Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 32 for “"synchrotron radiation source"”
-
The spectroscopic study of simple polyatomic molecules by synchrotron and laser irradiation
… molecules, for example NO and Cl2O by UV radiation derived from synchrotron and laser sources. Synchrotron studies were carried out at the Daresbury Laboratory Synchrotron Radiation Source, and the laser studies performed at University College London. The thesis is composed of six …
-
Structural insights into pharmaceutical solids from synchrotron and laboratory x-ray powder diffraction data
… data collected in the laboratory or at a synchrotron radiation source, the crystal structures of pharmaceutically relevant materials were solved successfully and reproducibly. The crystal structures which were solved are moderately complex, and at the midpoint of the complexity that can be …
-
X-ray crystallographic studies of glycogen phosphorylase b
… been collected on an oscillation camera, using a synchrotron radiation source and cylindrical film cassettes. An intensity gain of up to 13O times, compared to a GX6 rotating anode source, was obtained with the synchrotron radiation source. A reduction in radiation damage, was also observed. The …
-
Development of diffraction enhanced computed tomography for imaging joints
… combined with computed tomography (CT) using a synchrotron radiation source. DEI is a modality that derives contrast from x-ray refraction, extinction (an extreme form of scatter rejection), and absorption (as in conventional radiography). The ability to add to an image’s contrast from the …
-
Compton Polarimetry of 6 - 35 keV X-rays: Influence of Breit Interaction on the Linear Polarisation of KLL Dielectronic Recombination Transitions in Highly Charged Ions
… been developed for polarisation measurements at synchrotrons. It has been developed for X-ray polarimetry with a high energy resolution for energies between 6 keV and 35 keV. It was tested in the course of polarisation measurements at an electron beam ion trap and at a synchrotron radiation …
-
Investigation of sulphur based passivation treatments of III-IV semiconductor surfaces
… Surfaces have been investigated at Daresbury Synchrotron Radiation Source in Ultra High Vacuum (UHV) conditions before and after molecular sulphur adsorption. The surface geometry has been determined using Low Energy Electron Diffraction (LEED). The surface composition and electronic structure …
-
Front end x-ray beam position monitors at the Canadian Light Source
… Monitors (XBPM) used on the Canadian Light Source front ends is described in this thesis, from the design concepts to the practical implementation and commissioning. Surveyed into position to provide a fiducialized point of origin for incoming synchrotron radiation, the primary purpose of …
-
Development of microplasmas and analysis of complex biomolecules using plasma and synchrotron radiation
In this work, a microplasma-based ionization source for ambient mass spectrometry (AMS) has been developed. Optical emission spectroscopy, optical microscopy, and electrical measurements have been used to characterize the discharge. The discharge was used in a direct exposure mode in AMS …
-
Novel nonresonant and resonant mechanisms leading to the breakdown of the Franck-Condon approximation in photoionization
… photoelectron spectroscopy, and undulator-based synchrotron radiation at the Advanced Light Source, a synchrotron radiation source in Berkeley, California. Data are collected from near threshold to several hundred electron volts (eV) above the ionization potential. The approach is to examine how …
-
Purification, characterization, crystallization and preliminary x-ray structure determination of scytalidium thermophilum bifunctional catalase and identification of its catechol oxidase activity
… diffraction data was collected at the Daresbury Synchrotron Radiation Source (United Kingdom) at 2.7 Å resolution. The preliminary structure was solved by molecular replacement method using Penicilium vitale catalase structure. CCO was verified to have a tetrameric structure with two homodimers …
-
Double photoionization of alkaline earth atoms and photoelectron spectroscopy of reactive intermediates
… process has been studied using monochromatic radiation produced by the second generation Daresbury synchrotron radiation source (SRS). The extremely low cross sections of the DPI processes were enhanced by using incident radiation at wavelengths corresponding to autoionizing resonances of the …
-
Structural properties of solid ionic halides.
… by High Resolution X-ray Diffraction using the synchrotron radiation source at the Daresbury Laboratory. This work provides a basis for the further systematic investigation of these systems.
-
Development of a technique for 3D grain reconstruction of fine grained structures via nano diffraction
… developed for the beamline P03 at the PETRA III synchrotron radiation source to enable a high-precision and spatially resolved characterization of micro- and nanostructures in materials. The focus of the work is on the detailed development of the experimental setup, which allows the acquisition …
-
Structural characterisation of semi-insulating LEC gallium arsenide
Double crystal x-ray topography using a synchrotron radiation source has been used to measure the lattice distortions present in 50mm diameter samples of (001) semi-insulating LEG gallium arsenide. Lattice strains and tilts have been mapped in In-doped and undoped samples as well as annealed and …
-
Gas phase vacuum-ultraviolet (vuv) spectroscopy of small halogenated polyatomic molecules
… in the gas phase with vacuum-ultraviolet (VUV) radiation. For all the experiments described in this thesis, the source of radiation was from tuneable VUV radiation from a synchrotron source. The majority of the experiments used the UK national source located at Daresbury Cheshire. Fluorescence …
-
New science exploration from XFEL: a new paradigm for structural visualisation of macromolecules
… has been a major benefactor of advances in x-ray radiation sources. Currently two major bottlenecks exist within this field, the need for well diffracting crystals and radiation damage limitations. The advent of fourth generation x-ray sources, X-ray Free-electron Lasers (XFEL) heralds a shift in …
-
Electronic structure of quasicrystals studied by photoemission spectroscopy.
… measurements have been carried out using synchrotron radiation source in the photo-energy range 35-150 eV. The studied quasicrystals are icosahedral Al$\rm\sb{70}Pd\sb{20}Mn\sb ,\ Al\sb{65}Cu\sb{20}Os\sb ,$ and $\rm Al\sb{65}Cu\sb{20}Ru\sb ,$ and decagonal $\rm Al\sb{65}Co\sb Cu\sb{20}$ …
-
Influência dos promotores em catalisadores Ni-X/Al2O3 (X = Mn, Mg, P e Ce) aplicados na reforma a seco do metano
… in addition to hydrogen be considered a source of clean and highly efficient energy, giving it high commercial value. Nickel-based catalysts based on alumina were prepared containing the Mg, Mn, Ce and P promoters, chosen due to their different chemical properties. The synthesis method …
-
Characterisation of imperfections in single crystals of high purity synthetic quartz
… studied using double crystal topography at the Synchrotron Radiation Source, (SRS), at the Daresbury Laboratory. Metal ion impurities were shown to incorporate interstitially into quartz crystals. The only exceptions were aluminium and iron, which incorporated substitutionally. All the …
Page 1 of 2