Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 118 for “"tapping-mode"”
-
Nonlinear Dynamics of Tapping Mode Atomic Force Microscopy
A mathematical model is developed to investigate the grazing dynamics of tapping mode atomic force microscopes (AFM) subjected to a base harmonic excitation. The nonlinear dynamics of the AFM microcantilever are studied in both of the monostable and bistable phases with the microcantilever tip …
-
Cantilever Dynamic Analysis in Tapping Mode Atomic Force Microscopy
Tapping mode atomic force microscopy (AFM) is becoming popular in the area of biology, as well as for polymer and semiconductor materials science. Unlike other AFM techniques, it only makes intermittent contact with the sample, which largely reduces any potential surface damage to soft materials, …
-
Surface scanning with photonic force microscopy in tapping mode
… the implementation of a new measurement mode of surface imag- ing photonic force microscopy. The aim of the new measurement mode is to make the method more robust in order to extend its field of application and to establish it as a reliable mea- surement method. Photonic force microscopy …
-
Harmonic analysis based identification of tapping-mode AFM dynamics
… power balance techniques are used to analyze the tapping mode dynamics of the atomic force microscope. A non-conservative model for the cantilever sample interaction is developed that can be used for controller design purposes. The harmonic balance perspective explains a number of observations …
-
Estimation of sample location in tapping mode atomic force microscopy
… mechanical properties at the nano-scale. In the tapping mode operation of the AFM, a vibrating cantilever collides intermittently with a sample placed below it. Modeling the tapping process facilitates development of model based control algorithms that can increase the imaging speed and …
-
Linear and nonlinear vibration analysis of tapping mode atomic force microscopy
… microcantilever probe must be accurately modeled in order to generate accurate images and to take accurate readings when using the microcantilever for other applications. Additionally, minimizing the effect of nonlinearities in the dynamic response of the microcantilever allows for less …
-
Non-Smooth Dynamics and Control of Tapping Mode Atomic Force Microscopy
… to a linear impacting oscillator, and a dynamic model of tapping-mode atomic force microscope ensures persistence of the grazing solution trajectory by preventing loss of stability through a discontinuity induced saddle-node bifurcation.
-
Effect of local material properties on tapping mode atomic force microscopy
… soft viscoelstic domains. With the mathematical model it was demonstrated that the phase contrast between viscoelastic materials and silicon can be used to predict the local viscosity and elastic modulus. Experiments were done on a surface with a silicon domain which is hard and elastic and …
-
Exploring the Nonlinear Dynamics of Tapping Mode Atomic Force Microscopy with Capillary Layer Interactions
Central to tapping mode atomic force microscopy is an oscillating cantilever whose tip interacts with a sample surface. The tip-surface interactions are strongly nonlinear, rapidly changing, and hysteretic. We explore numerically a lumped-mass model that includes attractive, adhesive, and repulsive …
-
Quantitative Prediction of Tip-Sample Repulsive Forces and Sample Deformation in Tapping-Mode Frequency and Force Modulation Atomic Force Microscopy
… graphically and through a multiple regression model so that the user can predict the tip penetration and maximum repulsive force with knowledge of the maximum attractive force and steepness of the repulsive regime in the tip-sample interaction force curve. The prediction model is shown to be …
-
Molecular-Level Studies of Nanopatterned Biomolecules with Atomic Force Microscopy
… The AFM instrument has three general operational modes, which are contact, non-contact and tapping-mode, that can be used to examine materials at the atomic level. Single-molecular details of biological molecules and other soft organic materials can be captured with minimal denaturation in either …
-
In-situ analysis of polymer film coats using AFM and thermal probe methods
… However the novel technique of heated tip tapping mode was employed, which was able to resolve separate domains of the polymer blends, which appeared as nanophases. Heated tip tapping mode was further employed to determine changes in the surface morphology of film coated minitablets which …
-
Investigating the Role of Mechanical Properties in Biological Systems
… using AFM-based techniques. Specifically, tapping mode AFM-based techniques were used to investigate the influence of lipid composition and temperature fluctuations on the physicomechanical properties of supported lipid bilayers. Topographic images were produced by tapping mode AFM, while …
-
Nanotechnology: a systems and control approach
… scale. The AFM operating in the most common tapping-mode has a highly complex dynamics due to the nonlinear tip-sample interaction forces. A systems approach is proposed to analyze the tapping-mode dynamics. The systems perspective is further exploited to develop analytical tools for modeling …
-
Atomic force microscopy study of the metal surface during a palladium- catalyzed hydrogenation membrane reaction
… at atmospheric conditions and in real time. Tapping-mode AFM can examine chemical and physical phenomena on surfaces in addition to topography. The work here describes using phase-angle information from tapping-mode AFM to observe liquid/solid interfaces in real time during the hydrogenation …
-
Studying liquid-phase heterogeneous catalysis using the atomic force microscope
… under or near actual reaction conditions. Tapping-mode AFM was explored here because it expands AFM beyond the usual topographic information toward speciation and other more subtle surface information. This work describes using phase-angle data from tapping-mode AFM to follow the …
-
Optical Lever Measurement Accuracy for Off-Resonance Atomic Force Microscopy
… interaction forces during intermittent contact mode AFM can alter this response profile. Standard tapping-mode operation at the fundamental frequency is observed to be robust to changes in effective stiffness, maintaining accurate measurements for all laser spot positions considered. A nominal …
-
Ultra small biomorphic cantilevers for high-speed atomic force microscopy
… which operates in amplitude modulation mode, leverages small cantilevers characterized by high resonance frequencies. It offers the unique capability of real-time visualization of molecular processes. However, due to the relatively substantial interaction forces involved, HS-AFM in …
-
Wetting behavior and surface potential characteristics of human hair
… the current characterization of human hair. Tapping mode atomic force microscopy (AFM) is used to generate surface height maps of hair, which are then compared to maps generated using contact mode AFM. Contact mode has been used in the past and has the potential of damaging small surface …
Page 1 of 6