Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 20 for “"suture anchors"”.

  1. Standardization of test methodology: a comparison between three suture anchors

    Suture anchors have been used successfully in many applications in orthopedics. They have been in the forefront of research in the recent years. Most of the studies, though, have focused on human suture anchors. This research concentrates on the veterinary aspect of suture anchors. Currently, there …

    tamu Repository record for Standardization of test methodology: a comparison between three suture anchors (opens in a new tab)

  2. BIOMECHANICAL ANALYSIS OF POLYESTER SILICONE-COATED ARTIFICIAL TENDON AND ACCOMPANYING SUTURE ANCHORS

    … tendon is replaced with an artificial tendon, suture anchors are one option for attaching the artificial tendon to bone. The mechanical characteristics of the suture anchor used in musculoskeletal reconstructions (e.g. to attach an artificial tendon) can limit the strength of the attachment and …

    utk-theses Repository record for BIOMECHANICAL ANALYSIS OF POLYESTER SILICONE-COATED ARTIFICIAL TENDON AND ACCOMPANYING SUTURE ANCHORS (opens in a new tab)

  3. Optimization of Insertion Holes and Anchor Design for Cylinder Shaped Toggle Type Suture Anchors

    … anchor design for cylinder shaped toggle type suture anchors. Four types of anchors were investigated in terms of pull strength and design in acrylic plate and pig bone. They included small type A and B anchors and large type A and B anchors. Pull strength trends suggest that the small type …

    eiu Repository record for Optimization of Insertion Holes and Anchor Design for Cylinder Shaped Toggle Type Suture Anchors (opens in a new tab)

  4. In vitro evaluation of veterinary and human suture anchors in metaphyseal bone of the canine tibia

    … THE UNIVERSITY OF MISSOURI AT AUTHOR'S REQUEST.] Suture anchors, also called bone or tissue anchors, provide orthopedic surgeons a mechanism for secure fixation of soft tissues to bone. A human system (TwinFix[superscript TM]) has been validated for clinical use by both in vitro and in vivo …

    missouri Repository record for In vitro evaluation of veterinary and human suture anchors in metaphyseal bone of the canine tibia (opens in a new tab)

  5. Frontal Plane Humeral Elevation Effects on the Pullout Strength of Suture Anchors Used in Rotator Cuff Repair

    … method of surgery involves the insertion of a suture anchor into the humeral head that ties the detached tendon using sutures back to bone. Usage of suture anchors promotes healing of the supraspinatus tendon onto the bone re-establishing movement of the arm. Although they provide a suitable …

    calpoly Repository record for Frontal Plane Humeral Elevation Effects on the Pullout Strength of Suture Anchors Used in Rotator Cuff Repair (opens in a new tab)

  6. Εμβιομηχανική της συρραφής και καθήλωσης του μυοτενόντιου πετάλου του ώμου: πειραματική μελέτη σε παρασκευάσματα προβάτου

    … of our work was to assess load to failure of sutures, suturing techniques, and suture anchors used in rotator cuff surgery. Ten types of sutures (absorbable and non-absorbable), four types of suturing techniques and eight types of sutures anchors (bioabsorbale and metallic) commonly used in …

    greece Repository record for Εμβιομηχανική της συρραφής και καθήλωσης του μυοτενόντιου πετάλου του ώμου: πειραματική μελέτη σε παρασκευάσματα προβάτου (opens in a new tab)

  7. Effects of tendon viscoelasticity on the distribution of forces across sutures in a model tendon-to-bone repair

    … These repairs often culminate in re-tearing when sutures break through the tendon in the weeks following repair. Numerous studies have been performed to identify suturing strategies that reduce this risk by balancing forces across sutures. However, the structural engineering basis for these …

    wustl Repository record for Effects of tendon viscoelasticity on the distribution of forces across sutures in a model tendon-to-bone repair (opens in a new tab)

  8. Current approaches to treating chronic ankle instability with lateral ankle ligament repair

    … of orthopedic surgery. The use of arthroscopy, suture anchors, and suture tape augmentation have dramatically changed the approach previously taken to carry out the modified Brostrom repair, but the effects of these new strategies have not been widely studied. This review aims to assess the …

    bu Repository record for Current approaches to treating chronic ankle instability with lateral ankle ligament repair (opens in a new tab)

  9. Cyclic Elongation and Pull Out of Unicortical and Bicortical Suture Anchor Designs

    … AND PULL OUT OF UNICORTICAL AND BICORTICAL SUTURE ANCHOR DESIGNS JUSTIN LESLEY BIOMEDICAL ENGINEERING ABSTRACT A novel suture anchor design was introduced and biomechanically tested. The novel design involved lengthening a standard metal screw type anchor so as to achieve greater fixation in …

    uab Repository record for Cyclic Elongation and Pull Out of Unicortical and Bicortical Suture Anchor Designs (opens in a new tab)

  10. The study of hydroxyapatite reinforced polylactic acid composites for orthopedic applications

    … devices, such as interference screws and suture anchors. However, the critical disadvantages of poor biological properties and poor mechanical strength compared to metal devices have left much to be desired in bioabsorbable orthopedic implant materials. In order to develop a more ideal …

    missouri Repository record for The study of hydroxyapatite reinforced polylactic acid composites for orthopedic applications (opens in a new tab)

  11. Surgical implant and tissue interface

    … dissertation concern stresses applied by the suture to adjacent laryngeal cartilage or collateral ligaments, enthesis restoration using commercially available suture anchors, as well as stability of suture anchor and stainless-steel screw within bone tissue under different loading conditions. …

    utk-theses Repository record for Surgical implant and tissue interface (opens in a new tab)

  12. Design and Verification of Shape Memory Polymer Embolization Devices for Peripheral Indications

    … medical industry in the form of self-tightening sutures, suture anchors, ligament fixation devices, vascular stents, and thrombectomy devices. New formulations of polyurethane SMP scaffolds are gaining significant interest for use in vascular embolization procedures. These scaffolds have …

    tamu Repository record for Design and Verification of Shape Memory Polymer Embolization Devices for Peripheral Indications (opens in a new tab)

  13. OXYGEN DELIVERY BY OUTGASSING OF HYPERBARICALLY LOADED MICROTANKS AND BULK POLYMERS FOR BIOMEDICAL APPLICATIONS

    … clinically used polymer implants such as screws, suture anchors, stiches, etc. as elevated local oxygen tensions have been shown to enhance collagen deposition and reduce infection. Indeed, the biomedical applications are diverse and abundant.

    jhu Repository record for OXYGEN DELIVERY BY OUTGASSING OF HYPERBARICALLY LOADED MICROTANKS AND BULK POLYMERS FOR BIOMEDICAL APPLICATIONS (opens in a new tab)

  14. Morphological and mechanical analysis of the glenoid trabecular bone

    … and to investigate the strength of the bone anchors as a function of bone density. Nineteen embalmed and six fresh frozen human glenoids were acquired for testing. In order to determine basic morphological and mechanical properties, specimens were tested using a flat cylindrical indentor at …

    whiterose Repository record for Morphological and mechanical analysis of the glenoid trabecular bone (opens in a new tab)

  15. BIOMIMETIC APPROACHES FOR ROTATOR CUFF REPAIR AND REGENERATION

    … (BMS) engineered to integrate with conventional suture anchors, delivering spatially organized structural and biological cues to drive functional enthesis regeneration. First, we established a biomimetic structural framework designed to mimic the native stiffness and alignment gradients of the …

    penn Repository record for BIOMIMETIC APPROACHES FOR ROTATOR CUFF REPAIR AND REGENERATION (opens in a new tab) Embargoed until 2029-06-05

  16. Anwendungssicherheit, Biokompatibilität und Temperaturanalyse der BoneWelding® Technologie in der Halswirbelsäule - eine in vivo Studie am Schaf

    … plating system, two converging polymer pins and suture anchors to the cervical vertebral bodies. Polymer screws were used as controls. The observation period of the six sheep was two months. According to the ISO norm 10933-6 the samples were evaluated by macroscopical, radiographical and …

    zurich Repository record for Anwendungssicherheit, Biokompatibilität und Temperaturanalyse der BoneWelding® Technologie in der Halswirbelsäule - eine in vivo Studie am Schaf (opens in a new tab)

  17. Comparison of Sutures and Devices Used in Closure Following Partial Nephrectomy Suturing

    … During the first experiment, a standard suture anchor Hem-o-lok device, a standard stop knot, and three prototype devices were compared to each other based on the amount of tension that could be placed on a suture before there was a tear in renal tissue. The renal remnant of a …

    gvsu Repository record for Comparison of Sutures and Devices Used in Closure Following Partial Nephrectomy Suturing (opens in a new tab)

  18. Klinisches und radiologisches Outcome nach arthroskopischer anteroinferiorer Schulterstabilisierung

    Zusammenfassung Die Operationstechnik der arthroskopischen Schulterstabilisierung und die dabei verwendeten Implantate befinden sich in einer stetigen Weiterentwicklung. Die Verwendung von Fadenankern hat sich hierbei seit Jahren bewährt. Auch die Verwendung knotenfreier Anker führte bislang zu …

    fu-berlin Repository record for Klinisches und radiologisches Outcome nach arthroskopischer anteroinferiorer Schulterstabilisierung (opens in a new tab)

  19. Klinische und kernspintomographische Aspekte nach Rotatorenmanschettenrekonstruktion in Doppelreihentechnik

    … wurden arthroskopisch entweder in modifizierter SutureBridge- oder in knotenfreier SpeedBridge- Technik operiert. Bei den verwendeten Ankermaterialien handelte es sich um bioresorbierbare poly-L-lactic acid (PLLA) oder nicht resorbierbare polyetheretherketon (PEEK) Fadenanker. Zu definierten …

    fu-berlin Repository record for Klinische und kernspintomographische Aspekte nach Rotatorenmanschettenrekonstruktion in Doppelreihentechnik (opens in a new tab)

  20. Klinische und funktionelle Ergebnisse nach Refixation der distalen Bizepssehne mit All-Suture Ankern

    … und Fixationsmethoden verwendet werden. All-Suture Anker gewinnen als Fixationsmethode bei Rupturen der distalen Bizepssehne zunehmend an Bedeutung, jedoch fehlen umfassende klinische Daten zu ihrer Anwendung. Methodik Diese retrospektive Kohortenstudie analysiert die funktionellen und …

    fu-berlin Repository record for Klinische und funktionelle Ergebnisse nach Refixation der distalen Bizepssehne mit All-Suture Ankern (opens in a new tab)