Showing 1 to 15 of 15 for “"tapping screw"”.
-
Self-tapping screw assemblies under monotonic and reverse cyclic load
… the performance of newly evolved structural self-tapping full thread wood screws as a primary fastener in Canadian Douglas-fir glulam and Cross-Laminated-Timber. The screws as primary fasteners were investigated in a commonly used shear connection and a recently developed moment resisting assembly …
-
Investigation of brittle failure in steel-to-CLT self-tapping screw connections
Self-tapping screws (STSs) are becoming increasingly popular in the mass timber construction industry due to their ease of installation, high load-carrying capacity, and suitability for prefabrication. While the new STS provision in CSA O86-24 covers both ductile and brittle failure modes for …
-
Flexural Strength and Behavior of Timber-Concrete Composite Floors with Hexagonally Headed Self-Tapping Screw Shear Connectors
… concrete top layer using hexagonally headed self-tapping screw shear connectors. To accomplish the objective, coupon specimens and full-scale TCC floor panels were tested, and a finite element modelling approach was developed. The coupon tests were used to determine the stiffness of the shear …
-
Seismic design and performance evaluation of balloon-type CLT shear walls in Canada
… 24 archetypes which use mixed-angle self-tapping screw hold-downs. The archetypes vary in wall length (3 m and 6 m) and building height (6 to 12 storeys), and are located in three Canadian cities (Montreal, Vancouver, and Victoria). The archetypes were designed with a range of R values …
-
Expedient moment connections for timber portal frame buildings
… from first principles. The fully threaded self-tapping screw capacity and slip values are the only exception. These have been determined by testing. Due to the inherent simplicity of the connection, it is adaptable for use as a column base, knee, splice and apex connection. The use of the …
-
Experimental Testing and Numerical Modeling of a Novel Buckling Restrained Connection for Mass Timber Structures
… with conventional connection types (i.e., screws or bolts) that is also fully concealed. Furthermore, by introducing a mechanical coupler between the glued-in rod and the axial fuse, the connection becomes replaceable as the axial fuse(s) could be replaced following an earthquake given the …
-
Structural Behaviour of Pre-Engineered Beam-Hanger Connections for Mass Timber and Hybrid Mass Timber-Steel Structures
… are fastened to the timber elements using self-tapping screws. While these connections are relied upon to transfer shear, they must also have sufficient rotational capacity to withstand a design-level earthquake without losing their load-carrying capacity. This research investigates the …
-
Investigating the Response of Bolted Wood Connections Subjected to Bast Loads
… wood crushing. It was found that the use of self-tapping screw reinforcement was an effective method of preventing premature splitting failures and enhancing the performance of a connection. The results showed that connections which engaged the fastener in bending exhibited more favourable …
-
Reinforced Timber Laminated Veneer Lumber (LVL) Connection Loaded Perpendicular to the Grain
… the splitting resistance by inserting self-tapping screws. In the first phase, AS/NZS 4063.1-2010 tensile tests were conducted on LVL samples of two lengths using a three-point bending set-up. The load, deflection, stress, strain, and failures of the samples were measured and analyzed to …
-
Experimental investigation of long term and lateral load behavior of CLT shear walls for mid-rise wood buildings
… ultra-high performance concrete and self-tapping screw. Laboratory tests on these two connection show that the connections have very high stiffness (4 times) compared to traditional bracket type ones and they have high strength as high as 3 to 4 times.
-
Experimental Study of Shear Resistance and Failure Behavior of Reinforced and Un-reinforced Notched Cross-Laminated Timber Plates
… various notches and reinforcement using self-tapping screws (STS) were tested in bending in both major and minor strength directions. Un-notched CLT beams under bending primarily failed in rolling shear in the transverse layers. Notches influenced not only the failure mode but also shear …
-
Cyclic Testing of Pre-engineered Beam-Hanger Connections & Reinforcement of Holes in Glulam Beams Using Self-tapping Screws
… of holes in glulam beams using self-tapping screws. Chapter 3 describes laboratory testing of the Megant 430x150x50 beam-hanger connector under applied interstorey drift deflections based on a modified version of the CUREE loading protocol. The performance of the Megant 430x150x50 …
-
Návrh utahovacího momentu šroubového spoje v plastových komponentech
Tato bakalářská práce se zabývá problematikou šroubových spojů v plastových komponentech. V práci jsou obecně popsány šroubové spoje, závity samořezných šroubů, problematika předepjatých spojů a způsoby vyvození požadovaného předpětí. Poznatky byly dále aplikovány na konkrétní šroubový spoj, který …
-
Porovnání spojů používaných pro plastové díly
Bakalářská práce se zabývá technologiemi pro spojování plastových dílů v oblasti konstrukce světlometů. Cílem je se zaměřit a porovnat technologie tavných pinů a samořezných šroubů pro aplikaci spojování optických dílu vyrobených z plastu s deskami plošných spojů obsahující LED. Dále přinést …
-
Seismic assessment of a hybrid light wood-frame structure connected to a balloon-type CLT core
… were connected on the floor level with self-tapping screws (STSs) inserted at 45°, 90°, and mixed angles (45° and 90°). Results show that 45° STSs connections had high stiffness but low energy dissipation, while 90° STS connections had high energy dissipation but low stiffness. Mixed-angle …