Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 42 for “"synchrotron light source"”.

  1. X -Ray and Pressure Measurements on Helium Solids

    … data obtained from experiments at the National Synchrotron Light Source at the Brookhaven National Laboratory are also presented here. The vacancy formation energy of fcc 4He at 10.4 cm3 /mol was obtained by two different methods. In addition, c/a ratios were determined to be ideal for hcp 4He …

    uiuc Repository record for X -Ray and Pressure Measurements on Helium Solids (opens in a new tab)

  2. Studies of a group III nitrides thin film growth

    … during AlN and InN thin film growth. We used synchrotron-based real-time grazing-incidence small-angle X-ray scattering (GISAXS), in order to study the plasma-assisted atomic layer epitaxy (ALEp) process. The substrate for deposition was single-crystal GaN. We designed the load lock and other …

    bu Repository record for Studies of a group III nitrides thin film growth (opens in a new tab)

  3. Mechanical support design of analyzer for a diffraction enhanced x-ray imaging (DEI) system

    Diffraction Enhanced X-ray Imaging (DEI) uses synchrotron X-ray beams prepared and analyzed by perfect single crystals to achieve imaging contrast from a number of phenomena taking place in an object under investigation. The crystals used in DEI for imaging requires high precision positioning due …

    sask Repository record for Mechanical support design of analyzer for a diffraction enhanced x-ray imaging (DEI) system (opens in a new tab)

  4. Electron beam sizes and lifetimes at MAX II and MAX III

    The MAX II and MAX III synchrotron light sources at MAX-lab provide synchrotron radiation for experiments in a wide variety of research fields. The synchrotron radiation is emitted by ultra-relativistic electrons circulating in electron storage rings. In this thesis the transverse and longitudinal …

    lund Repository record for Electron beam sizes and lifetimes at MAX II and MAX III (opens in a new tab) Download PDF for Electron beam sizes and lifetimes at MAX II and MAX III (opens in a new tab)

  5. Vibrational spectroscopic study of the 1,3,5,7-cyclooctatetraene at high static pressures

    … of pressure were collected at the National Synchrotron Light Source (NSLS) U2A beamline, as well as its Raman spectra over pressure using a micro-Raman spectrometer. The spectra show the typical stiffening of force constants with increasing pressure for most peaks, particularly those which …

    unlv Repository record for Vibrational spectroscopic study of the 1,3,5,7-cyclooctatetraene at high static pressures (opens in a new tab) Download PDF for Vibrational spectroscopic study of the 1,3,5,7-cyclooctatetraene at high static pressures (opens in a new tab)

  6. Synchrotron infrared spectroscopy of domain walls and high pressure phases of multiferroics

    <p>Synchrotron light sources provide high throughput, broadband infrared light enabling the development of novel techniques, inaccessible using traditional sources. High pressure techniques benefit greatly, as significant signal loss occurs from focusing the light through diamonds into a small …

    utk-theses Repository record for Synchrotron infrared spectroscopy of domain walls and high pressure phases of multiferroics (opens in a new tab)

  7. In situ synchrotron radiation computed laminography for materials failure analysis

    … the development of computed laminography using synchrotron radiation (SRCL), and its applications dedicated to in operando materials science. During this work, an in situ computed laminography implementation has been <br>installed at the TopoTomo beamline (<30 keV) at the ANKA synchrotron light …

    freiburg-diss Repository record for In situ synchrotron radiation computed laminography for materials failure analysis (opens in a new tab)

  8. Otimização de um protocolo de fixação e marcação para estudo do Rhodnius prolixus usando microtomografia síncrotron

    During the years microtomography using synchrotron light technique has proved to be an excellent tool to study the internal and external structures of Rhodnius prolixus, main insect vector of Tripanossoma cruzi, and the etiologic agent of Chagas Disease. However, the first works have shown that the …

    brazil-uerj Repository record for Otimização de um protocolo de fixação e marcação para estudo do Rhodnius prolixus usando microtomografia síncrotron (opens in a new tab)

  9. Static high pressure FT-IR spectroscopic studies of TATB

    … (e.g. small sample sizes and apertures), synchrotron radiation sources are ideal for probing the structure of materials at the molecular level. 1,3,5-triamino-2,4,6-trinitrobenzene (TATB) is an insensitive (tertiary) high explosive (iHE) useful in military applications. Compared to other …

    unlv Repository record for Static high pressure FT-IR spectroscopic studies of TATB (opens in a new tab) Download PDF for Static high pressure FT-IR spectroscopic studies of TATB (opens in a new tab)

  10. Considerations in the design and operation of synchrotron radiation beamlines (including a discussion on the properties of synchrotron radiation

    The X-ray optics of synchrotron radiation beamlines are considered in this paper. The characteristics of synchrotron radiation which make it the premier source of light for studies in many regions of the electromagnetic spectrum are given. A chapter is devoted to the collimating, focusing and …

    vt Repository record for Considerations in the design and operation of synchrotron radiation beamlines (including a discussion on the properties of synchrotron radiation (opens in a new tab)

  11. Energy Recovery Linear Accelerator Lattice Design and Coherent Synchrotron Radiation

    … potential drivers for novel fourth-generation synchrotron light sources. An ERL combines the high quality beams of a linear accelerator with the high currents possible in a storage ring. The excessive power needs of a lone linac are avoided by circulating accelerated particles back through the …

    cornell Repository record for Energy Recovery Linear Accelerator Lattice Design and Coherent Synchrotron Radiation (opens in a new tab)

  12. Opto-mechanical design of synchrotron radiation-based far-infrared spectroscopic ellipsometer with strong magnetic-field

    … is to present opto-mechanical design of a synchrotron radiation based far-infrared spectroscopic ellipsometer with a strong external magnetic-field capability. Since high magnetic field has enabled major breakthrough in science such instrument will be highly important to the field of …

    njit Repository record for Opto-mechanical design of synchrotron radiation-based far-infrared spectroscopic ellipsometer with strong magnetic-field (opens in a new tab)

  13. X-ray absorption study of the interaction of coal combustion gases with calcium oxide.

    … on coal samples at beamline X18B at the National Synchrotron Light Source. The coal samples were probed at both the calcium and sulfur environments. Also in-situ measurements were made on the coal sample to study the evolution of sulfur on heating. The reaction of sulfur dioxide, evolved from the …

    wvu Repository record for X-ray absorption study of the interaction of coal combustion gases with calcium oxide. (opens in a new tab)

  14. Exploration of novel ferroelectric systems: determination of the underlying mechanisms

    … and magnetic fields) are studied using synchrotron X-ray diffraction (XRD), Raman spectroscopy, X-ray pair distribution function (PDF), X-ray absorption fine structure (XAFS), X-ray absorption near-edge structure (XANES) measurements and DFT modeling. The work combines research at NJIT, …

    njit Repository record for Exploration of novel ferroelectric systems: determination of the underlying mechanisms (opens in a new tab)

  15. In-Vivo X-Ray Fluorescence Assessment of Iron Levels in the Skin for β-Thalassemia Patients

    … sites of 6 cadavers were investigated in a synchrotron light source facility. Maps of iron, zinc and calcium distribution as a function of skin depth were then constructed. It was found that all three elements were significantly present in the epidermal layer compared to the dermal one. …

    mcmaster Repository record for In-Vivo X-Ray Fluorescence Assessment of Iron Levels in the Skin for β-Thalassemia Patients (opens in a new tab)

  16. Porphyrin-DNA as scaffold for nanoarchitecture and nanotechnology

    … be monitored. Using CD spectroscopy based on a synchrotron light source, the first measurements were made of DNA in the far UV region (< 200 nm). All the results obtained in this work and elsewhere during the past few years show that DNA based materials are highly promising for future …

    soton Download PDF for Porphyrin-DNA as scaffold for nanoarchitecture and nanotechnology (opens in a new tab)

  17. RAS and STM investigations of pentacene molecules on metal and semiconductor surfaces

    … level and valence band photoemission using a synchrotron light source. Deposition o f pentacene on the Ag/Si(l 11)-(V3 xy/3 ) surface produced three distinct ordered structures for coverages up to one monolayer. It is concluded from the RAS, STM, synchrotron studies that the molecule lies flat …

    dcu Download PDF for RAS and STM investigations of pentacene molecules on metal and semiconductor surfaces (opens in a new tab)

  18. Integration of Ferroelectric HfO2 onto a III-V Nanowire Platform

    … materials using both electrical and operando synchrotron light source techniques. After optimizing both the films and the top electrode, the gate stack is integrated onto vertical InAs nanowires on Si in order to successfully implement FeFETs. Their performance and reliability can be explained …

    lund Repository record for Integration of Ferroelectric HfO2 onto a III-V Nanowire Platform (opens in a new tab) Download PDF for Integration of Ferroelectric HfO2 onto a III-V Nanowire Platform (opens in a new tab)

Page 1 of 3