Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 90 for “"t junction"”.
-
Droplet formation on demand at a microfluidic T-junction
… can be formed continuously in a microfluidic T-junction when two input flows of immiscible fluids are maintained. However, it is difficult to form stable air separated aliquots in a simple T-junction configuration. Electrowetting-on-dielectric (EWOD) is commonly used to control individual …
-
Alginate fiber production using co-flow at a milli-fluidic t-junction
In this thesis work, we introduce a new technique for the continuous production of alginate fibers that utilizes just syringe pumps, plastic tubing and a tee tube fitting. Alginate fibres of controlled diameter are produced by adjusting the flowrates of sodium alginate and calcium chloride …
-
Dynamics of Elastic Capsules in Cross-Junction and T-Junction Microfluidic Channels
… membrane) in two microfluidic channels of cross-junction and T-junction geometries. For the cross-junction microfluidic channel, we consider an initially spherical capsule with a size smaller than the cross-section of the square channels comprising the cross-junction, and investigate the effects …
-
Phase distribution of a refrigerant two-phase flow over an impacting T-junction
… This geometry can be reduced to an impacting T-junction. An impacting T-junction is a T-junction of which the two outlets are perpendicular to the inlet tube. The purpose of this work is to fill the gaps in literature concerning the phase distribution over an impacting T-junction and to develop …
-
Simulation of Ternary Fluid Systems in T-junction Microfluidics Devices with Lattice Boltzmann Method
Microfluidic systems have emerged as a transformative technology, enabling precise manipulation of fluids at the microscale with applications spanning drug delivery, chemical synthesis, and biomedical diagnostics. These systems rely on the controlled generation and manipulation of droplets, …
-
Experimental and Theoretical Study of Droplet Formation at a T-junction with Xanthan Gum Solutions
… droplet formation process at a microfluidic T-junction employing xanthan gum solutions that exhibit shear thinning behaviour. The effects of the controlling parameters such as the flow rate, viscosity and inlet angles of the T-junction as well as xanthan gum concentrations were experimentally …
-
Single Molecule Studies of ssDNA Dynamics Near a DNA (p/t) Junction and Their Role in Protein Nucleic Acid Interactions of the T4 Bacteriophage.
… near ss—double-stranded (ds) DNA junctions proceeds through a transiently bound monomer, which does not slide along ssDNA. I developed methods to analyze the single-molecule signal at sub-millisecond resolution, which led to new insights into the nature of ssDNA fluctuations as …
-
MODELING AND OPTIMIZATION OF THE MICROSPHERE GENERATION PROCESS
… with their corresponding devices, the modified T-junction device and membrane emulsification device, are studied in this dissertation, because of their unique features, with the former having an excellent task flexibility and the latter having an excellent efficacy. The study defined three …
-
Numerical analysis of blood flow in an aortocoronary bypass model
… $D_2/D_1 < 1$, with or without blend at the junction) include T-junction and host to branch junction with a radius of curvature with and without helical pitch. Some flow conditions included non-Newtonian blood and non-steady flow. Non-blended T-junction is subjected to flow separation at the …
-
Exploring Microfluidic Design Automation: Thin-wall Membrane Regulator
… it focuses on the automated synthesis of T-junction components with thin-walled membranes for stability. A T-junction is a passive droplet generation component, common in microfluidics which suffers from behavior instability in highly integrated circuits with many components. One way of …
-
Caracterização experimental da separação gás-líquido em uma junção do tipo T inclinada
The two-phase flows at a T-Junction is a common feature in many industrial processes, such as oil field flow lines, pipeline networks and refinery streams to divide or combine flows. When a gas-liquid mixture flows through a junction, the phases can be separated unevenly such that the qualities in …
-
Blood Flow Simulation of Particle Trapping in Models of Arterial Bifurcations
… models. For validation of CFD calculations, a T-junction model and a Y-junction model are analyzed. In both the models, there is one inlet pipe with two outlet pipes creating a symmetric bifurcation at some angle from the centerline of the inlet pipe. Naiver-Stokes (RANS) equations are solved for …
-
CFD simulations on EGR mixing in the inlet manifold of a combustion engine
… simulations were conducted on a simple T-junction in order to analyze how different parameters affect the mixing process. Data from a reference case involving a mixing experiment was used in order to verify the CFD simulations on the T-junction. The optimal settings from the T-junction …
-
Droplet Production and Transport in Microfluidic Networks with Pressure Driven Flow Control
… purpose, a model system consisting of a single T-junction droplet generator and a single network node is used to understand how pressure source control effects droplet generation and transport through microfluidic networks. The first part of this thesis focuses on the generation of Newtonian …
-
Modelling the folding pathway of DNA nanostructures
… origami through simulations: a reconfigurable T-junction origami, several traditional origami, and origami with coated scaffolds.</p> <p>The T-junction origami is intended as an economically feasible method of changing the uniqueness of interactions. My contribution to this work is to …
-
Millimetre and sub-millimetre wave input couplers for gyrotron travelling wave amplifiers
… within the gyro-TWA.;The design of 1) a T-junction fundamental mode rectangular to- circular waveguide input coupler, 2) a multiple-hole input coupler and 3) a higher order mode (HOM) input coupler for a low-terahertz gyrotron travelling wave amplifier were studied. The T-junction input …
-
Droplets generation and sampling on demand with peristaltic pumping systems
… physics. Droplets are normally generated in a T-junction or flow-focusing with syringe pumps or other pressure sources. An alternative way to generate droplets is to sequentially aspirate aqueous samples and carrier oil under negative pressures. Both of the typical T-junction methods and the …
-
On Multiphase Flow Models in ANSYS CFD Software
… concerning air-water mixtures in a vertical T-junction with horizontal branch. When a gas-liquid mixture flows into a branching pipe junction phase redistribution will occur and a higher proportion of gas will enter the side branch. The aim of the simulations was to find models/settings that …
-
GABAergic Signalling in the Peripheral Somatosensory System: Local and Multicellular Mechanisms Underlying Sensory Modulation
… In particular, the axonal bifurcation, or T-junction, functions as a frequency-dependent filter regulating the transmission of sensory signals from the periphery to the spinal cord. While nociceptive processing has traditionally been considered neuron-centric, increasing evidence indicates …
Page 1 of 5