Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 7 of 7 for “"terminal protection"”

  1. Measurement of Dielectric Properties of Ferroelectric and Electrostrictive Materials : Error Analysis and High Voltage Terminal Protection

    … a reliable and dependable high voltage terminal protection device was designed and implemented successfully in the EE department's dielectric measurement system at SDSU. The fixtures and cabling of the additional high voltage protection circuitry can affect the measurement results by …

    sdstate Repository record for Measurement of Dielectric Properties of Ferroelectric and Electrostrictive Materials : Error Analysis and High Voltage Terminal Protection (opens in a new tab)

  2. The preclinical investigations of inflammation and excitotoxicity in mouse models of Parkinson's disease

    … increase in dopamine levels and striatal terminal protection. This nigral protective effect of activin A was replicated in the 6-OHDA model of PD. Animals receiving activin A also had lower numbers of astrocytes and microglia following MPTP and LPS, suggesting that activin A’s …

    unsw Repository record for The preclinical investigations of inflammation and excitotoxicity in mouse models of Parkinson's disease (opens in a new tab)

  3. Part I. The Rational Design, Synthesis and Evaluation of Second Generation Class II HMG-CoA Reductase Inhibitors Part II. Studies Directed Toward the On-Resin Preparation of C-terminal Modified and Cyclic Peptides

    … contribute new methods for the preparation of C-terminal modified and cyclic peptides on the solid-phase using the backbone amide linker (BAL) approach. To this end, an improved one-step preparation of 1,1-dimethylallyl esters (DMA) was developed for the C-terminal protection of amino acids. …

    purdue-thes Repository record for Part I. The Rational Design, Synthesis and Evaluation of Second Generation Class II HMG-CoA Reductase Inhibitors Part II. Studies Directed Toward the On-Resin Preparation of C-terminal Modified and Cyclic Peptides (opens in a new tab)

  4. One-terminal traveling wave-based protection for HVAC and HVDC transmission lines

    This work proposes developing one-terminal traveling wave-based transmission line protection methods for HVAC (High Voltage Alternating Current) and HVDC (High Voltage Direct Current) systems. It considers the effect of the sampling frequency on the protection, which until now has not been …

    brazil-ufrn Repository record for One-terminal traveling wave-based protection for HVAC and HVDC transmission lines (opens in a new tab)

  5. Ověření vývodové ochrany ABB REF615 s využitím experimentálního modelu distribuční soustavy 22 kV

    Cílem této bakalářské práce je popsat, nastavit a ověřit funkce digitální ochrany ABB REF615. Dále je práce zaměřena na ochranu z hlediska jejích ochranných funkcí a hardwarové konfigurace. Práce vás také seznámí s parametry experimentálního modelu distribuční soustavy 22 kV. Tento model byl použit …

    brno-tech Repository record for Ověření vývodové ochrany ABB REF615 s využitím experimentálního modelu distribuční soustavy 22 kV (opens in a new tab)

  6. Terminál pro řízení a chránění vývodového pole REF 542 plus

    Hlavním cílem mé bakalářské práce je testování multifunkčního terminálu pro řízení a ochranu vývodového pole REF 542plus od firmy ABB. Testování tohoto IED (Intelligent Electronic Device) zařízení vyžaduje dokonalé pochopení jeho funkční struktury, vlastní konfigurace, dostupných nástrojů a …

    brno-tech Repository record for Terminál pro řízení a chránění vývodového pole REF 542 plus (opens in a new tab)

  7. Fault Identification of UPFC-Compensated Transmission Lines in Complex Microgrids Using an Intelligent Relaying Scheme Based on Discrete Wavelet Transform and ANN Classifier

    … injections, may change at any time; hence, the protection task is complicated during fault occurrences. The fault data is highly nonlinear and nonstationary, making a conventional distance relay dysfunctional. To fix this, many researchers have used signal processing and soft computing …

    calgary Repository record for Fault Identification of UPFC-Compensated Transmission Lines in Complex Microgrids Using an Intelligent Relaying Scheme Based on Discrete Wavelet Transform and ANN Classifier (opens in a new tab)