  1. Seawinds Radiometer Brightness Temperature Calibration And Validation

    … the ocean microwave emissions (brightness temperature, Tb) simultaneously with the backscattered power. When SeaWinds on ADEOS was launched, this same algorithm was applied, but the results were anomalous. The initial SRad brightness temperatures exhibited significant, unexpected, …

    ucf Repository record for Seawinds Radiometer Brightness Temperature Calibration And Validation (opens in a new tab)

  2. Brightness Temperature Calibration Of Sac-d/aquarius Microwave Radiometer (mwr)

    … dissertation focuses on the overall radiometric calibration of MWR instrument. Which means establishing a transfer function that relates the instrument output to the antenna brightness temperature (Tb). To achieve this goal, the dissertation describes a microwave radiative transfer model of the …

    ucf Repository record for Brightness Temperature Calibration Of Sac-d/aquarius Microwave Radiometer (mwr) (opens in a new tab)

  3. Temperature Calibration and Electrode Preparation for Use in the Study of Ionic Conductivity of AgBr Thin Films

    … measurements are done as a function of temperature for each of the thin films. A series of temperature calibration experiments for the sample holder were done to enable the determination of the temperature of the sample during ionic conductivity measurements. The calibration experiments …

    marquette Repository record for Temperature Calibration and Electrode Preparation for Use in the Study of Ionic Conductivity of AgBr Thin Films (opens in a new tab)

  4. SOLID PHASE EPITAXY IN AMORPHOUS SILICON: KINETICS ON MILLISECOND TIMESCALE AND USE AS TEMPERATURE CALIBRATION FOR LSA

    … KINETICS ON MILLISECOND TIMESCALE AND USE AS TEMPERATURE CALIBRATION FOR LSA Min Wu Abstract The kinetics and mechanism for solid phase epitaxy (SPE) in has been widely studied due to its critical use in the semiconductor industry. Extensive studies have established the kinetics of this …

    cornell Repository record for SOLID PHASE EPITAXY IN AMORPHOUS SILICON: KINETICS ON MILLISECOND TIMESCALE AND USE AS TEMPERATURE CALIBRATION FOR LSA (opens in a new tab)

  5. Image Processing to enable Transient Temperature Profiling during Laser Spike Annealing

    … rapid thermal annealing technique, which utilize temperature gradients to extract temperature-dependent material properties. This method reduces the need for numerous samples and saves time. Accurate temperature calibration is crucial for lg-LSA's success. Existing methods, such as thermocouples, …

    cornell Repository record for Image Processing to enable Transient Temperature Profiling during Laser Spike Annealing (opens in a new tab)

  6. Design and security of analog and mixed-signal circuits with innovations in temperature sensing for power/thermal Management, Trojan detection in analog filters, and optimization for programmable current mirrors

    This dissertation presents a novel CMOS-based temperature sensor aiming to improve on-chip power/ thermal management by monitoring potential hotspot formation across different locations on a semiconductor die. The sensor is designed with two correlated output voltages, which embeds temperature …

    iastate Repository record for Design and security of analog and mixed-signal circuits with innovations in temperature sensing for power/thermal Management, Trojan detection in analog filters, and optimization for programmable current mirrors (opens in a new tab)

  7. THE CORAL CLADOCORA CAESPITOSA AS A HIGH RESOLUTION PALAEOCLIMATE ARCHIVE

    … method to reconstruct seawater growth temperatures for palaeoenvironmental studies. In this work the temperate, colonial, Mediterranean scleractinian coral Cladocora caespitosa was investigated. First modern Adriatic corals from Mljet (Croatia) where growth temperatures were known were …

    east-anglia Download PDF for THE CORAL CLADOCORA CAESPITOSA AS A HIGH RESOLUTION PALAEOCLIMATE ARCHIVE (opens in a new tab)

  8. Temperature mapping of particles during aseptic processing via magnetic resonance imaging

    … Magnetic Resonance Imaging (MRI) techniques for temperature measurement of particles undergoing aseptic processing were studied. A variable flip angle gradient echo sequence was initially tested. With this sequence T1 maps were obtained from two images acquired in sequence with a total imaging …

    uiuc Repository record for Temperature mapping of particles during aseptic processing via magnetic resonance imaging (opens in a new tab)

  9. Sapphire Based Fiber-Optic Sensing for Extreme High Temperatures

    Temperature sensing is one of the most common and needed sensing technique, especially in harsh environment like a coal gasifier or an airplane engine. Single crystal sapphire has been studied in the last two decades as a candidate for harsh environment sensing task, due to its excellent mechanical …

    vt Repository record for Sapphire Based Fiber-Optic Sensing for Extreme High Temperatures (opens in a new tab)

  10. High sensitivity MEMS sensors for air flow measurement

    … ultra-high sensitivity (> 440 fF/kPa) and low temperature dependence, aiming to eliminate the need for factory temperature calibration for pressure and gas flow measurement applications. The MEMS gas flow sensor based on pMUT technology demonstrates the feasibility of ultrasound technology for …

    aalto Repository record for High sensitivity MEMS sensors for air flow measurement (opens in a new tab)

  11. Late Medieval Climate Changes in the Tropical Atlantic and Interannual Variability Documented in Northeastern Caribbean Corals

    Tropical sea surface temperature (SST) has been implicated as a driver of climate changes during the Medieval Climate Anomaly (MCA, 950-1300 CE) but little data exist from the tropical oceans for this time period. I collected multiple Diploria strigosa coral colonies from Anegada, British Virgin …

    maryland Repository record for Late Medieval Climate Changes in the Tropical Atlantic and Interannual Variability Documented in Northeastern Caribbean Corals (opens in a new tab)

  12. oai:macau.uni-kiel.de:diss_mods_00002079

    A new approach for a solid delta44/40Ca temperature calibration of the polar to subpolar planktonic foraminifera N. pachyderma (sin.) is presented, based on a broad sample pool comprising North and South Atlantic genotyped net catches and Nordic Seas core top sample material. With this new …

    cau-kiel Repository record for oai:macau.uni-kiel.de:diss_mods_00002079 (opens in a new tab)

  13. Planar Ion Probe for Low-Latitude Ionosphere/Thermosphere Enhancements in Density Cubesat Mission

    … for a dual CubeSat mission to study equatorial temperature and wind anomaly in the Earth’s ionosphere. The Langmuir probe instrument developed is of a planar geometry and fix biased in the ion saturation region, i.e. negative w.r.t. spacecraft chassis. Operating the Langmuir probe in the ion …

    embry-riddle Repository record for Planar Ion Probe for Low-Latitude Ionosphere/Thermosphere Enhancements in Density Cubesat Mission (opens in a new tab)

  14. Phosphor Thermometry on Surfaces - A Study of its Methodology and its Practical Applications

    … an optical measurement technique for remote temperature sensing. Its working principle is based on the temperature-sensitive emission characteristics of certain ceramic substances termed thermographic phosphors. These inorganic materials can either be coated on objects for surface thermometry …

    lund Repository record for Phosphor Thermometry on Surfaces - A Study of its Methodology and its Practical Applications (opens in a new tab) Download PDF for Phosphor Thermometry on Surfaces - A Study of its Methodology and its Practical Applications (opens in a new tab)

  15. Analysis of a High-Temperature Spectroscopic Gas Cell Design

    … spectroscopy systems. While many lower temperature lines are well characterized, the higher temperature and pressure lines found in studies of combustion products rely on theoretical scaling. High-temperature calibration devices are therefore desired to allow experimental validation of …

    ut-knoxville Repository record for Analysis of a High-Temperature Spectroscopic Gas Cell Design (opens in a new tab)

  16. Raman-based study of micro/nanoscale structure and thermal transport

    … significant drawback of this method is that both temperature and power dependent Raman study should be done to extract the thermal conductivity of the sample. The laser absorption is also subject to very large errors induced by unknown sample-to-sample optical property variation. In addition, for …

    iastate Repository record for Raman-based study of micro/nanoscale structure and thermal transport (opens in a new tab)

  17. FIBRE OPTIC COUPLED, INFRARED THERMOMETERS FOR PROCESSES INCURRING HARSH CONDITIONS

    … in harsh conditions that would affect contact temperature measurements deleteriously. The IRTs have been configured without photodiode cooling and signal chopping but achieved low minimum measurable temperatures, fast responses and good sensitivities. IRTs were configured with mid-wave infrared …

    whiterose Download PDF for FIBRE OPTIC COUPLED, INFRARED THERMOMETERS FOR PROCESSES INCURRING HARSH CONDITIONS (opens in a new tab)

  18. Modular GC: A Fully Integrated Micro Gas Chromatography System

    … Outlet µGC system. We have designed a novel auto-calibration method for temperature calibration of the microfabricated devices which does not require changing the electronic circuitry or reprogramming the device. The vacuum outlet µGC setup is tested with various mixture of analytes. For these …

    vt Repository record for Modular GC: A Fully Integrated Micro Gas Chromatography System (opens in a new tab)

  19. Design and implementation of cost-efficient analog-to-digital conversion circuits for sensor applications

    … research activity is a monitoring smart temperature sensor based on frequency domain analog-to-digital conversion. The proposed analog calibration method and the ratio-metric conversion with oscillators avoid the cost of a two-point temperature calibration and result in satisfying …

    freiburg-diss Repository record for Design and implementation of cost-efficient analog-to-digital conversion circuits for sensor applications (opens in a new tab)

  20. Clumped isotopes in planktonic foraminifera: application in a multiproxy North Atlantic study

    … reference frame. A foraminifera clumped isotope temperature calibration is derived through measurement of 25 Atlantic core top samples: [delta]47=0.0314 (±0.0027)×106/T2+0.3171 (±0.0332) The calibration shows good agreement with previous studies. However, measurement uncertainty remains too large …

    east-anglia Repository record for Clumped isotopes in planktonic foraminifera: application in a multiproxy North Atlantic study (opens in a new tab) Download PDF for Clumped isotopes in planktonic foraminifera: application in a multiproxy North Atlantic study (opens in a new tab)

Page 1 of 3