Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 180 for “"syringes"”

  1. Hot-melt Extrusion Through Syringes

    … for early formulation screens. Plastic and glass syringes are readily available in most laboratories. 250 mg of drug-polymer blend is placed in a plastic syringe body that has the tip covered with a bent needle. The syringe is heated for 5 minutes and the extrudate is pushed through the syringe. …

    arizona-thes Repository record for Hot-melt Extrusion Through Syringes (opens in a new tab)

  2. A Benchtop Robotic Automation Approach for Manufacturing Prefilled Syringes

    … cyclic olefin copolymer (COC) polymer syringes. A Siemens programmable logic controller (PLC) system is developed to interface with the robot (through the St¨aubli Robotic Suite (SRS)) and the Nema-17 motor-driven Cartesian gantry platform. Automated filling of a tray of 50ml syringes …

    clemson Repository record for A Benchtop Robotic Automation Approach for Manufacturing Prefilled Syringes (opens in a new tab)

  3. Benefits and Barriers of Using Prefilled Precedex Syringes in the Operating Room: A Cost Comparison

    … the benefit of prefilled ready-to-administer syringes, but the cost of this medication preparation versus traditional vial and syringe preparation is of concern of administration at this facility. A PICO question was developed for this project: In operative patients receiving Precedex (P), how …

    wvu Repository record for Benefits and Barriers of Using Prefilled Precedex Syringes in the Operating Room: A Cost Comparison (opens in a new tab)

  4. ASSESSMENT OF MATERIAL INTERFACE EFFECTS ON BIOPHYSICAL STABILITY OF DRUG PRODUCTS IN PRE-FILLED SYRINGES

    Pre-filled syringes (PFS) are an increasingly popular device format for parenteral drug delivery due to their convenience and ease of administration. However, their high surface-area-to-volume ratio exacerbates interfacial interactions between the drug product (DP) and syringe components. In …

    jhu Repository record for ASSESSMENT OF MATERIAL INTERFACE EFFECTS ON BIOPHYSICAL STABILITY OF DRUG PRODUCTS IN PRE-FILLED SYRINGES (opens in a new tab)

  5. Factors Influencing Pharmacy Students' Intention to Sell Syringes to Suspected Injection Drug Users In Community-Based Pharmacies

    Providing access to sterile syringes, through pharmacy-based syringe sales, is considered an important part of a comprehensive approach to HIV/AIDS prevention among injection drug users (IDUs). Pharmacists are the gatekeepers for such sales and thus, formal pharmacy education can potentially play a …

    south-carolina Repository record for Factors Influencing Pharmacy Students' Intention to Sell Syringes to Suspected Injection Drug Users In Community-Based Pharmacies (opens in a new tab)

  6. Syringes and Speculums: Unveiling Medical Practices at Sea During the Transatlantic Slave Trade Era, 1700s and 1800s

    … Trade with an emphasis on the use of tools like syringes and speculums. The medical implications of the slave trade are still poorly understood, despite the economic and social aspects having gotten a lot of attention. Using material culture from archaeological assemblages, historical documents, …

    ecu Repository record for Syringes and Speculums: Unveiling Medical Practices at Sea During the Transatlantic Slave Trade Era, 1700s and 1800s (opens in a new tab)

  7. Internship Reports and Monograph Entitled"Prefilled syringes, prefilled pens and auto-injectors: exploring the application on auto-immune diseases"

    … this review describes the history of prefilled syringes (PFS), prefilled pens (PFP) and auto-injectors (AI) as a promising technology that expands the parenteral route to the population, so that it can be administered outside the hospital setting. Later on, we also explore the added value that …

    coimbro Repository record for Internship Reports and Monograph Entitled"Prefilled syringes, prefilled pens and auto-injectors: exploring the application on auto-immune diseases" (opens in a new tab)

  8. Using the theory of planned behavior to predict Texas community pharmacists' willingness to provide sterile syringes to known or suspected intravenous drug users

    … pharmacists’ willingness to provide sterile syringes to known or suspected intravenous drug users (IDUs). The study explored the utility of the TPB constructs (attitude, subjective norm, perceived behavioral control) and recent past behavior to predict willingness to provide sterile syringes …

    texas Repository record for Using the theory of planned behavior to predict Texas community pharmacists' willingness to provide sterile syringes to known or suspected intravenous drug users (opens in a new tab)

  9. Behavioral and Community Impacts of the Portland Needle Exchange Program

    … Drug Injectors Use An Exchange In A StateWhere Syringes Are Legal? 2: Will Drug Injectors Using An Exchange Decrease Risky Behavior? 3: Will Frequent Clients Change Risk Behaviors More Than Infrequent Clients? 4: Will Drug Injectors Using An Exchange Change Risk Behaviors More Than A Comparison …

    portland-state Repository record for Behavioral and Community Impacts of the Portland Needle Exchange Program (opens in a new tab)

  10. DESIGN AND DEVELOPMENT OF A VARIABLE-DOSING DRUG DELIVERY DEVICE WITH A NEEDLE-STICK SAFETY MECHANISM

    … pressing. Consequently, the demand for prefilled syringes has surged recently. These syringes, which also serve as drug containers, require a more involved manufacturing process than traditional syringes. The complexity of drug filling and syringe finishing processes makes it expensive and in some …

    jhu Repository record for DESIGN AND DEVELOPMENT OF A VARIABLE-DOSING DRUG DELIVERY DEVICE WITH A NEEDLE-STICK SAFETY MECHANISM (opens in a new tab) Embargoed until 2028-05-01

  11. Ιατροκοινωνικοί παράγοντες που επηρεάζουν τη διασπορά λοίμωξης από HIV στους τοξικομανείς

    … stated that they mainly obtain the needles and syringes from chemist's shops. The 61.8% of the men and 56.7% of the women never use used needles and syringes. The IV.DUs that use used needles and syringes borrow them mainly from friends or their sexual partners and 61.7% always clean them before …

    greece Repository record for Ιατροκοινωνικοί παράγοντες που επηρεάζουν τη διασπορά λοίμωξης από HIV στους τοξικομανείς (opens in a new tab)

  12. Análise térmica de uma resina composta de nanopartículas: caracterização e envelhecimento

    … (TMA). In group 1, 15 analyses throughout syringes were carried without pressing the pestle screw. In groups 2 and 3, the composite resin was all pressed out by the pestle screw and divided in five portions. However, in group 2, throughout the time, the syringes had been kept in the …

    brazil-ufmg Repository record for Análise térmica de uma resina composta de nanopartículas: caracterização e envelhecimento (opens in a new tab)

  13. A Tale of Two Studies: A Biomechanical Comparison of Extrapelvic and Intrapelvic Fixation for Acetabular Fractures among the Elderly and a Comparison of Dosage Accuracy and Precision for Traditional and Incremental Syringes

    Elderly patients represent the fastest growing population in sustaining acetabular fractures. Anterior column with posterior-hemitransverse (ACPHT) fractures are one of the most common types of acetabular fractures seen in the elderly. Extrapelvic and intrapelvic fixations are used as surgical …

    wfu Repository record for A Tale of Two Studies: A Biomechanical Comparison of Extrapelvic and Intrapelvic Fixation for Acetabular Fractures among the Elderly and a Comparison of Dosage Accuracy and Precision for Traditional and Incremental Syringes (opens in a new tab)

  14. Quantifying the Ergonomic Impact on Healthcare Workers Using a Needle-free Injector Device

    … previously analyzed retractable intramuscular syringes with needles. Finally, the third objective was to assess potential psychophysics ergonomic impact on HCWs with use of these devices to formulate future design changes and recommendations for manufacturers and HCWs, respectively. Methods: …

    usf Repository record for Quantifying the Ergonomic Impact on Healthcare Workers Using a Needle-free Injector Device (opens in a new tab)

  15. Experiences Of Transgender People Filling Prescriptions In Community Pharmacies

    … with obtaining the correct needles and/or syringes for participants using injectable hormones. Moreover, based on the professional experience of the author, systemic issues related to pharmacy software introduce difficulty and multiple opportunities for error when processing prescriptions …

    umn Repository record for Experiences Of Transgender People Filling Prescriptions In Community Pharmacies (opens in a new tab)

  16. Determining the effectiveness of harm reduction interventions in the prevention of hepatitis C virus transmission among people who inject drugs in Scotland

    … between self-reported sharing of needles/syringes and incident/prevalent HCV infection; (iii) to determine the association between sharing non-needle/syringe injecting paraphernalia and incident HCV infection; (iv) to determine the incidence of HCV among PWID in Scotland; and (v) to …

    glasgow Repository record for Determining the effectiveness of harm reduction interventions in the prevention of hepatitis C virus transmission among people who inject drugs in Scotland (opens in a new tab)

  17. Optimization of a Dual-Chamber Syringe for Intravenous Therapy Administration: Definition of Functional Requirements and Conceptual Design Development

    … and flushing solution without the need to switch syringes. In this way, it reduces the number of syringes used, minimizes catheter manipulation, and decreases associated complications. However, pre-clinical studies with this syringe revealed functional limitations, namely fluid migration between …

    coimbro Repository record for Optimization of a Dual-Chamber Syringe for Intravenous Therapy Administration: Definition of Functional Requirements and Conceptual Design Development (opens in a new tab)

Page 1 of 9