Reconstruction of thin lens Beta ray spectrometer
… project was to redesign and make operational a thin magnetic lens Beta-ray spectrometer which could be used to determine the beta particle spectrum emitted by radioisotopes. Since to date, data concerning the theory, operation, construction, calibration and uses of this type spectrometer is …
-
Performance investigation of a modified thin lens spectrometer
The performance of a modified thin lens spectrometer was investigated over the energy ranges provided by Pm¹⁴⁷ and Cs¹³⁷ radioactive sources. The resultant spectra and Kurie plots provided evidence of a satisfactory performance.
-
A high transmission thin lens beta-ray spectrometer
A thin lens beta-ray spectrometer has been modified to give a transmission six times that of the unmodified spectrometer at a given resolution.
-
Ring focus detection in a thin lens nuclear spectrometer
A thin lens nuclear spectrometer has been modified by the use of ring focus detection. The transmission of this spectrometer has been increased by a factor of 6 with no appreciable loss, in resolution. An examination of the beta spectrum of Eu[superscript 152,154] has been carried out with this …
-
Thin Lens-Based Geometric Surface Inversion for Multiview Stereo
… and levels of focus is developed using a thin lens model which is able to accurately model defocus blur in images. While easily stated, this requires a significant mathematical reformulation from the bottom up as the simple perspective projection assumed by the pinhole model and utilized …
-
Plokščių fotoninių elementų analizė vieno pikselio koherentiniame ir nekoherentiniame THz vaizdinime /
… masks were investigated: cubic (Airy), axicon, thin lens, and Fibonacci lens. The image was evaluated using 4 parameters: MSE, brightness, PSNR and contrast. An additional parameter, resolution, was also introduced. It is defined by spatial frequency (measured in line pairs per millimeter) when …
-
The decay of [formula omitted]
The tests of performance of the modified thin-lens magnetic spectrometer using ring-detection have been extended using improved mechanical controls of detector position. The results show only a small improvement over the performance obtained previously in this laboratory. We conclude that the limit …
-
The decay scheme of Fe⁵⁹
… gamma spectra of Fe⁵⁹ have been examined in a thin lens beta ray spectrometer. Gamma rays with energies of 1.10 Mev and 1.29 Mev were detected using the photoelectric technique with a Uranium radiator. Using a thin foil as a source, beta groups with maximum energies of 1.77 Mev and 0.45 Mev …
-
The gamma-rays of radium
The thin-lens beta-ray spectrometer is described, together with its associated equipment. The energies of gamma-rays, emitted by Radium in equilibrium with its disintegration products have been determined by measuring, in such a spectrometer, the energies of photoelectrons ejected from lead. These …
-
The decay scheme of Zn65
… from Zn⁶⁵ have been studied by means of a thin lens beta ray spectrometer. A spiral baffle was used to separate positrons from negatrons. The gamma ray spectrum in the energy range above 100 kev was found to consist of one gamma ray at 1.11 mev and annihilation radiation at 0.51 mev. One …
-
Axial alignment in a ring-collection beta-ray spectrometer
A thin-lens beta-ray spectrometer using ring-focus collection was modified. These modifications consisted of; 1) a centering mechanism enabling the source-detector axis to be aligned with the magnetic axis; 2) an extension of the vacuum chamber placing the detector further from the magnet coils. …
-
Modeling of the coherent imaging of small aerosol particles
… imaging system. Propagation through the imaging lens is examined using a thin lens model and a vector approach, the latter accounting for propagation through the imaging lens exactly. The Fresnel propagation equation is then used to calculate the intensity in the image plane. The technique has no …
-
An application of Berek's method to triplet design.
… investigation of Berekt's method of third order lens design as applied to the design of a flat field, photographic triplet. The fields of photographic triplets are usually flattened artificially by adjustment of the astigmatic image surfaces. This process results in degraded image definition in …
-
On the decay scheme of ZN"65"
… radiation from Zn⁶⁵ has been investigated in a thin lens beta ray spectrometer. A spiral baffle was used to discriminate between positrons and negatrons. Gamma ray energies of 1.12 and 1.4 mev have been measured as well as annihilation radiation of .51 mev. A positron end point at .32 mev has …
-
The gamma rays of radium and its disintegration products
… and a detailed description is given of the thin-lens beta-ray spectrometer and its auxiliary apparatus. The energies of the gamma rays of radium and of its equilibrium disintegration products are determined by measuring the momentum of the photoelectrons ejected by these gamma rays from a …
-
The Pearcey function and the cusp catastrophe
… analysis of the Pearcey function. In optics, thin lens theory supposes that all rays focus at a unique point where the field converges. For a real lens, the focal point is replaced by a cusp, which is the end point of a caustic curve dividing the bright field region from the dark. My …
-
High Dynamic Range and Omnifocus Imaging
… accurate than the conventional models (pinhole, thin-lens and Gaussian thick-lens). Our investigation of the standard models shows that the models make two implicit assumptions: first, that the aperture is coincident with the first principal plane, and second, that a point light source uniformly …
-
The beta rays of radium E and antimony 124
A thin-lens beta-ray spectrometer is described and a brief analysis of its operation is given. A coincidence Geiger-Mueller counter to be used with this instrument is also described. The spectrometer has been calibrated with a line of the thorium B spectrum, and used to obtain beta-ray spectra of …