Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 20 for “"target delineation"”.
-
Co-Segmentation Methods for Improving Tumor Target Delineation in PET-CT Images
… provides helps radiation oncologists to better target the tumor region. However, currently most tumor delineations in radiotherapy planning are performed by manual segmentation, which consumes a lot of time and work. Most computer-aided algorithms need a knowledgeable user to locate roughly the …
-
Auto-Delineation of Oropharyngeal Clinical Target Volumes Using Deep Learning Techniques
… radiation dose to the defined treatment targets achieving more accurate target dose distribution and better sparing of normal tissues. However, producing very precise treatment plans may be ineffective if the target volumes are not defined accurately. Furthermore, there are several …
-
Thoracic Radiotherapy Treatment Planning With Cine Pet/Ct
… respiration. Treatment margins can be reduced by targeting the motion path of the tumor. The expense and complexity of 4D-CT, however, may be cost-prohibitive at some facilities. We developed an image processing technique to produce images from cine CT that contain significant motion information …
-
Determination of geometric uncertainties and their inclusion into margins for three dimensional conformal radiotherapy of the prostate
… by reducing the margin applied to the clinical target volume (CTV) to form the planning target volume (PTV). As the size of this margin has approached the magnitude of the geometric uncertainties involved in 3D CRT, determining these uncertainties for individual centres and treatment techniques …
-
Automated Segmentation of Head and Neck Cancer Using Texture Analysis with Co-registered PET/CT images
… for head and neck cancer(HNC). Accurate target delineation is essential for the success of radiation therapy. The current target definition technique - manual delineation using Computed Tomography(CT) - is subject to high observer variability. Functional imaging modalities such as …
-
Thoracic Target Volume Delineation Using Various Maximum-Intensity Projection Computed to mography Image Sets For Stereotactic Body Radiation Therapy
… because it increases the uncertainty of target position. The adoption of four-dimensional computed tomography (4D-CT) has allowed us to determine how a tumor moves with respiration for each individual patient. Using information acquired during a 4D-CT scan, we can define the target, …
-
Advancing Treatment Accuracy of Accelerated Partial Breast Irradiation
… multiple radiological imaging modalities used in target delineation during high-precision radiotherapy treatment planning. The proof of concept was demonstrated using a small version of the phantom and with co-registered helical computed tomography (CT), cone beam computed tomography (CBCT), and …
-
Advancing Radiotherapy Treatment Through Artificial Intelligence-Driven Approaches
… precise radiation doses to specific tumor target volumes while minimizing exposure to surrounding healthy tissues and organs. To achieve precision and high treatment quality, accurate target delineation, streamlined workflows, and timely follow-up are necessary. However, the current …
-
CONE-BEAM COMPUTED TOMOGRAPHY (CBCT) SEGMENTATION BY ADVERSARIAL LEARNING DOMAIN ADAPTATION
… adaptive therapy where organ segmentation and target delineation are often required. However, due to the poor image quality, low soft tissue contrast, as well as the difficulty in acquiring segmentation labels on CBCT images, developing effective segmentation methods on CBCT has been a …
-
Machine learning enables the use of spectroscopic MRI to guide radiation therapy in patients with glioblastoma
… threshold-based techniques to be used for target delineation. Third, we create a novel unsupervised learning framework to perform accelerated spectral quantitation, reducing the computational time and power needed to utilize sMRI. Finally, we develop a web-based software framework that …
-
4D Study of Thoracic Cancer Radiation Treatment
… between each voxel in the reference image to the target image for registration. With OFM, we were able to develop and validate an automated method for intrathoracic motion estimation from breath-hold and 4-D computed tomography imaging; demonstrate the path integration of a four-dimensional dose …
-
Neuartige Zielvolumendefinition für die Strahlentherapie des Glioblastoma multiforme
Background: For target delineation in Glioblastoma there are currently two major consensus guidelines being used, the one of the European Organisation for Research and Treatment of Cancer (EORTC) and the one of the Radiation Therapy Oncology Group (RTOG). The resulting target volumes are often …
-
Quantification of Respiratory Motion in Positron Emission Tomography for Precise Radiation Treatment of Lung Cancer
… significant challenge for RT is to accurately target the lesion volume while avoiding the irradiation of surrounding healthy tissue. Currently at the Juravinski Cancer Centre (JCC), treatment plans for lung cancer patients are completed using fluorodeoxyglucose positron emission tomography …
-
Development and Characterization of a Liposome Imaging Agent
… as its pharmacokinetics, biodistribution, tumor targeting and imaging performance. Emphasis was placed on the in vivo CT-based quantification of liposome accumulation and clearance from healthy and tumor tissues in a VX2 carcinoma rabbit model, gaining insight not only on the spatial but also the …
-
On Tumor Motion, Delineation Strategies, and Respiratory Induced Density Variations Associated with Stereotactic Lung Radiotherapy
… an investigation into the range dependence of target delineation strategies for stereotactic lung radiotherapy. The purpose of this study was to evaluate alternative target segmentation strategies with respect to the 10 phase “gold standard” benchmark. In clinical scenarios for lung tumor …
-
Validation and clinical implementation of an MRI-only prostate cancer radiotherapy workflow
… bias was found to displace the estimated target position by up to 3 mm, compared to the clinical baseline. The delineated prostate volume was, on average, 18% smaller in the MRI-only delineation procedure than in dual-modality delineation. If this difference is not accounted for, a …
-
Quantitative techniques for permanent breast seed implant brachytherapy
… of operator dependence. Challenges relating to target visualization uncertainties and the reliance on free-hand 2D ultrasound (US) guidance potentially inhibit adoption of the technique. This work aims to evaluate the current PBSI procedure to identify uncertainties and potential sources of …
-
Consensus Segmentation for Positron Emission Tomography: Development and Applications in Radiation Therapy
… of this radiotracer are used for the staging, delineation and assessment of treatment response of patients undergoing chemotherapy or radiation therapy. While PET offers the ability to provide functional information, the imaging quality of PET is adversely affected by its lower spatial …