Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 19 of 19 for “"the bolometer"”.

  1. Calibration of a germanium bolometer for use in cold-background radiometric testing

    <p>A germanium bolometer has been obtained and evaluated for possible use in radiometric testing. The instrument and test procedures are described, and results are presented which detail the bolometer's response to a variety of operating conditions. Suggested improvements to the bolometer and the …

    ut-knoxville Repository record for Calibration of a germanium bolometer for use in cold-background radiometric testing (opens in a new tab)

  2. Characterization, Optimization, and Operation of TES Bolometers for EBEX

    The cosmic microwave background (CMB) radiation holds a wealth of information about the evolution of the universe. In particular, measurement of the B-mode polarization pattern of the CMB is a direct probe of the physics of inflation. The E and B Experiment (EBEX) was a balloon-borne telescope …

    umn Repository record for Characterization, Optimization, and Operation of TES Bolometers for EBEX (opens in a new tab)

  3. Cold-Electron Bolometers

    This thesis concerns the fabrication of Cold-Electron Bolometers (CEBs) with shadow angle evaporation technique, suitable for measuring the Cosmic Microwave Background Radiation as a part of the BOOMERanG project. We have studied two possible improvements of the absorber. Firstly, we have decreased …

    chalmers Repository record for Cold-Electron Bolometers (opens in a new tab)

  4. Infrared thermography for test machine control and material characterisation

    The aim of the PhD is to develop Infrared thermography (IRT) so that it can be used to detect and assess damage growth in metallic and composite materials. A key component is to demonstrate that cheaper and more robust microbolometers could be used to replace the expensive photon detectors that are …

    soton Download PDF for Infrared thermography for test machine control and material characterisation (opens in a new tab)

  5. Sensitivity of the CUPID Experiment to Bragg-Primakoff Conversion of Solar Axions and ALPs

    The author reports in this dissertation on the application of a technique to use bolometer detector arrays, such as those of the CUORE experiment and its proposed upgrade CUPID, to search for 14.4 keV Solar axions arising from an M1 nuclear transition of thermally excited 57Fe in the Solar core. …

    south-carolina Repository record for Sensitivity of the CUPID Experiment to Bragg-Primakoff Conversion of Solar Axions and ALPs (opens in a new tab)

  6. Room Temperature VOx Air-Bridge Bolometer integrated with Metal-Insulator-Metal Resonant Absorbers

    Spectrally-selective un-cooled micro-bolometers have many military and industrial applications for infrared sensing and imaging, e.g. target acquisition and chemical analysis. In this work, a micro-bolometer was fabricated with integrated wavelength-selective absorber based on subwavelength …

    ucf Repository record for Room Temperature VOx Air-Bridge Bolometer integrated with Metal-Insulator-Metal Resonant Absorbers (opens in a new tab)

  7. Antenna-coupled Infrared Focal Plane Array

    … investigated, consisting of antenna-coupled microbolometer fabricated using electron-beam lithography. Four different antenna designs were experimentally demonstrated at 10-micron wavelength: dipole, bowtie, square-spiral, and log-periodic. The main differences between these antenna types were …

    ucf Repository record for Antenna-coupled Infrared Focal Plane Array (opens in a new tab)

  8. An Examination of the Far Infrared Spectrum of Hydrogen Fluoride

    <p>Introduction: The absorption or emission of electromagnetic radiation from 15 μ to 1000 μ is caused by energy changes in the rotations or the skeletal vibrations of molecules. This wavelength range is known as the far infrared spectral region and has in recent years become the object of …

    utk-theses Repository record for An Examination of the Far Infrared Spectrum of Hydrogen Fluoride (opens in a new tab)

  9. Optical Simulations and Characterisations of Antenna Integrated YBCO THz Detectors

    … quasi-optical terahertz (0.1 − 10THz) detectors the beam pattern of both the detector and the transmitter antennas have to be optically matched. For this purpose a quasi-optical waveguide has to be designed to couple the RF power from the source antenna to the detector. This can be done using …

    chalmers Repository record for Optical Simulations and Characterisations of Antenna Integrated YBCO THz Detectors (opens in a new tab)

  10. INFRARED SENSORS USING SILICON MICROSTRUCTURES

    Interest in being able to see in the dark has spurred the exploration of infrared imaging systems. There are basically two groups of detectors: photon detectors and thermal detectors. The high costs of cooling apparatus and infrared ( lR ) sensitive materials restrict the wide application of the …

    nus Repository record for INFRARED SENSORS USING SILICON MICROSTRUCTURES (opens in a new tab) Download file for INFRARED SENSORS USING SILICON MICROSTRUCTURES (opens in a new tab)

  11. Group IV Mid-infrared waveguide-based bolometers

    … operate at any MIR wavelengths are required. As the MIR integrated detectors developed so far are limited by either operation wavelength range or wafer scale fabrication, thermal detectors may be the best options for low-speed applications requiring broadband detection, such as sensing. This …

    soton Download PDF for Group IV Mid-infrared waveguide-based bolometers (opens in a new tab)

  12. Electromagnetic and Quasi-Optical Analysis of Cavity Coupled Bolometers for Far-Infrared and Terahertz Receivers

    The primary concern of this thesis is the development of theoretical and computational techniques for the modelling of cavity coupled bolometric detectors for future millimetre wave and terahertz astronomical receivers. Hypersensitive bolometer based receivers will be required to answer current …

    maynooth Download PDF for Electromagnetic and Quasi-Optical Analysis of Cavity Coupled Bolometers for Far-Infrared and Terahertz Receivers (opens in a new tab)

  13. The microwave rotational spectrum of methane in the ground vibronic state

    The microwave rotational spectrum of ground state methane has been observed for the first time. Seven ΔJ=0 Q-branch transitions have been observed between 7.8 and 20 GHz with peak absorption coefficients < 6 x 10⁻¹¹ cm⁻¹: these transitions are the weakest ever observed with a Stark-modulated …

    ubc Repository record for The microwave rotational spectrum of methane in the ground vibronic state (opens in a new tab) Download PDF for The microwave rotational spectrum of methane in the ground vibronic state (opens in a new tab)

  14. Transmission Lines For Ir Signal Routing

    In this dissertation, the design, fabrication, and characterization of coplanar striplines, vias, and microstrip lines is investigated, from the point of view of developing interconnections for antenna-coupled infrared detectors operating in the 8- to 12-micron wavelength range. To our knowledge, …

    ucf Repository record for Transmission Lines For Ir Signal Routing (opens in a new tab)

  15. Microwave-coupled superconducting devices for sensing and quantum information processing

    … and devices have unique properties that make them interesting from both theoretical and practical perspective. In a superconductor cooled below its critical temperature, electrons bound in Cooper pairs have the ability to carry current without dissipation. A structure where the Cooper pairs …

    aalto Repository record for Microwave-coupled superconducting devices for sensing and quantum information processing (opens in a new tab)

  16. A THz focal plane imaging array using metamaterial-inspired bolometer and wafer-level integrated focusing elements

    There is substantial interest in terahertz (THz) for applications in communications, sensing, spectroscopy, imaging, and security. Existing THz systems are built using quasi-optical setups. To reduce cost and make THz integrated circuits a reality, approaches to wafer level integration of …

    msu

  17. Electronic, thermoelectric and optical properties of vanadium oxides: VO2, V2O3 and V2O5

    … electrons in vanadium oxides are responsible for their extreme sensitivity to external stimuli such as pressure, temperature or doping. As a result, several vanadium oxides undergo insulator-to-metal phase transition (IMT) accompanied by structural change. Unlike vanadium pentoxide (V_3O_3), …

    njit Repository record for Electronic, thermoelectric and optical properties of vanadium oxides: VO2, V2O3 and V2O5 (opens in a new tab)

  18. Experimentální měření s termovizní kamerou

    Tato práce je zaměřená na vlastnosti a princip měření termovizních kamer. V první části práce je seznámení se základními pojmy a fyzikálními zákony, na jejichž principu je založeno fungování termovizní kamery. V druhé části jsou popsány funkce detektorů infračerveného záření a charakter výstupních …

    brno-tech Repository record for Experimentální měření s termovizní kamerou (opens in a new tab)

  19. Characterisation of Silicon Photomultipliers for the detection of Near Ultraviolet and Visible light

    … applications. It is possible to nd many of them in High{Energy Physics, Astrophysics and Astroparticle Physics experiments and in the PET or SPECT medical techniques. Two different types of light detectors are usually used: thermal detectors and photoelectric effect based detectors. Among …

    trento Repository record for Characterisation of Silicon Photomultipliers for the detection of Near Ultraviolet and Visible light (opens in a new tab)