Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 120 for “"target coverage"”
-
A comparison of two target coverage models
… examines several models for the computation of target coverage when multiple rounds are fired at a target. Fractional kill of a fragment sensitive target by a fragmenting projectile as a function of the number of rounds fired is compared for two models. The first is a standard salvo-fire model …
-
Energy-efficient target coverage in heterogeneous wireless sensor networks
… that are deployed randomly to cover certain targets. Since targets are covered by many sensors, we create several cover sets that are active successively to save power. We introduce the Heterogeneous Connected Set Covers (HCSC) which aims to find at least one cover set that covers all the …
-
Improved Target Coverage of Spinal Metastases Through The Use of Flattening Filter Free Beams
… the cord and cauda equina. This proximity of the target to critical structures has the potential to compromise the efficacy of the radiation treatment plan in favor of reducing normal tissue dose, resulting in poor local control and tumor recurrence at follow-up. Flattening Filter Free (FFF) …
-
Multi-Robot Online Coverage Path Planning: Enhanced Collaboration and Task Allocation Strategies for Area and Target Coverage Tasks
<p>Multi-robot online coverage path planning is essential for applications such as environmental monitoring, search and rescue, and urban surveillance. However, it faces significant challenges in dynamic and unknown environments. Key issues include enhancing collaboration among multiple robots for …
-
Development of Novel Intracavitary Intensity Modulated Brachytherapy Applicators for Optimizing the Target Coverage in Gynecologic Malignancies, Monte Carlo Simulation Dosimetry
… This technique enables high radiation doses to a target with rapid dose fall-off to protect adjacent healthy organs. This dissertation aims to address some of the limitations of intracavitary GYN-BT using an intensity modulated brachytherapy (IMBT) technique and Monte Carlo (MC) simulations. …
-
A study of coverage optimized planning incorporating models of geometric uncertainties for prostate cancer
… treatment volume (PTV) margin on the treatment target. However, it is difficult to determine a near-optimal PTV margin to ensure specified target coverage with as much normal tissue protection as achievable. Coverage optimized planning (COP) avoids this problem by optimizing dose in possible …
-
An Optimization-Based Treatment Planner for Gamma Knife Radiosurgery
… the exposure time for each shot to improve the target coverage while minimizing toxicity to the surrounding tissues, and (3) fine-tune the shot configuration by adjusting shot locations, and adding or deleting shots to further improve the balance between target coverage and normal tissue …
-
Feasibility and constraints of Bragg peak FLASH proton therapy beam delivery and treatment planning
… plans achieve sufficient ultra-high dose rate coverage. However, they demonstrate inferior target coverage and increased doses to organs at risk (OARs) compared to IMPT. Chapter 4 assesses the impact of dose rate optimisation on the quality of FLASH-PT treatment plans by utilising two treatment …
-
Clinical implementation of quality-assured and optimized pencil beam scanning proton therapy for moving targets
… However, the application of proton therapy for targets undergoing respiratory motion is limited due to uncertainties in the delivered dose caused by motion and interplay effects. The assessment of the delivered dose distributions including these motion effects as well as treatment planning with …
-
Respiratory and Breath Hold Motion in Contemporary Breast Irradiation: Dosimetric Impact and Management Techniques
… can result in suboptimal plan quality, decreased target coverage, and increased dose to organs at risk. This thesis examines two sources of respiratory motion during breast radiotherapy: (1) free-breathing motion, and (2) residual motion during deep inspiration breath hold. The effect of …
-
Four-dimensional radiation therapy for thoracic carcinoma : Dosimetric evaluation using deformable image registration
… a significant challenge for radiation therapy in targeting the tumour. The use of planning margins to avoid geometrical miss of the target volume during respiration results in excessive lung tissue irradiation that limits the prescribed dose to be safely delivered and escalated for better …
-
Dosimetric investigation of image-guided radiotherapy for prostate cancer using cone-beam computed tomography
… imaging frequency on actual dose delivered to target volume and organs at risk during a course of image-guided radiotherapy for prostate cancer. 4. To compare the dosimetric effects of reduction of CTV-PTV margin with daily imaging. / Material and Methods: 59 radiotherapy centres in the United …
-
Inverse treatment planning for radiofrequency ablation
… tumors. In RFA, needles are inserted into the target with image guidance and current is passed through the needles, resulting in high temperatures and consequently target ablation. However, RFA has a high local recurrence rate caused by incomplete ablation. We therefore develop a novel …
-
Quantification and management of uncertainties in radiation therapy
… that the approach offers increased control over target coverage and organ-at-risk (OAR) doses, since in many cases target coverage or OAR dose could be improved compared to the rigid image registration approach. However, for pronounced anatomical changes, both approaches were unable to restore an …
-
An evaluation of computerised tomography (CT) based treatment planning versus digitised image planning (standard planning technique) for carcinoma of the breast, using the four field breast technique
… How do the plans differ in terms of dose coverage to the supraclavicular and axillary nodes? What is the relationship between the depth of the supraclavicular nodes and the patient separation? ii What is the relationship between the depth of the axillary nodes and the patient …
-
Validation and Implementation of Automated Planning Optimization in Utah Valley Hospital
… SRS model tailored to single-isocenter multitarget workflows was created. Seventy retrospectively selected patients were replanned using RapidPlan-generated objectives under identical beam configurations, prescriptions, and normalization criteria, followed by detailed comparison of target …
-
The Effect of Shoulder Variation On Imrt and Smartarc For Head and Neck Cancer
… isocenter alignment on the dose delivered to the target and the surrounding structures for head and neck cancer patients. Method and Materials: The frequency of shoulder shifts of various magnitudes relative to isocenter was assessed for 4 patients using image registration software. The location …
-
ESTIMATING THE INDIRECT IMPACT OF THE COVID-19 PANDEMIC ON NEONATAL MORTALITY IN NEPAL
… change in pregnancy and childbirth intervention coverage during the pandemic. We also aimed to track the neonatal mortality rate during and after the pandemic against the national targets. In addition, we aimed to visualize priority interventions and cost for scaling up to universal coverage. …
-
Robust Treatment Planning and Robustness Evaluation for Proton Therapy of Head and Neck Cancer
… by generating high conformal doses to the target volume and improved sparing of the organ at risks (OARs). Besides, robust treatment planning approaches, which account for uncertainties directly into the plan optimization process, are able to generate high quality plans robust against …
-
Patient-Specific Monte Carlo Dosimetric Evaluation of Heterogeneity effects in Tile - based Cesium-131 Permanent Intracranial Brachytherapy with Clinical Validation
… the dosimetric impact of tissue heterogeneity on target coverage and organ-at-risks (OAR) sparing using a high-fidelity MC framework with retrospective patient CT DICOM datasets of intracranial ¹³¹Cs implants. Furthermore, the theoretical applicability of the Linear Boltzmann Transport Equation …
Page 1 of 6