Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 18 of 18 for “"surface temperature measurement"”.
-
Surface temperature measurement in thin plastic films
Thesis (M.S.)--Michigan State University. Dept. of Forest Products, 1965
-
Global Surface Temperature Measurement for Hypersonic Flight Vehicles
… thermal paints as a technique for global surface temperature measurements on short-duration hypersonic flight vehicles. The thermal paints provide an inexpensive, robust and relatively quick way of instrumenting hypersonic flight vehicles to measure in-flight surface temperatures through a …
-
A System for Ocular Surface Temperature Measurement Using Infrared Thermography
Background: Ocular surface temperature (OST) is affected by changes in the physiology of the eye caused by normal homeostasis, environmental changes, or systemic and local disease. OST can help a physician to diagnose eye disease with improved accuracy and provide useful information for eye …
-
Development of a six-wavelength optical pyrometer for non-contact surface temperature measurement
… designed, developed and tested for non-contact surface temperature measurement of opaque materials in the temperature range of 500 to 1000 °C. The system included a rotating filter wheel containing six narrow band optical band pass filters and a liquid nitrogen cooled HgCdTe infrared detector. A …
-
Application of liquid crystals to surface temperature measurement on plates heated by cyclic bending
Temperature is a parameter which is important because of its influence on other material properties. Many temperature measurement techniques are available but few of them permit a direct visualization of surface temperature Variation. The Liquid crystal method is one of the rare methods that …
-
Silicon wafer surface temperature measurement using light-pipe radiation thermometers in rapid thermal processing systems
… thermometers (LPRTs) are widely used to monitor temperature during thermal processes, particularly semiconductor wafer Rapid Thermal Processing (RTP). According to the International Technology Roadmap for Semiconductors 2004 (ITRS), temperatures for semiconductor wafer processing should be …
-
Factors affecting the precision and accuracy of surface temperature measurement using light-pipe radiation thermometers (LPRTs)
The accurate measurement of temperature in Rapid Thermal Processing (RTP), a key technique that processes single silicon wafers at a lower cost and in a shorter period of time, is of vital importance for improving the productivity of high quality devices. In order to meet the requirement of the …
-
Dynamic surface temperature measurement on the first stage turbine blades in a turbofan jet engine test rig
Turbine blade surface temperatures were studied during transient operation in a turbofan engine test rig. A single fiber radiation pyrometer was used to view the suction side of the blades from approximately 60 percent axial chord to the trailing edge at an average radial location of 70 percent …
-
Impedance-based battery temperature monitoring
<p>Accurate on-board temperature monitoring of lithium-ion batteries is important for safety and control purposes. Impedance temperature detection (ITD) is a promising approach for temperature estimation, whereby the internal cell temperature is directly inferred from online electrochemical …
-
Vaikų hemangiomų prognozės ir gydymo veiksmingumo vertinimas infraraudonųjų spindulių termografija /
… were: 1) To determine the diagnostic value of surface temperature measurement of infantile hemangiomas (IH) using infrared thermography; 2) To determine and analyze the peak and average surface temperature values of IHs using infrared thermography; 3) To identify proliferation risk factors of …
-
Evaluation of treatment effectiveness and prognosis of infantile hemangioma by infrared thermography. Summary /
… were: 1) To determine the diagnostic value of surface temperature measurement of infantile hemangiomas (IH) using infrared thermography; 2) To determine and analyze the peak and average surface temperature values of IHs using infrared thermography; 3) To identify proliferation risk factors of …
-
Catalytic converter thermal model for hybrid electric vehicle engine on/off control strategy development
… to the surroundings due to the incorrect shell surface area to volume ratio. Therefore, an adiabatic assumption was used to analyze the substrate’s thermal behavior without the influence of external heat transfer. The analytical model was experimentally validated with an engine that provided …
-
In-Situ Surface Deformation and IR Emission Measurements for Solid Oxide Fuel Cells
… anodes are also subjected to stresses at high temperature, thermal/redox cycles effects during long-term operation. In order to identify such degradation mechanisms and to determine the effects of those mechanisms on the long-term operation of SOFCs, a powerful in-situ test technique that can …
-
Experimental Flow Visualization and Temperature Measurements for Validation in Hemispherical Upper Plenum and Pebble Bed Geometries
… hemispherical plenum features heavily in high temperature gas cooled reactors (HTGRs) as well as liquid metal reactor systems. In a loss of flow (LOF) accident scenario in a HTGR, flow direction is reversed and is driven by natural convection upward from the core. Liquid metal reactor vessels …
-
Development of Local Transient Heat Flux Measurements in an Axisymmetric Hybrid Rocket Nozzle
A method of performing local transient heat flux measurements in an uncooled axisymmetric hybrid rocket nozzle is presented. Surface temperatures are collected at various axial locations during short duration tests and post processed using finite difference techniques to determine local transient …
-
Study Of Periodical Flow Heat Transfer In An Internal Combustion Engine
… efficiency for IC engine. In-cylinder wall temperature has to be precisely controlled to achieve high efficiency and low emission. However, this cannot be done without knowing gas-to-wall heat flux. This study reports on the development of a technique suitable for engine in-cylinder surface …
-
Development and implementation of a workflow for measurement of surface temperature by means of infrared thermography and Thermodynamic and economic analysis of the incorporation of the supercritical carbon dioxide Brayton cycle into combined cycle power plants
In part one a workflow for the measurement of surface temperature by means of infrared thermography using a semi empirical equation based on Planck's law of radiation is designed and implemented in Matlab. Procedures for acquiring scaled irradiance from camera detector signal using pixelwise …
-
Responsive temperature and pressure sensor design for in-situ prosthesis monitoring applications based on the piezoelectric and pyroelectric effects in lead zirconate titanate
… effects that can be used to measure both temperature and/or axial stress for specific use within a prosthetic socket, and more generally as a responsive temperature sensor capable of detecting high frequency skin temperature oscillations in medical diagnostic applications. Knowledge of an …