Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 6 of 6 for “"table-top system"”.

  1. Periodic metallic nanostructures fabricated by coherent Talbot lithography in a table top system

    … (EUV) lithography. A compact nanofabrication system that combines Talbot lithography and a table top extreme ultraviolet laser illumination is presented. The lithographic method based on the Talbot effect provides a robust and simple experimental setup that is capable to print arbitrary …

    colostate Repository record for Periodic metallic nanostructures fabricated by coherent Talbot lithography in a table top system (opens in a new tab)

  2. Prospects for single shot diffraction imaging with laser-plasma driven high harmonic sources

    … of high order harmonics generated from laser systems, high harmonic generation (HHG) remains one of the key routes to an intense, spatially coherent source of XUV radiation. The work presented in this thesis presents the numerical investigations conducted using the parallelized, second order …

    qu-belfast Repository record for Prospects for single shot diffraction imaging with laser-plasma driven high harmonic sources (opens in a new tab) Download PDF for Prospects for single shot diffraction imaging with laser-plasma driven high harmonic sources (opens in a new tab)

  3. Gamma-Ray Optical Studies of ⁷³Ge and ⁵⁷Fe

    … necessary for such an observation with any isotope were documented. The procedures necessary for testing the crystal samples for the ability to support a Borrmann effect, both prior to and after the introduction of the parent nuclei, were derived for both a table-top x-ray system and a …

    odu Repository record for Gamma-Ray Optical Studies of ⁷³Ge and ⁵⁷Fe (opens in a new tab)

  4. A Miniaturized Multi-Modality imaging system for Dielectric Materials Evaluation

    … and the lack of compact and accurate imaging systems that are not prohibitively expensive for the frequency range (10 KHz to 9 GHz), low frequency capacitive imaging and high frequency microwave imaging have been chosen as the modalities for the system presented in this thesis. First, the …

    msu Repository record for A Miniaturized Multi-Modality imaging system for Dielectric Materials Evaluation (opens in a new tab)

  5. Design, Fabrication and Validation of a CMOS-MEMS Kelvin Probe Force Microscope

    … a strain gauge such that a conventional optical system will not have to be employed. The ability to use integrated bimorph actuators on chip allow for movement of the cantilever without the employment of large piezoelectric stages with creep effects. Embedded electronics can be fabricated with …

    waterloo Repository record for Design, Fabrication and Validation of a CMOS-MEMS Kelvin Probe Force Microscope (opens in a new tab)

  6. Contrast agent imaging using an optimized table-top x-ray fluorescence and photon-counting computed tomography imaging system

    … these contrast agents in trace amounts at acceptable imaging time and radiation dose. Two such imaging techniques include x-ray fluorescence computed tomography (XFCT) and photon-counting CT (PCCT). XFCT combines the principles of CT with x-ray fluorescence by detecting fluorescent x-rays from …

    uvic Repository record for Contrast agent imaging using an optimized table-top x-ray fluorescence and photon-counting computed tomography imaging system (opens in a new tab)