Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 43 for “"syringe pumps"”

  1. Semiotics & Syringe Pumps

    Semiotics can be a useful paradigm in HCI research and yet the cognitive process of semiosis is difficult to uncover and empirically study. Thus in the domain of HCI semiotics has largely remained a descriptive theory, able to provide a theoretical basis for the study of interfaces and interaction, …

    whiterose Repository record for Semiotics & Syringe Pumps (opens in a new tab)

  2. A Capillary-Based Microfluidic System for Immunoaffinity Separations in Biological Matrices

    … device was assembled from two micro syringe pumps, a microchip mixer, a micro-injector, a diode laser with fused-silica capillary flow cell, and a separation capillary column. The columns were prepared from polymer tubing and packed under negative pressure with a stationary phase that …

    vcu Repository record for A Capillary-Based Microfluidic System for Immunoaffinity Separations in Biological Matrices (opens in a new tab)

  3. Development of a Programmable, Open-Source, and Cost-Effective Fluidic System for Cell Culture Applications

    … fluidic system comprised of three custom-built syringe pumps for cell culture applications. The fluidic system was directly integrated with a multiwell plate on an environmentally controlled microscope platform for live-cell imaging and time-lapse analyses of cellular responses as culture …

    unm Repository record for Development of a Programmable, Open-Source, and Cost-Effective Fluidic System for Cell Culture Applications (opens in a new tab)

  4. Design, Fabrication, and Implementation of a Single-Cell Capture Chamber for a Microfluidic Impedance Sensor

    … the chamber. The device will be designed to use syringe pumps and the syringe-controlled channel will also be used to capture and release the cell to ensure cell control and device reusability. We hypothesize that these characteristics along with other proposed design factors will result in a …

    calpoly Repository record for Design, Fabrication, and Implementation of a Single-Cell Capture Chamber for a Microfluidic Impedance Sensor (opens in a new tab)

  5. Alginate fiber production using co-flow at a milli-fluidic t-junction

    … production of alginate fibers that utilizes just syringe pumps, plastic tubing and a tee tube fitting. Alginate fibres of controlled diameter are produced by adjusting the flowrates of sodium alginate and calcium chloride solutions entering a tee tube fitting. As the two solutions flow through the …

    ttu Repository record for Alginate fiber production using co-flow at a milli-fluidic t-junction (opens in a new tab)

  6. Combining Thermo-plasmonics with Microfluidics for Biological Applications

    … flow patterns were determined using high-quality syringe pumps. An experiment with the simultaneous flow of two colored solutions through the same microfluidic chip demonstrated controlled laminar flow with minimal mixing. Next, thermo-plasmonic experiments were conducted in optimized …

    usf Repository record for Combining Thermo-plasmonics with Microfluidics for Biological Applications (opens in a new tab)

  7. Photoluminescent Nanomaterials for Biosensing and Single Cell Analysis Applications

    … T-junctions to bypass the need for multiple syringe pumps. The relation between the droplet size and the oil-to-water flow ratio (F) was assessed in both gravity-driven flow and syringe pumps, where the droplets' size was inversely proportional to F. The fully characterized multi-input …

    lsu-thes Repository record for Photoluminescent Nanomaterials for Biosensing and Single Cell Analysis Applications (opens in a new tab)

  8. Microfluidics with fluid walls

    … common biology laboratories: a 3-axis traverse, syringe pumps, petri dishes, cell media and FC40. </p>

    oxford Repository record for Microfluidics with fluid walls (opens in a new tab)

  9. Ανάπτυξη αυτόματων μεθόδων προσδιορισμού τοξικών μετάλλων με on-line τεχνικές προκατεργασίας σε συνδυασμό με φασματομετρία ατομικής εκπομπής και απορρόφησης

    … atomic emission spectrometry. Next, a novel dual-syringe flow injection (DSFI) on-line column preconcentration system coupled to flame atomic absorption spectrometry (FAAS) has been developed for automatic trace metal determination in natural waters and biological samples. The proposed layout …

    greece Repository record for Ανάπτυξη αυτόματων μεθόδων προσδιορισμού τοξικών μετάλλων με on-line τεχνικές προκατεργασίας σε συνδυασμό με φασματομετρία ατομικής εκπομπής και απορρόφησης (opens in a new tab)

  10. Measurement of thermodynamic data at elevated pressure and temperature conditions with a microfluidic setup

    … which is furthermore connected to high pressure syringe pumps. Pure compounds and mixtures were studied with the microfluidic setup and different thermodynamic properties were determined. For instance, vapor pressures of Poly(oxymethylene) Dimethyl Ethers (OME3 and OME4), a potential class of …

    qucosa-diss Repository record for Measurement of thermodynamic data at elevated pressure and temperature conditions with a microfluidic setup (opens in a new tab)

  11. Droplets generation and sampling on demand with peristaltic pumping systems

    … generated in a T-junction or flow-focusing with syringe pumps or other pressure sources. An alternative way to generate droplets is to sequentially aspirate aqueous samples and carrier oil under negative pressures. Both of the typical T-junction methods and the current aspiration methods, have …

    soton Repository record for Droplets generation and sampling on demand with peristaltic pumping systems (opens in a new tab)

  12. Development and optimisation of colourimetric microfluidic sensors for water quality monitoring

    … sensor employed a microfluidic chip coupled with syringe pumps for fluid manipulation. It incorporated its own power supply and was programmed to take periodic unassisted measurements, with on-board data storage. Important considerations for sensor design included the sensitivity and selectivity …

    dcu Repository record for Development and optimisation of colourimetric microfluidic sensors for water quality monitoring (opens in a new tab)

  13. Optimization of a Dynamic Hot Water Pretreatment of Switchgrass using Catalysis by Carbonation to Maximize Carbochemical Yields

    … flow apparatus using three high precision Isco syringe pumps and a constant temperature oven to allow carbonation of the water over a range of temperatures and pressure to reactively pretreat switchgrass. Carbochemicals (furan-based aldehydes) and acids that were formed were detected using a …

    arkansas Repository record for Optimization of a Dynamic Hot Water Pretreatment of Switchgrass using Catalysis by Carbonation to Maximize Carbochemical Yields (opens in a new tab)

  14. Development of Integrated Dielectric Elastomer Actuators (IDEAS): trending towards smarter and smaller soft microfluidic systems

    … is often tethered to the laboratory via multiple syringe pumps, vacuum pumps, solenoid valves, gas cylinders and high voltage power supplies. In this dissertation, a procedure for the facile integration of dielectric elastomer (DE) actuators (called IDEAs) onto microfluidic devices is described. …

    ksu Repository record for Development of Integrated Dielectric Elastomer Actuators (IDEAS): trending towards smarter and smaller soft microfluidic systems (opens in a new tab)

  15. Development of front-end pre-analytical modules for integrated blood plasma separation

    … the influence of flow fluctuation in syringe pumps, which are commonly employed in microfluidic setups, on the separation performance of blood plasma separation devices was investigated. These studies not only reveal the reasons behind the slow progress in the development of …

    heriot-watt Repository record for Development of front-end pre-analytical modules for integrated blood plasma separation (opens in a new tab)

  16. Fluid-walled microfluidics for cell migration studies

    … cell culture media, FC40, a 3-axis traverse and syringe pumps. The methods outlined empower biologists to study complex cellular behaviours in environments that more closely mimic in vivo conditions, with the aim of making microfluidic technology accessible to the less experienced user.</p>

    oxford Repository record for Fluid-walled microfluidics for cell migration studies (opens in a new tab)

  17. Laboratory simulation of an enhanced geothermal reservoir

    … while at reservoir conditions. Dual 70 MPa syringe pumps set to flow rates between 10 nL/min and 60 mL/min injecting into a partially cased borehole allow for fully contained fracturing treatments. A six sensor acoustic emission (AE) array is used for geometric fracture location estimation …

    colo-mines Repository record for Laboratory simulation of an enhanced geothermal reservoir (opens in a new tab)

  18. Surface acoustic wave microfluidic pumps for on-chip diagnostics

    … is done via bulky benchtop equipment such as syringe pumps, peristaltic pumps and pressure systems. However, integration of a pumping unit onto the device allows for increased portability and decreased footprint of the device. Although there are multiple examples of realised micropumps based …

    whiterose Repository record for Surface acoustic wave microfluidic pumps for on-chip diagnostics (opens in a new tab)

  19. A remotely operable convection-enhanced thermo-therapy catheter system for broad distribution of therapeutics in the brain

    … has the ability to remotely operate 6 lasers, 6 syringe pumps, 6 individual microneedles, and the primary cannula of the arborizing catheter. Additionally, the software collects pressure sensor data, and the most recent revision has the capability of pressure control

    texas Repository record for A remotely operable convection-enhanced thermo-therapy catheter system for broad distribution of therapeutics in the brain (opens in a new tab)

  20. Development of engineered heart tissues with sacrificial alginate-fibrinogen bioink using low-cost open-source 3D bioprinter

    … the thermal extrusion nozzle with custom syringe pumps. The print fidelity was characterized using alginate ink and gelatin support bath. Functional tissues were printed using induced pluripotent stem cells differentiated cardiomyocytes (iPSC-CM) embedded in bioink containing sacrificial …

    ubc Repository record for Development of engineered heart tissues with sacrificial alginate-fibrinogen bioink using low-cost open-source 3D bioprinter (opens in a new tab)

Page 1 of 3