Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 161 for “"thermistor"”.

  1. A thermistor based sensor for flow measurement in water

    … the climate of the earth. A robust, low cost thermistor based sensor suitable for use in the detection and quantification of velocity structures has been designed and developed. The flow sensor, a thermal anemometer, consists of a self-heated thermistor that is maintained at constant …

    dcu Download PDF for A thermistor based sensor for flow measurement in water (opens in a new tab)

  2. Thermistor validation and path radiance effects in ship thermal image measurements

    … distributions made with the AGA 780 compared to thermistor measurements of the ship temperatures were found to be extremely close (within one degree) at ranges of one half mile and one mile. PC-TRAN in the radiance mode was than used to compute the path radiance to the ship and compared with the …

    nps Repository record for Thermistor validation and path radiance effects in ship thermal image measurements (opens in a new tab)

  3. Determination of thermal conductivity of food materials using a bead thermistor

    … conductivity of food materials using the bead thermistor with particular reference to high temperature. Feasibility was established by examining the effects of the input parameters and the measurement error associated with them on the ability to estimate the test medium thermal conductivity …

    vt Repository record for Determination of thermal conductivity of food materials using a bead thermistor (opens in a new tab)

  4. The Influence of Environmental Factors on the Temperature of the Radiosonde Thermistor

    … <p>The heat balance equations for the thermistor and lead wires were derived and a sensitivity analysis performed to establish the significance of each heating term. The Air Force LOWTRAN 6 code was used to model the solar and infrared irradiation of the thermistor in terms of the …

    utk-theses Repository record for The Influence of Environmental Factors on the Temperature of the Radiosonde Thermistor (opens in a new tab)

  5. Computer simulation of acoustic fluctuations due to finescale temperature perturbations measured by thermistor chain.

    … by perturbing the index of refraction. A thermistor chain measures temperature from the surface to 250 m with 2 m vertical resolution and 1.85 m horizontal resolution. Thermistor data is converted to high resolution sound velocity profiles for input to an implicit finite difference …

    nps Repository record for Computer simulation of acoustic fluctuations due to finescale temperature perturbations measured by thermistor chain. (opens in a new tab)

  6. A theoretical and experimental investigation of sinusoidal and relaxation oscillations in thermistor - capacitor systems

    It is known that a thermistor displays inductive reactance and negative resistance at low frequencies when biased with a current greater than turnover current. Thus when shunted by a capacitance in this condition sustained oscillations are possible. These oscillations range from a sinusoidal small …

    ubc Repository record for A theoretical and experimental investigation of sinusoidal and relaxation oscillations in thermistor - capacitor systems (opens in a new tab) Download PDF for A theoretical and experimental investigation of sinusoidal and relaxation oscillations in thermistor - capacitor systems (opens in a new tab)

  7. Optical analysis of the ERBE scanning thermistor bolometer radiometer using the Monte Carlo method

    … employing nonscanning active cavity and scanning thermistor bolometer radiometers are orbiting the Earth to monitor its radiative emission. A numerical model has been formulated to better understand the performance of the ERBE scanning radiometer and to aid future radiometric design and …

    vt Repository record for Optical analysis of the ERBE scanning thermistor bolometer radiometer using the Monte Carlo method (opens in a new tab)

  8. A numerical study of equivalence in scanning thermistor bolometer radiometers for earth radiation budget applications

    … behavior and equivalence of the ERBE scanning thermistor bolometer radiometers. The finite-difference method is applied to the detector of the ERBE scanning radiometer to characterize its thermal and electrical dynamic behavior. The thermal analysis confirms the thermal time constant of the …

    vt Repository record for A numerical study of equivalence in scanning thermistor bolometer radiometers for earth radiation budget applications (opens in a new tab)

  9. A Thermistor Based Method for Measurement of Thermal Conductivity and Thermal Diffusivity of Moist Food Materials at High Temperatures

    … research was to assess the suitability of the thermistor based method for measuring thermal conductivity and diffusivity of moist food materials at high temperatures. Research focused on aspects of calibration, thermal contact in solid food materials, natural convection in liquid media and the …

    vt Repository record for A Thermistor Based Method for Measurement of Thermal Conductivity and Thermal Diffusivity of Moist Food Materials at High Temperatures (opens in a new tab)

  10. Investigation of temperature fluctuations near the air-sea interface

    … of wind generated waves were made. Fast response thermistors were used, one at constant absolute height and one mounted on a styrofoam float. Data were collected on an Ampex CP-100 tape recorder using FM record amplifiers and a tape speed of 1 and 7/8 ips. The data were digitized by an SDS-9300 …

    nps Repository record for Investigation of temperature fluctuations near the air-sea interface (opens in a new tab)

  11. Thermal current meter

    … as designed incorporates a temperature sensitive thermistor which is placed in the flowing water and heated. When the thermistor is allowed to cool, the varying electrical resistance is recorded, and converted to a temperature decay curve by using the known thermistor temperature-resistance …

    unsw Repository record for Thermal current meter (opens in a new tab)

  12. A transient heat probe sensor for measuring transpiration in the stem of woody plants.

    … plants. This system utilizes a single heated thermistor probe which is alternately and automatically switched between a constant (heating phase) and a variable (cooling phase) temperature mode of operation. Experiments reported here have been carried out in two distinct porous medium, packed …

    arizona-thes Repository record for A transient heat probe sensor for measuring transpiration in the stem of woody plants. (opens in a new tab)

  13. An automated probe for thermal conductivity measurements

    … The technique employs an encapsulated bead thermistor. A thermistor, more commonly used as a temperature transducer, has the inherent feature of being readily self-heated. A computer-based data acquisition and control system regulates the power supplied to the thermistor such that its …

    vt Repository record for An automated probe for thermal conductivity measurements (opens in a new tab)

  14. A Comparative Analysis of Methods for Baseline Drift Removal in Preterm Infant Respiration Signals

    … measurement of infant respiration is the use of thermistors. Accurate event detection within thermistor generated signals relies heavily upon effective noise reduction, specifically baseline drift removal. Baseline drift originates from several sensor-based factors, including thermistor placement …

    vcu Repository record for A Comparative Analysis of Methods for Baseline Drift Removal in Preterm Infant Respiration Signals (opens in a new tab)

  15. Thermal method for measuring perfusion in transplanted organs

    … periods utilizing an easily extracted thermistor probe. The continuous assessment of blood perfusion in the kidney may allow timely therapeutic maneuvers to correct any abnormality in blood flow and prevent graft thrombosis and loss; The technique involves the use of a thermistor …

    unlv Repository record for Thermal method for measuring perfusion in transplanted organs (opens in a new tab) Download PDF for Thermal method for measuring perfusion in transplanted organs (opens in a new tab)

  16. Evaluation eines suprasternalen Druck- und Geräuschsensors in der Diagnostik schlafbezogener Atmungsstörungen

    … werden dazu der nasal-orale Atemfluss mittels Thermistor und nasaler Staudruckkanüle sowie die Atemanstrengung mittels Ösophagusdruckmessung oder alternativ mittels thorako- abdominaler Induktionsplethysmographie (RIP) gemessen. Zur SBASSchweregradeinteilung werden die Anzahl der Apnoen und …

    fu-berlin Repository record for Evaluation eines suprasternalen Druck- und Geräuschsensors in der Diagnostik schlafbezogener Atmungsstörungen (opens in a new tab)

  17. Measurement of very slow flows in environmental engineering.

    … new techniques for low-cost but high-precision thermistor temperature measurements, sensor temperature matching, the generation of complex algorithms within a simple sensor and a method for obtaining two-point calibrations for non-linear sensors. Field work with these sensor strings identified …

    adelaide Repository record for Measurement of very slow flows in environmental engineering. (opens in a new tab)

  18. Optimal Control of Partial Di®erential Equations and Variational Inequalities

    … control of a two dimensional steady state thermistor problem is considered. The thermistor problem is described by a system of two nonlinear elliptic partial differential equations coupled with some boundary conditions. The boundary conditions show how the thermistor is connected to its …

    utk-theses Repository record for Optimal Control of Partial Di®erential Equations and Variational Inequalities (opens in a new tab)

  19. An Experimental Study Of The Rate Of Evaporation Of Water Droplets.

    … near its surface is directly measured using thermistors, and our measurement agrees well with the theory. Evaporation rates using the thermistor to support the droplet are measured also. Theoretical calculations of evaporation rates are discussed, and values predicted by these calculations …

    unm Repository record for An Experimental Study Of The Rate Of Evaporation Of Water Droplets. (opens in a new tab)

Page 1 of 9