD) array. The TA and Auger experiments use different SD station designs, giving them different sensitivities to extensive air-shower components. We seek to understand and cross-validate these complementary detectors on a hardware …
-
Analysis of simulation and reconstruction methods used by the Pierre Auger Observatory
… The Pierre Auger Observatory is a hybrid detector, containing both a surface detector array, and a fluorescence detector. The surface detector array covers an area of 3000 km², consisting of ∼1600 water Čerenkov detectors, operating with a nearly 100% duty cycle. The Fluorescence detector …
-
The cosmic ray energy spectrum from 1-10 EXA electron volts measured by the Pierre Auger Observatory
… two complementary techniques, a fluorescence detector and a surface detector. The surface detector is 100% efficient for energies above 3 EeV allowing for a flux measurement with low systematic uncertainties. This thesis describes the techniques developed to measure the flux of cosmic rays …
-
Design, calibration, and early results of a surface array for detection of ultrahigh energy cosmic rays
… and large systematic errors. The design of a surface array for the Pierre Auger Observatory, which was intended to resolve these problems, will be discussed, along with its calibration. The surface detector is an array of 1600 water Cherenkov detectors, spaced 1.5 km apart for a total area of …
-
Low energy cosmic ray anisotropies observed using the Pierre Auger observatory.
… Pierre Auger Observatory is a hybrid cosmic ray detector located in the high plains of Argentina. It comprises an array of water-Cherenkov stations overlooked by four fluorescence detector sites and was designed and built for the purpose of studying ultra-high energy cosmic rays (>10¹⁸ eV). Due …
-
Muon data calibration for Auger@Ta
… based on air showers detected using surface detectors from both projects: TA scintillator detectors vs.~Auger Water Cherenkov Detectors (WCD). Auger@TA (Phase 2) consists of a small array of Auger WCD surface detector stations deployed within the existing TA observatory near Delta, …
-
Calibration of the Pierre Auger Observatory fluorescence detectors and the effect on measurements
… the air shower initiated by a cosmic ray: a surface detector composed of an array of more than 1600 water Cherenkov tanks covering 3000 km², and 27 nitrogen fluorescence telescopes overlooking this array. The Cherenkov detectors run all the time and therefore have high statistics on the air …
-
Event Reconstruction with the AugerPrime Upgrade
… which utilises fluorescence telescopes and surface detector stations which measure extensive air showers (EAS) produced by cosmic rays interactions with the atmosphere, allowing Auger to reconstruct the energy, arrival direction and mass composition of UHECRs. Auger has deployed scintillator …
-
SEARCH FOR LONG-LIVED WEAKLY INTERACTING PARTICLES USING THE PIERRE AUGER OBSERVATORY
Data collected with the surface detector array of the Pierre Auger Observatory during the period from January 1, 2004 to March 17, 2015 was examined for evidence of production of long-lived weakly interacting particles in interactions of ultra high energy cosmic rays in the atmosphere. The search …
-
MAXIMUM MUON PRODUCTION DEPTH AND ITS FLUCTUATIONS ABOVE 15 EEV AT THE PIERRE AUGER OBSERVATORY: MASS COMPOSITION AND CONSTRAINTS ON HADRONIC INTERACTION MODELS
The surface detector array of the Pierre Auger Observatory measures the arrival time distribution of particles and it therefore provides indirect information on the longitudinal development of the muonic component of extensive air showers. In this work, the depth at which the muon production is …
Page 1 of 3