Showing 1 to 20 of 54 for “"temperature probe"”.
-
Total Temperature Probe Performance for Subsonic Flows using Mixed Fidelity Modeling
An accurate measurement of total temperature in turbomachinery flows remains critical for component life models and cycle performance optimization. While many techniques exist to measure these flows, immersed thermocouple based probes remain highly desirable due to well established practices for …
-
Investigations of a single point temperature probe for measurement of atmospheric turbulence
Gradients in the index of refraction caused by temperature fluctuations create optical turbulence. This optical turbulence greatly degrades the performance of imaging and laser systems operating in the atmosphere. There are several methods of measuring optical turbulence in the atmosphere, but few …
-
Impact of Total Temperature Probe of Geometry on Sensor Flow and Heat Transfer
The measurement of temperature in hot gases plays an important role in many engineering applications, such as the efficiency and performance of an engine. As such, understanding the accuracy of these temperature measurements is also important. One of the common ways in which temperature is measured …
-
CHARACTERIZATION OF HEAT TRANSFER COEFFICIENT UNCERTAINTY IN SUPPORT OF HIGH TEMPERATURE PROBE MEASUREMENT TECHNOLOGY
… and research devices that operate in high temperature environments. Measurement technology must keep up with the demand of these environments.</p> <p>The objective of this work is to provide a correlation between the heat transfer coefficient (and Nusselt Number) and the flow Reynolds …
-
Characterization of Convective Heat Transfer Coefficients of a Self-Aspirated Hot Gas Temperature Probe
… for various surfaces of an aspirated total temperature probe exposed to high temperature flow. The experiment discharged thermally stabilized dry air through large scale models of the probe surfaces in a blow-down wind tunnel and a direct connect facility. The model contained electrically …
-
Development of a temperature probe radiation shield which is heated by the combustion of gases
<p>Accurate measurement of high gas temperatures is essential to the safe and efficient operation of steam generating units. With the trend toward using greater temperatures in combustion technology, instruments which can be used to obtain a more accurate temperature have become an important tool …
-
Perioperative targeted temperature management of severely burned patients by means of an oesophageal temperature probe
… tube (EHT) can improve perioperative body temperatures in severely burned patients. The aim of this study was to investigate the intraoperative warming effect of oesophageal heat transfer in severe burn patients. Methods: Single-centre retrospective study performed at the Burns Centre of …
-
The Development of a Temperature Probe and Temperature Survey of the Interaction of an Oblique Shock Wave and a Turbulant Boundary Layer
… investigation was to develop a miniature air temperature probe and to measure temperatures in the interaction region of an oblique shock wave and a turbulent boundary layer.
-
Nesting Cavity Temperature Impacts Nesting Choice and Development of the Alfalfa Leafcutting Bee (Megachile rotundata)
… and Bosch, 2011). Nesting boxes can reach temperatures between 35˚C-48˚C (see Chapter 2). These temperatures can cause damage to multiple stages of development, including death (Barthel et al. 2002, Rossie et al. 2010). To date, it is unclear how cavity temperature varies across the box. …
-
An Experimental Conduction Error Calibration Procedure for Cooled Total Temperature Probes
The accurate measurement of total temperature in engine diagnostics is a challenging task which is subject to several sources of error. Conduction error is predominant among these sources since total temperature sensors are embedded into a cooled strut for measurement. This study seeks to …
-
Aspects of Linear and Nonlinear Transport in Mesoscopic Systems
… we demonstrate that electric current noise in a temperature probe can provide a measure of an "effective" local temperature in a non-equilibrium system. We show that this electrical measurement is consistent with a thermal measurement of the temperature probe, within the limit of the validity of …
-
An investigation into the soot production processes in a gas turbine engine.
… turbine combustor. The goal was to obtain axial temperature profiles an! soot size distributions inside an Allison T63-A-5A combustor. The present temperature probe and gas sampling apparatus were able to acquire data. Results from these initial tests suggested some preliminary conclusions. First …
-
True phoenix: Static source position error corrections for the pitot-static systems on an F-16 falcon
… the production F-16B noseboom-mounted air data probes to collect data for both total and static pressure systems. A total air temperature probe was mounted on the underside of the left forebody strake and provided the pacer air data computer with an air temperature measurement. The pacer …
-
ADDITIVELY MANUFACTURED INSTRUMENTATION FOR ENHANCED FLOWFIELD MEASUREMENT IN A TRANSONIC AXIAL COMPRESSOR
… instrumentation for stagnation pressure and temperature measurement in the Naval Postgraduate School's Transonic Compressor Rig (TCR), aiming to match the performance of existing instruments with application-specific design. A method was also developed for integrating Laser Doppler Anemometry …
-
Construction of a Shielded Thermal Hall Measurement Device
… included the addition of coaxial cables to a low-temperature probe. A copper sample puck was machined and encases the sample, thermometers, and sample heater, to reduce mechanical stress and shield from electromagnetic radiation. SrTiO3 wafers were fabricated into capacitive thermometers by …
-
Universal Control in 1e-2n Spin System Utilizing Anisotropic Hyperfine Interactions
… controls on the spin system. A customized low temperature probe was designed and built to have three features necessary for the experiments. First, it is possible to orient the sample, thus to change the spin Hamiltonian of the system, in situ. Second, the combined system is able to perform ESR …
-
Heat-transfer-based Biomedical Devices: Synergistic Numerical Simulations and Experimentation
… a non-invasive means of measuring the body core temperature under both steady state and transient circumstances. A realistic application of such a probe is the monitoring of the temperature of a patient undergoing surgery. The investigation of the novel temperature probe involved the interaction …
-
CFD Simulation of the Thermal Performance of a Parallel Counter-Parallel Flow Heat Exchanger for the Treatment of Hypothermia
… data. In the experimental set-up, the outlet temperature was evaluated using a center-point temperature probe. The current CFD study evaluated the outlets in terms of mean bulk temperature to better characterize the thermodynamic average with respect to fluid flow. Despite this difference, the …
-
Development of a medium independent flow measurement technique based on oscillatory thermal excitation
… flow sensor that includes at least three temperature sensors (germanium thermistors) and a heater. Two thermistors are respectively placed up- and downstream with respect to a central thermistor, which is closely surrounded by the heater. The flow signal corresponds to the DC temperature …