Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 72 for “"tangential flow filtration"”

  1. Tangential Flow Filtration for the Purification of Lucentis

    … protein. This group has been working on the tangential flow filtration (TFF) portion of the project, which will be utilized multiple times throughout the separation and purification process. The primary purpose of tangential flow filtration is to exchange buffer solution. Exchanging buffer …

    unr Repository record for Tangential Flow Filtration for the Purification of Lucentis (opens in a new tab)

  2. Feasibility of critical mineral enrichment using tangential-flow filtration

    … Saint Lawrence Columbium mine at Oka, Québec. Tangential-flow filtration separated material using 0.65 µm, 0.22 µm and 100 kDa membranes and produced concentrated retentate fractions. The greatest enrichment generally occurred in the 0.65 µm retentates, which contained ΣREE and Nb …

    queens Repository record for Feasibility of critical mineral enrichment using tangential-flow filtration (opens in a new tab)

  3. Highly Efficient Click-Coupling of Hemoglobins Followed by Purification Using Tangential Flow Filtration

    … of bis-tetramer purification, I applied tangential flow filtration, a continuous, scalable process widely used in industry to remove impurities in solutions. I developed a two-stage purification to separate bis-tetramers from protein aggregates and unreactive tetrameric hemoglobin after …

    toronto-retro Repository record for Highly Efficient Click-Coupling of Hemoglobins Followed by Purification Using Tangential Flow Filtration (opens in a new tab)

  4. Simultaneous clarification and purification of recombinant penicillin G acylase using tangential flow filtration anion-exchange membrane chromatography

    … culture broth was applied directly to a tangential flow filtration anion-exchange membrane chromatography system. One-step purification of recombinant PAC was achieved based on the dual nature of membrane chromatography (i.e. microfiltration-sized pores and anion-exchange chemistry). Due …

    waterloo Repository record for Simultaneous clarification and purification of recombinant penicillin G acylase using tangential flow filtration anion-exchange membrane chromatography (opens in a new tab)

  5. Scaled-up Purification of Poly(acrylic acid)-Block-Polystyrene Nanoparticles Using Tangential Flow Filtration: A Feasibility Study

    … aqueous system. Here, the feasibility of using tangential flow filtration (TFF) to scale-up the solution-state transition was studied. A custom-designed and chemically resistant experimental TFF system was built. Nine TFF experiments were performed to study the effects of change of transmembrane …

    tamu Repository record for Scaled-up Purification of Poly(acrylic acid)-Block-Polystyrene Nanoparticles Using Tangential Flow Filtration: A Feasibility Study (opens in a new tab)

  6. Modelling and prediction of non-linear scale-up from an Ultra Scale-Down membrane device to process scale tangential flow filtration

    … of small scale devices such as the stirred cell filtration units have been primarily limited to preliminary testing and initial screening due to their geometric and flow dissimilarities to tangential flow filtration at scale. As a result, process development and optimisation trials are generally …

    ucl Repository record for Modelling and prediction of non-linear scale-up from an Ultra Scale-Down membrane device to process scale tangential flow filtration (opens in a new tab)

  7. Cloud Point Extraction in Conjunction with Tangential Flow Filtration (CPE-TFF) for the Enhanced Separation of Silver Nanoparticles and Silver Ions from Aqueous Colloids and Biological Matrices

    … cloud point extraction (CPE) was combined with tangential flow filtration (TFF) for the enhanced separation of AgNPs and Ag+ from aqueous colloids and biological matrices. The feasibility of the CPE-TFF method was demonstrated on four colloidal (borohydride-, PVP-, citrate-capped and uncapped …

    ohiolink Repository record for Cloud Point Extraction in Conjunction with Tangential Flow Filtration (CPE-TFF) for the Enhanced Separation of Silver Nanoparticles and Silver Ions from Aqueous Colloids and Biological Matrices (opens in a new tab)

  8. Quantitative assessment of methods for bacterial and viral purification and concentration

    … the applicability of syringe filters and a tangential flow filtration device for the purification and concentration of bacteria and virus samples, respectively. Furthermore, automation of such systems were explored. We developed a fully automated method for double filter filtration to enable …

    gatech Repository record for Quantitative assessment of methods for bacterial and viral purification and concentration (opens in a new tab)

  9. Comparison of Tissue Contractile Responses of Rat Models of Pulmonary Artery Hypertension and Type I/II Diabetes

    … homogenizer, centrifuge, column chromatography, tangential flow filtration. Specifications for these units will be determined using data from either literature research or experimentation. A sample of bacteria culture that has been processed through a homogenizer and centrifuge were obtained and …

    unr Repository record for Comparison of Tissue Contractile Responses of Rat Models of Pulmonary Artery Hypertension and Type I/II Diabetes (opens in a new tab)

  10. The extraction and partial purification of transfer factor from human urine.

    … with blood to extract TF. In the second study, tangential flow filtration combined with stirred cell final filtration and dual acetone precipitation required only 10 hours to produce TF activity nearly identical to the first study. The stirred cell and acetone procedure could also be used to …

    arizona-thes Repository record for The extraction and partial purification of transfer factor from human urine. (opens in a new tab)

  11. Performance and Fouling during Bioreactor Harvesting

    Tangential flow filtration has many advantages for bioreactor harvesting as the permeate could be introduced directly to the subsequent capture step, the process is easy to scale up, and fouling of the filter is limited by the cross flow. However, membrane fouling has limited its widespread use. …

    arkansas Repository record for Performance and Fouling during Bioreactor Harvesting (opens in a new tab)

  12. Novel approaches to the purification of plasmid DNA for therapeutic application

    … use of an integrated unit operation, comprising tangential-flow filtration coupled with the adsorption of contaminants onto nitrocellulose membranes as a single processing step was then examined, and indicated the utility of the operation to adsorb ssDNA and proteins from model solutions. …

    ucl Repository record for Novel approaches to the purification of plasmid DNA for therapeutic application (opens in a new tab)

  13. Isolation of bacteria from positive blood cultures by filtration to facilitate rapid identification and antimicrobial susceptibility testing in sepsis diagnostics

    … To reduce time to results, a method based upon tangential flow filtration was developed to isolate viable bacteria from a positive blood culture in a matter of minutes. This method produces a bacteria suspension that excludes blood cells and analytes, allowing the sample to be used in subsequent …

    jhu Repository record for Isolation of bacteria from positive blood cultures by filtration to facilitate rapid identification and antimicrobial susceptibility testing in sepsis diagnostics (opens in a new tab)

  14. OPTIMIZED SYNTHESIS AND PURIFICATION STEPS FOR ULTRASMALL FLUORESCENT CORE-SHELL SILICA NANOPARTICLES WITH APPLICATIONS IN NANOMEDICINE

    … developed an optimized, scalable synthesis workflow by increasing precursor concentration fivefold while elevating the reaction pH to counteract increased silicic acid formation and maintain controlled condensation kinetics. Standard bioanalytic techniques were used to characterize the C’dot …

    cornell Repository record for OPTIMIZED SYNTHESIS AND PURIFICATION STEPS FOR ULTRASMALL FLUORESCENT CORE-SHELL SILICA NANOPARTICLES WITH APPLICATIONS IN NANOMEDICINE (opens in a new tab)

  15. Investigating the cardioprotective potential of exosomes from different cellular sources

    … of by size exclusion chromatography and tangential flow filtration were highly variable. Therefore, a novel isolation method was established in which exosomes were affinity purified by immune-pulldown of an epitope tag transiently expressed in cells in culture. This method allows the …

    ucl Repository record for Investigating the cardioprotective potential of exosomes from different cellular sources (opens in a new tab)

  16. Optimization of Downstream Processing of a Monoclonal Antibody

    … the product. The final step of the process is tangential flow filtration. This removes any additional impurities and prepares Lucentis for clinical use.

    unr Repository record for Optimization of Downstream Processing of a Monoclonal Antibody (opens in a new tab)

  17. Optimization of Downstream Purification of Lucentis

    … (TOSOH Bioscience) resins followed by a 30 kDa tangential flow filtration (TFF) cassette (Pall Corp). Alternative case 1 consisted of a multimodal resin (hydrophobic and cation exchange) followed by a TFF unit, hydrophobic interaction exchange resin column, and another TFF unit. This specific …

    unr Repository record for Optimization of Downstream Purification of Lucentis (opens in a new tab)

  18. TANGENTIAL FLOW ULTRAFILTRATION AS AN ANTIFOULING STRATEGY FOR WATER QUALITY SENSORS

    … were integrated in a customized flat sheet Tangential Flow Filtration (TFF) device with an ultrafiltration membrane and placed on the permeate side of the filtration device. The decrease in the sensitivity noted for the pH and DO sensors used with TFF were 5 times lower as compared to when …

    mcmaster Repository record for TANGENTIAL FLOW ULTRAFILTRATION AS AN ANTIFOULING STRATEGY FOR WATER QUALITY SENSORS (opens in a new tab)

  19. Ranaspumin Protein Characterization and Applications for Both Environmental and Medical Purposes

    … achieved in tar-sands with the assistance of a Tangential Flow Filtration (TFF) system. With only three passes through the TFF system, the RSN 2 solution isolated approximately 35% of the aliphatic region, and approximately 70% of the aromatic region. Finally, RSN 2 was implemented into an organ …

    unt Repository record for Ranaspumin Protein Characterization and Applications for Both Environmental and Medical Purposes (opens in a new tab)

Page 1 of 4