  1. A three phase short circuit analysis of the Naval Weapons Laboratory electrical distribution system

    A three phase short circuit analysis was performed on an existing industrial distribution system. Justifications and reasons for carrying out such a study are discussed, along with the calculating procedures, assumptions, and techniques. Sample calculations are illustrated, and a complete tabular …

    vt Repository record for A three phase short circuit analysis of the Naval Weapons Laboratory electrical distribution system (opens in a new tab)

  2. Evaluation of the damping effect of ammortisseur currents in a synchronous machine

    … computer. The cases analyzed include the solid three phase short circuit with and without associated changes in speed, the frequency of rotor oscillation following a disturbance and the effect of the damper winding on these transients. Specific results were obtained using a set of machine …

    ut-knoxville Repository record for Evaluation of the damping effect of ammortisseur currents in a synchronous machine (opens in a new tab)

  3. Phase-domain synchronous generator model for transients simulation

    Three-phase synchronous generators which convert mechanical energy into electrical energy are the main power sources of power systems. In this thesis a phase-domain synchronous generator model which is developed directly in the stator reference frame is presented. The electrical and mechanical …

    ubc Repository record for Phase-domain synchronous generator model for transients simulation (opens in a new tab) Download PDF for Phase-domain synchronous generator model for transients simulation (opens in a new tab)

  4. Comparison of control strategies for squirrel-cage induction generator-based wind energy conversion systems

    … does not have the best inrush current. Tests of three-phase short circuit and rejection of load were also carried out and the results suggest that the machine-side control is not affected significantly.

    brazil-ufrn Repository record for Comparison of control strategies for squirrel-cage induction generator-based wind energy conversion systems (opens in a new tab)

  5. Mitigating the erosion of transient stability margins in Great Britain through novel wind farm control techniques

    … a representative reduced test system following a three-phase short-circuit fault occurring on one of the two double-circuits constituting the B6 boundary, the impacts on the transient stability margins are qualitatively identified. There is a pressing necessity for new wind farms to be able to …

    strathclyde Repository record for Mitigating the erosion of transient stability margins in Great Britain through novel wind farm control techniques (opens in a new tab)

  6. Dynamický model a odbuzení bezkartáčového synchronního generátoru

    Tato diplomová práce je zaměřena na analýzu matematického modelu synchronního stroje. Na základě analýzy je v práci sestaven matematický model hlavního a budicího synchronního generátoru v bezkartáčovém systému buzení. Matematické modely obou strojů jsou vytvořeny na základě soustav diferenciálních …

    brno-tech Repository record for Dynamický model a odbuzení bezkartáčového synchronního generátoru (opens in a new tab)

  7. Transient analysis and modelling of multimachine systems with power electronics controllers for real-time application

    … This is significant since asymmetrical short-circuit faults constitute the largest percentage of faults that occur in the power network, and network designs based solely on the three-phase short-circuit-to-ground faults result in underengineered networks. Equally important issues are the …

    glasgow Download PDF for Transient analysis and modelling of multimachine systems with power electronics controllers for real-time application (opens in a new tab)

  8. Analýza účinků zkratového proudu v rozváděči

    Tato práce je zaměřena na problematiku dynamických účinků zkratových proudů, přesněji dynamických účinků zkratových proudů na rozváděč (kabelovou koncovku). Práce byla určena pro konkrétní konstrukční zadání dvou rozváděčových skříní umístěných na točivých strojích firmy Siemens Electric Machines …

    brno-tech Repository record for Analýza účinků zkratového proudu v rozváděči (opens in a new tab)

  9. Zkratové poměry v rozvodně 110 kV Sokolnice po zavedení přímé transformace 400/110 kV

    Cílem této bakalářská práce je vyšetřit zkratové poměry v rozvodně Sokolnice 110kV před a po instalaci transformátoru T402 – před a po zavedení přímé transformace 400/110kV. Určením těchto poměrů zjistit, jestli vyhoví původní instalované ochranné prvky (výkonové vypínače) v rozvodně. Práce je …

    brno-tech Repository record for Zkratové poměry v rozvodně 110 kV Sokolnice po zavedení přímé transformace 400/110 kV (opens in a new tab)

  10. Analýza mechanického namáhání při zkratu ve vzduchem izolovaném rozváděči vn

    Tato diplomová práce je zaměřena na problematiku silových účinků magnetického pole zkratového proudu. V první části práce bylo úkolem provést analýzu vzájemného silového působení tří fázových přípojnic během třípólového zkratu. Analýza byla provedena v programu Ansys Maxwell. Následně jsem …

    brno-tech Repository record for Analýza mechanického namáhání při zkratu ve vzduchem izolovaném rozváděči vn (opens in a new tab)