Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 15 of 15 for “"three phase transformer"”.

  1. Single-phase vs. Three-phase High Power High Frequency Transformers

    … one comparison methodology for single and three-phase high power high frequency transformers in power conversion systems. The objective is to compare the volume of the transformers. And single and three-phase Dual Active Bridge Converter (DAB1 and DAB3) topologies with single and …

    vt Repository record for Single-phase vs. Three-phase High Power High Frequency Transformers (opens in a new tab)

  2. High-Power DC-DC Transformer for Medium-Voltage Grids with High-Voltage SiC Technology

    … and manufacturing of a proposed solid-state transformer intended for medium-voltage applications with minimal high-frequency oscillations. Galvanic isolation on medium-voltage DC-DC converters tend to employ large number of turns in the high voltage side of the transformers leading to …

    arkansas Repository record for High-Power DC-DC Transformer for Medium-Voltage Grids with High-Voltage SiC Technology (opens in a new tab)

  3. Fault Detection of HVDC Transformer Windings using Impedance Protection

    Power transformers play a key role in high voltage direct current (HVDC) systems to overcome the limitations of conventional AC transmission and are expensive and fundamental components in power systems. Transformer winding faults are among the most frequent issues in transformers. Since winding …

    chalmers Repository record for Fault Detection of HVDC Transformer Windings using Impedance Protection (opens in a new tab)

  4. Reduced-order modelling and simulation of integrated AC-DC systems using GAM-type dynamic phasor solution approach

    … of integrated AC/DC power systems (including three-phase transformer and synchronous machine). Rigorous case studies demonstrate that the reduced-order PDP model of integrated AC/DC systems is capable of accurately tracking the steady-state and transient responses, while providing higher …

    ubc Repository record for Reduced-order modelling and simulation of integrated AC-DC systems using GAM-type dynamic phasor solution approach (opens in a new tab) Download PDF for Reduced-order modelling and simulation of integrated AC-DC systems using GAM-type dynamic phasor solution approach (opens in a new tab)

  5. Power transformer magnetization under GIC/GMD

    … induced currents (GIC) could saturate a transformer core. Two significant effects are the abnormal stray flux in transformers and extremely large harmonic contents in excitation currents, which can lead to serious equipment damage and power system misoperation. Such incidents have …

    vt Repository record for Power transformer magnetization under GIC/GMD (opens in a new tab)

  6. Model Order Reduction: Application to Electromagnetic Problems

    … method, are compared to reduce the assembly phase. The parametric dependencies are taken into account by resorting to global reduced basis and nonlinear interpolation on manifolds techniques. Finally, a novel decoupled approach for the reduction of a coupled nonlinear magnetodynamic …

    liege Repository record for Model Order Reduction: Application to Electromagnetic Problems (opens in a new tab) Download PDF for Model Order Reduction: Application to Electromagnetic Problems (opens in a new tab)

  7. Computerized Distribution System Protection Program

    … subtransmission voltage to distribution voltage transformers, and distribution lines are all represented as impedances in the three networks. Conductor size, type, and configuration and transformer impedances vary from one distribution system fault study to another, but the basic goal, dividing …

    sdstate Repository record for Computerized Distribution System Protection Program (opens in a new tab)

  8. Parameter estimation for transformer modeling

    Large Power transformers, an aging and vulnerable part of our energy infrastructure, are at choke points in the grid and are key to reliability and security. Damage or destruction due to vandalism, misoperation, or other unexpected events is of great concern, given replacement costs upward of $2M …

    mtu Repository record for Parameter estimation for transformer modeling (opens in a new tab)

  9. Condition Assessment of Power Transformer Winding Insulation Based on Partial Discharge Detection

    Power transformers are important components of power systems, as their failure can result in major losses to electric utilities. Transformer windings are responsible for approximately 30% of transformer failures. A principal cause of these failures is winding insulation failure due to partial …

    waterloo Repository record for Condition Assessment of Power Transformer Winding Insulation Based on Partial Discharge Detection (opens in a new tab)

  10. Resonant overvoltage phenomena associated with transformer feeders

    … transient voltages generated in composite transformer feeders, particularly due to resonance. The thesis commences with a comprehensive review of over-voltages produced in power systems (Chapter 1). Power frequency, sustained and transient overvoltages of internal and external origin are …

    strathclyde Repository record for Resonant overvoltage phenomena associated with transformer feeders (opens in a new tab)

  11. Steady state modelling of non-linear power plant components

    … the sense that they accommodate all the nodes. phases and the full spectrum of coefficients of the orthogonal basis. Linear and linearised, non-linear elements can be combined in the same frame of reference for a unified solution. In rigorous waveform distortion analysis. accurate representation …

    glasgow Download PDF for Steady state modelling of non-linear power plant components (opens in a new tab)

  12. Snížení zapínacího proudu transformátoru

    V této diplomové práci je popsána funkce a návrh transformátoru navrženého na feromagnetickém jádře, složeného z transformátorových plechů. Je vysvětlen přechodový děj a zapínací proud transformátoru. V práci jsou vložené průběhy napětí a proudu při zapínání a řešený plošný spoj, sloužící k snížení …

    brno-tech Repository record for Snížení zapínacího proudu transformátoru (opens in a new tab)

  13. Snížení zapínacího proudu transformátoru

    V této diplomové práci je popsána funkce a návrh transformátoru navrženého na feromagnetickém jádře, složeného z transformátorových plechů. Je vysvětlen přechodový děj a zapínacího proud transformátoru. V práci jsou vložené průběhy napětí a proudu, řešený plošný spoj, sloužící k snížení zapínacího …

    brno-tech Repository record for Snížení zapínacího proudu transformátoru (opens in a new tab)

  14. Analýza a doporučení změny výkonového přepínače

    V této bakalářské práci jsou popsány možnosti regulace napětí transformátorů, výkonových transformátorů a druhy regulací. Dále je zde popsán stav techniky výkonových přepínačů a uvedeni někteří významní výrobci regulací. Také je zde uvedena revize přepínače MR MI501 a výměna přepínače Škoda OPZ za …

    brno-tech Repository record for Analýza a doporučení změny výkonového přepínače (opens in a new tab)