Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 167 for “"surface hardness"”.

  1. Surface hardness classification via unmanned aerial vehicles gripper finger deflection

    … (UAV) gripper to determine, upon impact, the hardness of a landing site. We design and fabricate a four finger gripper that uses a rotary component to convert the rotational motion of a servo to the linear motion of the finger assemblies. We functionally test a gripper prototype made from …

    u-pacific Repository record for Surface hardness classification via unmanned aerial vehicles gripper finger deflection (opens in a new tab)

  2. The Effect of Pre-heating on Depth of Cure and Surface Hardness of Resins

    … to evaluate the effect of pre-heating on the surface hardness and depth of cure of composite resins. Factors considered in this study included curing time (10, 20 and 40 seconds), curing temperature (70, 100 and 140 degrees F), curing light type (halogen and LED), and composite type (hybrid …

    loma-linda Repository record for The Effect of Pre-heating on Depth of Cure and Surface Hardness of Resins (opens in a new tab)

  3. Fabrication and characterisation of SWCNT-PMMA and charcoal-PMMA composites with superior electrical conductivity and surface hardness properties

    … which showed a 400 % improvement in Vickers microhardness – raising the polymer matrix abrasion property literally to that of Aluminium alloys (Dobrazanski et al 2006). In conclusion, it is to be noted that Activated Charcoal - PMMA composites have a great potential for cost effective conducting …

    unsw Repository record for Fabrication and characterisation of SWCNT-PMMA and charcoal-PMMA composites with superior electrical conductivity and surface hardness properties (opens in a new tab)

  4. A comparison of fluoride uptake, enamel surface hardness and surface remineralization using three different fluoride varnishes: in vitro study

    … to Coca Cola for 20 mins demineralization (DM). Surface micro-hardness of each tooth was measured at three random locations using Knoop hardness and fluoride content of each tooth was analyzed under (SEM/EDS) at baseline, after each fluoride varnish application, and demineralization treatment. …

    bu Repository record for A comparison of fluoride uptake, enamel surface hardness and surface remineralization using three different fluoride varnishes: in vitro study (opens in a new tab)

  5. Evaluation of Effect of 17% EDTA and 5.25% Sodium Hypochloride Irrigating Solutions on Surface Hardness of Brasseler Endosequence Root Repair Material

    … sodium hypochlorite irrigating solutions on surface hardness of Endosequence Root Repair Material Putty (ERRM). Method: ERRM, 5.25% Sodium Hypochlorite, 17% EDTA and Deionized water were used. 42 samples were prepared and divided into 2 groups. Each group was divided in three sub groups. Sub …

    marquette Repository record for Evaluation of Effect of 17% EDTA and 5.25% Sodium Hypochloride Irrigating Solutions on Surface Hardness of Brasseler Endosequence Root Repair Material (opens in a new tab)

  6. Plieno bandinių paviršiaus kietumo tyrimai naudojant femtosekundiniu lazeriu indukuotos plazmos spektroskopijos metodą /

    … One of LIBS many applications includes the surface hardness measurements of metals. Proving to be a modern alternative to abrasive traditional tests of surface hardness, LIBS is an easy, efficient and user-friendly way to evaluate the surface hardness of solid targets. The purpose of this …

    vilnius Repository record for Plieno bandinių paviršiaus kietumo tyrimai naudojant femtosekundiniu lazeriu indukuotos plazmos spektroskopijos metodą / (opens in a new tab)

  7. Plieno bandinių paviršiaus kietumo tyrimų naudojant UV ir IR femtosekundiniu lazeriu indukuotos plazmos spektroskopijos metodą palyginimas /

    Materials surface hardness measurements in the industry are mainly done by means of deformation (Vickers, Brinell etc.) and result in visible craters as well as require special material preparation, as specific specimen form requirements have to be met. Because of these limitations, applied method …

    vilnius Repository record for Plieno bandinių paviršiaus kietumo tyrimų naudojant UV ir IR femtosekundiniu lazeriu indukuotos plazmos spektroskopijos metodą palyginimas / (opens in a new tab)

  8. Surface properties and the bioactivity of glass-ionomer dental cements and related materials

    The improvement and modification of the surface hardness of glass-ionomer dental cements was investigated in the studies discussed in this thesis to allow the range of clinical applications of these cements to be extended. Storing the cements in non-aqueous media whilst heating at 60 oC increased …

    greenwich

  9. COMPARING THE MECHANICAL PROPERTIES OF CONVENTIONAL, MILLED, AND 3D-PRINTED OCCLUSAL SPLINT MATERIALS: AN IN VITRO STUDY

    … Flexural strength, flexural modulus and surface hardness were measured. The three-point flexure test was used for the determination of flexural strength and modulus values, while Vickers hardness and Shore D hardness were measured to determine surface hardness. Twenty specimens (n = 20) …

    marquette Repository record for COMPARING THE MECHANICAL PROPERTIES OF CONVENTIONAL, MILLED, AND 3D-PRINTED OCCLUSAL SPLINT MATERIALS: AN IN VITRO STUDY (opens in a new tab)

  10. The Presence, Implications, and Mitigation of Within-Field Variability on Sports Fields

    … The first explored short-term variability of surface hardness, soil moisture, turfgrass cover, and normalized difference vegetation index of a soccer pitch during a nine-day professional soccer tournament in a stadium environment. Surface hardness and soil moisture changed the least, while …

    tamu Repository record for The Presence, Implications, and Mitigation of Within-Field Variability on Sports Fields (opens in a new tab)

  11. Empirical correlations between rock cutting parameters and excavated rock surface rebound hardness

    … field excavation, cutting tools operate on rock surfaces damaged from previous tool pass, yet, average intact rock properties are often used in field project estimations. This can result in overestimation of excavation time and cost. The ability to accurately correlate the damaged rock properties …

    must-thes Repository record for Empirical correlations between rock cutting parameters and excavated rock surface rebound hardness (opens in a new tab)

  12. Comparison of shockwave aerification and conventional aerification methods on athletic fields

    <p>Providing a safe and attractive playing surface should be the goal of every athletic field manager. Athletic field use is growing faster than budgets that maintain them. With the added use, there is extra demand on the playing surface, including wear and soil compaction. Developing turfgrass …

    iastate Repository record for Comparison of shockwave aerification and conventional aerification methods on athletic fields (opens in a new tab)

  13. Evaluation of Crumb Rubber Dynamics for Improving Athletic Field Quality

    … rubber (CR) is an amendment used to reduce surface hardness and increase wear-tolerance on athletic fields. Turf managers can topdress CR particles into highly trafficked portions of athletic fields; however, optimum particle size and topdressing depth combinations for use on bermudagrass …

    ut-knoxville Repository record for Evaluation of Crumb Rubber Dynamics for Improving Athletic Field Quality (opens in a new tab)

  14. Using Organic Amendments to Stabilize Sand-based Athletic Fields During Turfgrass Establishment Period

    … fiber, StaLok, in the top 10 cm of the rootzone. Surface hardness, volumetric water content, traction, penetration resistance and visual quality were measured 2 to 4 months after construction of the plots. Surface hardness was greatest in the inorganic stabilizer and the wheat straw treatments. …

    ndsu Repository record for Using Organic Amendments to Stabilize Sand-based Athletic Fields During Turfgrass Establishment Period (opens in a new tab)

  15. Evaluation of surface mechanical properties of pot hardware materials in continuous galvanizing lines

    … of pot hardware in such conditions can cause surface degradation of the pot hardware materials thereby decreasing their life. The surface degradation can be due to wear, decrease in hardness or change in surface elastic modulus. The 500-lb lab scale test set-up at WVU was used to simulate the …

    wvu Repository record for Evaluation of surface mechanical properties of pot hardware materials in continuous galvanizing lines (opens in a new tab)

  16. Femtosekundiniais lazerio impulsais indukuotos plazmos spektroskopijos taikymas medžiagų mechaninio kietumo matavimams /

    … the most recent uses LIBS has found itself in is surface hardness measurements. Alongside the standard sufrace hardness measurement techniques, such as Vicker’s or Knoop tests, LIBS may find many new potential uses thanks to its unique advantages over the former – mainly the lack of need for the …

    vilnius Repository record for Femtosekundiniais lazerio impulsais indukuotos plazmos spektroskopijos taikymas medžiagų mechaninio kietumo matavimams / (opens in a new tab)

  17. AN IN-VITRO COMPARISON OF THE RETENTION OF PREFABRICATED PARALLEL-SIDED VENTED TITANIUM POSTS CEMENTED WITH THREE DIFFERENT DUAL-POLYMERIZABLE RESIN CEMENTS

    … and to relate diametral tensile stress and hardness as a measure of the degree of polymerization to the retentive strength of the different dual-polymerizable resin cements. Material and methods: 60 human extracted premolar teeth were endodontically-treated and randomly divided into 4 test …

    vcu Repository record for AN IN-VITRO COMPARISON OF THE RETENTION OF PREFABRICATED PARALLEL-SIDED VENTED TITANIUM POSTS CEMENTED WITH THREE DIFFERENT DUAL-POLYMERIZABLE RESIN CEMENTS (opens in a new tab)

Page 1 of 9