Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 15 of 15 for “"three phase transformer"”.
-
Single-phase vs. Three-phase High Power High Frequency Transformers
… one comparison methodology for single and three-phase high power high frequency transformers in power conversion systems. The objective is to compare the volume of the transformers. And single and three-phase Dual Active Bridge Converter (DAB1 and DAB3) topologies with single and …
-
High-Power DC-DC Transformer for Medium-Voltage Grids with High-Voltage SiC Technology
… and manufacturing of a proposed solid-state transformer intended for medium-voltage applications with minimal high-frequency oscillations. Galvanic isolation on medium-voltage DC-DC converters tend to employ large number of turns in the high voltage side of the transformers leading to …
-
Fault Detection of HVDC Transformer Windings using Impedance Protection
Power transformers play a key role in high voltage direct current (HVDC) systems to overcome the limitations of conventional AC transmission and are expensive and fundamental components in power systems. Transformer winding faults are among the most frequent issues in transformers. Since winding …
-
Reduced-order modelling and simulation of integrated AC-DC systems using GAM-type dynamic phasor solution approach
… of integrated AC/DC power systems (including three-phase transformer and synchronous machine). Rigorous case studies demonstrate that the reduced-order PDP model of integrated AC/DC systems is capable of accurately tracking the steady-state and transient responses, while providing higher …
-
Power transformer magnetization under GIC/GMD
… induced currents (GIC) could saturate a transformer core. Two significant effects are the abnormal stray flux in transformers and extremely large harmonic contents in excitation currents, which can lead to serious equipment damage and power system misoperation. Such incidents have …
-
Model Order Reduction: Application to Electromagnetic Problems
… method, are compared to reduce the assembly phase. The parametric dependencies are taken into account by resorting to global reduced basis and nonlinear interpolation on manifolds techniques. Finally, a novel decoupled approach for the reduction of a coupled nonlinear magnetodynamic …
-
Computerized Distribution System Protection Program
… subtransmission voltage to distribution voltage transformers, and distribution lines are all represented as impedances in the three networks. Conductor size, type, and configuration and transformer impedances vary from one distribution system fault study to another, but the basic goal, dividing …
-
Parameter estimation for transformer modeling
Large Power transformers, an aging and vulnerable part of our energy infrastructure, are at choke points in the grid and are key to reliability and security. Damage or destruction due to vandalism, misoperation, or other unexpected events is of great concern, given replacement costs upward of $2M …
-
Condition Assessment of Power Transformer Winding Insulation Based on Partial Discharge Detection
Power transformers are important components of power systems, as their failure can result in major losses to electric utilities. Transformer windings are responsible for approximately 30% of transformer failures. A principal cause of these failures is winding insulation failure due to partial …
-
Resonant overvoltage phenomena associated with transformer feeders
… transient voltages generated in composite transformer feeders, particularly due to resonance. The thesis commences with a comprehensive review of over-voltages produced in power systems (Chapter 1). Power frequency, sustained and transient overvoltages of internal and external origin are …
-
Steady state modelling of non-linear power plant components
… the sense that they accommodate all the nodes. phases and the full spectrum of coefficients of the orthogonal basis. Linear and linearised, non-linear elements can be combined in the same frame of reference for a unified solution. In rigorous waveform distortion analysis. accurate representation …
-
Snížení zapínacího proudu transformátoru
V této diplomové práci je popsána funkce a návrh transformátoru navrženého na feromagnetickém jádře, složeného z transformátorových plechů. Je vysvětlen přechodový děj a zapínací proud transformátoru. V práci jsou vložené průběhy napětí a proudu při zapínání a řešený plošný spoj, sloužící k snížení …
-
Snížení zapínacího proudu transformátoru
V této diplomové práci je popsána funkce a návrh transformátoru navrženého na feromagnetickém jádře, složeného z transformátorových plechů. Je vysvětlen přechodový děj a zapínacího proud transformátoru. V práci jsou vložené průběhy napětí a proudu, řešený plošný spoj, sloužící k snížení zapínacího …
-
Analýza a doporučení změny výkonového přepínače
V této bakalářské práci jsou popsány možnosti regulace napětí transformátorů, výkonových transformátorů a druhy regulací. Dále je zde popsán stav techniky výkonových přepínačů a uvedeni někteří významní výrobci regulací. Také je zde uvedena revize přepínače MR MI501 a výměna přepínače Škoda OPZ za …