Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 24 for “"the shear reinforcement"”
-
Influence of bond and anchorage conditions of the shear reinforcement on the punching strength of RC slabs
Reinforced concrete flat slabs constitute one of the most common and efficient modern construction methods. The design of such structural system might be governed by a brittle failure in the vicinity of the slab-column connection associated to punching shear. The arrangement of transverse …
-
Nonlinear Finite Element Analysis of Reinforced Concrete Slab-Column Connections with Headed Stud/Bolt Shear Reinforcement Subjected to Punching Shear
… have been conducted by various researchers on the punching behaviour of reinforced concrete flat slabs supported on columns with headed stud/bolt shear reinforcement, there are still many parameters which have not been adequately studied in the laboratory due to cost or time constraints. As a …
-
Shear strength of prestressed concrete t-beams with welded wire fabric as shear reinforcement
In thin webbed prestressed concrete T-beams, the placement of conventional stirrups is difficult and time consuming. Welded wire fabric appears to provide a relatively economical alternative. In this study, the shear strength of prestressed T-beams reinforced with welded wire fabric as shear …
-
Torsion, shear and bending in reinforced concrete beams.
… ratio varying from zero to 1.86 are reported. The strength of the rectangular reinforced concrete beams, all of which fail due to direct shear and torsion, agree favourably with the tensile strength of concrete determined from indirect tension tests. Initial cracks occurred in all the beams at …
-
Punching shear behaviour of slab-column edge connections reinforced with fibre-reinforced polymer (FRP) composite bars
The use of fibre reinforced polymer (FRP) composites as an alternate to steel has proved to be an effective solution to the corrosion problem. However, FRP bars have low axial and transverse stiffness compared to steel bars which results in a lower shear capacity of FRP reinforced concrete (RC) …
-
Reinforced high strength concrete beams under shear
This thesis presents a discussion on the shear behaviour of reinforced high strength concrete beams and new proposed methods to predict the shear strength of reinforced normal and high strength concrete beams. High strength concrete is an advanced construction material with increased tensile …
-
Analysis of the AASHTO LFRD Horizontal Shear Strength Equation
The composite action of a bridge deck and girder is essential to the optimization of the superstructure. The transfer of forces in the deck to the girders is done across a shear interface between the two elements. The transfer occurs through the cohesion of the concrete at the interface and then …
-
Shear Capacity of Reinforced Concrete Beams at Elevated Temperatures
… are in need of rational design tools to assess the capacity of RC elements during a fire event. Previous research work focused on the flexural and axial capacities of concrete elements exposed to fire. Research addressing the shear capacity of concrete elements exposed to fire is limited in the …
-
Structural Behavior of Thin Prestressed Slab Beams in Bridges
In recent years, the need to rehabilitate or replace many short-span old bridges in the most economical way has given rise to the idea of designing a wide-and-shallow beam, so called Thin Prestressed Slab Beams (TPSBs). TPSBs are cost-effective owing to: (1) simple formwork, (2) simple …
-
Considerações sobre o projeto, cálculo e detalhamento de vigas pré-fabricadas protendidas com aderência inicial em pavimentos de edificações
… a calculation sequence to determine and detail the longitudinal and transverse reinforcement of prestesses beams with pre-composed section. All procedures are done in a way that meets all the requirements of NBR6118: 2003 and 9062:2006 Code. It shows how the checks can be made of the ultimate …
-
Shear Behaviour of Disturbed Regions in Reinforced Concrete Beams with Corrosion Damaged Shear Reinforcement
… in repairing our aging infrastructure. One of the first steps in the repair process is to quantify the strength degradation in a reinforced concrete element caused by the corrosion of reinforcing steel. An understanding of the forces involved in the load carrying mechanisms is imperative; the …
-
Impact behaviour of model prestressed concrete beams.
This research work investigates the impact behaviour of prestressed concrete beams. A total number of forty 1000 mm long model beams with a rectangular section of 44 x 65 mm were cast. The beams were divided into four with ten beams in each series. Each beam was prestressed by four 1.6 mm diameter …
-
Shear behavior of post-tensioned girder containing grouted and ungrouted ducts
This dissertation was developed to evaluate the performance of spliced post-tensioned girders with grouted and ungrouted ducts. Features such as expedited construction process and increased girder span make spliced girder systems attractive options for medium- to long-span bridges. In these …
-
Investigation of Glass Fibre Reinforced Polymer (GFRP) Bars as Internal Reinforcement for Concrete Structures
… stainless steel reinforcing bars. In spite of the availability of code provisions governing both design and certification of the GFRP bars, their use within concrete structures is currently limited to very specific applications unless some behaviour aspects are further investigated. In …
-
In-plane shake table testing of gravity load designed reinforced concrete frames with unreinforced masonry infill walls
… designing columns lap splices located above the slab in each floor or above the foundation. The lack of lap splices and the shear reinforcement was in the form of stirrups with 90-degree bends and spaced at half the depth of the frame member. As a result, the section at the base of these …
-
Computational modeling of prestress transfer, end-region cracks and shear behavior in prestressed concrete I-girders employing large-diameter strands
… prestressing strands. Recent interest in the use of larger (0.7-in. (17.8-mm) diameter) strands has been driven by potential benefits associated with reduction of the required number of strands and fabrication time, or potential increases in the workable range of prestressed concrete …
-
Μηχανισμοί αστοχίας και πειραματική διερεύνηση στοιχείων ωπλισμένου σκυροδέματος με προβλήματα διάτμησης
The use of composite materials (Fiber Reinforced Polymers - FRP) as internal and strengthening reinforcement in concrete structural members is becoming increasingly apparent. The ageing of the materials, the poorly detailed concrete members of the existing old Reinforced Concrete (RC) structures …
-
Finite Element Modelling of Reinforced Concrete Beams with Corroded Shear Reinforcement
This thesis presents a finite element (FE) modelling approach investigating the effects of corroded shear reinforcement on the capacity and behaviour of shear critical reinforced concrete (RC) beams. Shear reinforcement was modelled using a “locally smeared” approach, wherein the shear …
-
Συμπεριφορά και ενίσχυση υποωπλισμένων τοιχωμάτων από σκυρόδεμα
The present doctoral thesis refers to the experimental and numerical/analytical study of the behavior of reinforced concrete walls, characterized by the absence of the configuration of confined boundary elements and small shear reinforcement ratios, as well as to the evaluation of different …
-
Structural Performance of Concrete/Cold-formed Steel Composite Beams Supporting Composite Floor Decks
… and industrial buildings. In such construction, the wall framing is usually an assembly of cold-formed steel (CFS) studs held between CFS tracks, and the floors are normally composite concrete/LOS decks spanning between load-bearing CFS walls. Heavy hot rolled steel angles or hollow structural …
Page 1 of 2