Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 63 for “"thermosyphon"”.
-
A two phase closed thermosyphon.
Abstract not available.
-
Enhancement of two-phase thermosyphon heat transfer
Enhancement of the two-phase flow thermosyphon heat transfer was experimentally investigated in terms of geometry, orientation and the cooling plate temperature. The thermosyphon consists of a heated wall and a parallel cooled wall with a gap of a certain width in between. Vapor phase is generated …
-
Thermosyphon flow for cooling of compact devices
… design are developed. A two-phase thermosyphon water-cooled condenser system was built and used in an experiment and numerical investigation of the effect of heat load on chip temperature. The effect of heat load on temperature difference between chip and inlet cooling water, and …
-
Theoretical and experimental investigations of the thermosyphon
Doctor of Philosophy (Ph.D.)
-
Modeling the Transient Response of a Thermosyphon
Thermosyphon transient operation was numerically modeled. The numerical model presented in this work overcame the limitations of previous studies by including transient conduction in the vessel wall, shear stress between the rising vapor and the falling film in the thermosyphon, the influence of …
-
Two-phase closed thermosyphon with two-fluid mixtures.
… the performance of stationary two-phase closed thermosyphons with two-fluid mixtures. Three mixtures were used as the working fluids: (1) water-ethanol, (2) water-ethyleneglycol and (3) water-glycerol. The results are presented to show the effects of ratio of two fluid component, mean operating …
-
Experimental and Numerical Study of Dual-Chamber Thermosyphon
… important phenomena occurring in a dual-chamber thermosyphon. Boiling experiments were carried out using water at sub-atmospheric pressures of 9.7, 15 and 21 kPa with a three-dimensional porous boiling enhancement structure integrated in the evaporator. Sub-atmospheric pressure boiling achieved …
-
Analytical and Experimental Investigation of Thermosyphon Solar Hot Water Systems
A computer simulation of a thermosyphon system allowing load drawoff and non-ideal weather conditions has been developed. The model is restricted to the more common single cover, flat plate collector system. Using an analysis based on the present literature, this model calculates the energy …
-
VOLUMETRIC SOLAR ABSORBING FLUIDS AND THEIR APPLICATIONS IN TWO-PHASE THERMOSYPHON
A two-phase thermosyphon is a passive system utilizing gravity to transfer working fluids. The working fluids of a two-phase thermosyphon must undergo vaporization and condensation in the same system. Two-phase thermosyphons can also be used as solar collectors. Traditional solar collectors utilize …
-
Effects of Aluminum Foam on Boiling Heat Transfer for Thermosyphon Evaporator
… the utilization of open cell metal foams in thermosyphon systems has not been fully explored yet. In this study, uniform aluminum metal foam substrates with different pore densities (10 and 40 PPI), as well as composite metal foam substrates were investigated in terms of two-phase heat …
-
A study of an air convection pile, a thermosyphon permafrost protection device
… investigation was conducted on an air thermosyphon permafrost protection device called the air convection pile. Velocity and temperature profiles were measured at several vertical locations on a 10 and a 20 foot air convection pile for three different operating ranges. The velocity …
-
State Feedback Control of a Single-Loop Thermosyphon System Via a Quotient Controller
… to stabilize a chaotic flow in a single loop thermosyphon system with a high heat index. The thermosyphon loop is heated from below and cooled from above, which causes time-dependent chaotic flow when the external heat index is above a threshold value. Our goal was to stabilize the fluid into …
-
A cooling system using two-phase closed thermosyphon for telecommunication MCM: Experiment and simulation.
… is the one that employs two-phase closed thermosyphons, (i.e., wickless heat pipes) and the present study presents the results of experimental and simulation study on a cooling system using two-phase closed thermosynphons for the cooling of MCM.
-
Simulation and optimization of de-icing two-phase closed thermosyphon based on CO2 work fluid
Two phase closed Thermosyphon (TPCT) are subcategory of heat pipes based on natural circulation loop (NCL) with high performance heat transfer capacity and variety applications which are used to transfer a large range of heat through different temperatures. In general, heat pipes are a sealed …
Page 1 of 4