Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 64 for “"system transfer"”.

  1. Correlation Techniques Applied to Power System Transfer Function Determination

    In electrical power systems, particularly those operating near the stability limit, it would be desirable to determine a mathematical description of the system elements without disturbing the system by test signals. This thesis presents a method of achieving this result by applying correlation …

    sask Repository record for Correlation Techniques Applied to Power System Transfer Function Determination (opens in a new tab)

  2. Superresolution applied to optical data storage systems

    … applications in optical data storage systems. The performance of standard and superresolving magneto-optic data storage system are quantified by scalar diffraction modeling and experiments. Classical resolution measures are reviewed. Background on superresolution definitions and their …

    arizona-thes Repository record for Superresolution applied to optical data storage systems (opens in a new tab)

  3. Measurement and analysis optimization of large aperture laser Fizeau interferometer

    High-power laser systems, such as the National Ignition Facility (NIF) project at Lawrence Livermore National Laboratories (LLNL), require optics of extremely high quality. Surface errors, especially periodic surface relief structures, can lead to focal spot degradation at best and serious damage …

    arizona-thes Repository record for Measurement and analysis optimization of large aperture laser Fizeau interferometer (opens in a new tab)

  4. RESTORATION FOR SAMPLED IMAGING SYSTEMS.

    … of the continuous output of an imaging system to a discrete array, further degrades or blurs the image. Thus, incorporating sampling effects into the restoration should improve the quality of the restored image. The system transfer function (the Fourier transform of the point spread …

    arizona-thes Repository record for RESTORATION FOR SAMPLED IMAGING SYSTEMS. (opens in a new tab)

  5. A digital simulation of a dual-duct air handling system

    … digital simulation of a dual-duct air handling system. The individual control loops and system components of the dual-duct system which was studied are explained in detail. The testing and data recording devices used in the investigation are described. An appropriate model for the system …

    ut-knoxville Repository record for A digital simulation of a dual-duct air handling system (opens in a new tab)

  6. Modeling and Simulation of a Cascaded Three-Level Converter-Based SSSC

    … of static series synchronous compensator (SSSC) systems utilizing cascaded-multilevel converters (CMCs). Among flexible AC transmission system (FACTS) controllers, the SSSC has shown feasibility in terms of cost-effectiveness in a wide range of problem-solving abilities from transmission to …

    vt Repository record for Modeling and Simulation of a Cascaded Three-Level Converter-Based SSSC (opens in a new tab)

  7. A nuclear magnetic resonance proton magnetometer

    … is utilized in the sensing unit of a feedback system, the feedback current being recorded as a measure of the geomagnetic variation. The thesis establishes the feasibility of a feedback system magnetometer. The system transfer function is derived and from it the sensitivity, stability, steady …

    ubc Repository record for A nuclear magnetic resonance proton magnetometer (opens in a new tab) Download PDF for A nuclear magnetic resonance proton magnetometer (opens in a new tab)

  8. DELTAMODULATION FOR THE RECORDING AND TRANSMISSION OF ANALOG BIOMEDICAL DATA

    … of the delta signal is predictable once the system transfer function of the transmission medium is given; therefore, the maximum transmission bandwidth can be determined. The system linearity is also investigated. It is concluded that the deltamodulation is not a linear process. The results …

    sask Repository record for DELTAMODULATION FOR THE RECORDING AND TRANSMISSION OF ANALOG BIOMEDICAL DATA (opens in a new tab)

  9. Ultrasonic system models and measurements

    … important elements of an ultrasonic measurement system as well as the entire system. Ultrasonic measurement models for predicting the response from reference reflectors are described, including a new ultrasonic measurement model recently developed to simulate the ultrasonic response of an …

    iastate Repository record for Ultrasonic system models and measurements (opens in a new tab)

  10. Frequency domain system identification of fixed-wing unmanned aerial vehicles

    … thesis is to identify airplanes’ reduced order transfer functions, and aerodynamic derivatives in the longitudinal channel. The outcome of the research will benefit aircraft systems’ controller design, modeling and simulation. To identify the system transfer functions and aerodynamic …

    manitoba Repository record for Frequency domain system identification of fixed-wing unmanned aerial vehicles (opens in a new tab)

  11. The development of signal processing techniques for the noise reduction and classification of partial discharge

    … (pole-zero model) is introduced, to estimate the system transfer function such that the impulse response of the estimated transfer function approximately matches the original partial discharge waveform. Step-response features were extracted from the estimated system transfer function to …

    unsw Repository record for The development of signal processing techniques for the noise reduction and classification of partial discharge (opens in a new tab)

  12. Techniques for optical binary multiplication

    … frequency analysis developed for communication Systems were applied to analyze optical imaging Systems and then to synthesize desired System transfer functions. The Fourier Transform relationship which exists between the light amplitude distributions at the front and back focal planes of a lens …

    ttu Repository record for Techniques for optical binary multiplication (opens in a new tab)

  13. An investigation of a mathematical model to characterize the nonlinear nature of a lithographic film system

    An attempt was made to obtain a set of spatial transfer functions which would allow the prediction of output effective exposure distributions for a nonlinear lithographic film system. Slit exposures were used as one-dimensional system inputs. It was proposed that the use of slits would allow the …

    rit Repository record for An investigation of a mathematical model to characterize the nonlinear nature of a lithographic film system (opens in a new tab)

  14. Open-loop frequency response analysis of a jacketed kettle with internal heating/cooling coil

    … coils and glasteel thermowell. This system was first analyzed mathematically by deriving transfer functions for each component and then combining all component equations together to give the overall system transfer function. The mathematical model was then checked by frequency …

    njit Repository record for Open-loop frequency response analysis of a jacketed kettle with internal heating/cooling coil (opens in a new tab)

  15. Space-variant processing using phase codes and Fourier-plane sampling techniques

    Any slowly varying linear space-variant system can, in principle, be represented holographically by spatially sampling the input plane and multiplexing the respective system transfer functions. A scheme reported earlier for implementing this technique makes use of phase diffusers in the reference …

    ttu Repository record for Space-variant processing using phase codes and Fourier-plane sampling techniques (opens in a new tab)

  16. AN FFT SPECTRAL ANALYSIS FOR SYSTEM IDENTIFICATION

    With the advent of, larger am more complex systems being used in industry the requirement for more accurate estimates of the system operating parameters becomes greater. One method of obtaining these operating parameters is by the use of the information contained in the spectral density functions …

    sask Repository record for AN FFT SPECTRAL ANALYSIS FOR SYSTEM IDENTIFICATION (opens in a new tab)

  17. Implementation of a digital control system analysis program using the z-transform

    Control system design and analysis is computationally complex and includes a wide range of tools to aid the engineer. For discrete systems the z-transform is one such tool. This paper discusses the development and application of a computer program which utilizes the z-transform in the analysis of …

    eastern-wash Repository record for Implementation of a digital control system analysis program using the z-transform (opens in a new tab)

  18. DACS: an interactive computer program to aid in the design and analysis of linear control systems

    … in the design and analysis of linear control systems. Written in compiled basic, DACS includes Root Locus, Bode plots, Nyquist diagrams, Nichols charts, system simulation, and calculates the system time response in closed-form. The state-space description is used in the simulation and time …

    vt Repository record for DACS: an interactive computer program to aid in the design and analysis of linear control systems (opens in a new tab)

  19. The importance of sediment roughness on the reflection coefficient for normal incidence reflections

    … at Austin. A single beam echo-sounder (SBES) system was developed to project and receive a wideband (3 kHz to 30 kHz) acoustic pulse. A method was developed using the system transfer function to create a custom pulse that would minimize the dynamic range over the wide frequency band. A matched …

    texas Repository record for The importance of sediment roughness on the reflection coefficient for normal incidence reflections (opens in a new tab)

  20. Quality assurance studies for collection of whole air samples in stainless steel canisters, for volatile organic compound determinations

    … sources in the whole air sampling and analyzing system have been identified. They are the canister internal adsorption, the whole system transfer line, the air pump and the filter. The optimigation of the canister cleaning process is described. Blanking procedures for the canisters and the entire …

    njit Repository record for Quality assurance studies for collection of whole air samples in stainless steel canisters, for volatile organic compound determinations (opens in a new tab)

Page 1 of 4