Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 47 for “"tie-lines"”.

  1. Experimental Determination of Tie-Lines in the Hg-Cd-Te System

    An attempt has been made to determine the tie-lines at 500° C in the HgCd-Te system using quantitative analysis with the help of energy dispersive X-ray analysis (EDAX) on a scanning electron microscope. The tie-lines were determined from bulk specimens equilibrated at 500° C. The solid solution …

    marquette Repository record for Experimental Determination of Tie-Lines in the Hg-Cd-Te System (opens in a new tab)

  2. Robust out-of-step relay protection logic using conventional blinder technology for tie-lines to the eastern interconnection

    Development of reliable out-of-step protective relay logic for use in microprocessor relays that utilize conventional blinder technology. Extensive relay lab testing via a custom battery of tests generated both synthetically and from real world captured fault data are used to determine if the …

    ttu Repository record for Robust out-of-step relay protection logic using conventional blinder technology for tie-lines to the eastern interconnection (opens in a new tab)

  3. The Modification of Solvents for Liquid-Liquid Extraction Processes

    … literature relating to desirable solvent properties, variations in solvent use, methods of determining, representing, interpolating, extrapolating and predicting liquid-liquid equilibria and the fundamentals of mass transfer has been critically reviewed. The use of pro- and anti-solvents to …

    aston Repository record for The Modification of Solvents for Liquid-Liquid Extraction Processes (opens in a new tab) Download PDF for The Modification of Solvents for Liquid-Liquid Extraction Processes (opens in a new tab)

  4. Composite System based Multi-Area Reliability Evaluation

    … is typically done by considering equivalent tie lines between different areas in an integrated power system. It gives approximate results for the reliability indices of a power system as it models each of the areas as a single node to which are connected the entire area generation and loads. …

    tamu Repository record for Composite System based Multi-Area Reliability Evaluation (opens in a new tab)

  5. Emergency stability control of power systems using wide area synchrophasor measurements

    … one to prevent cascaded tripping of transmission lines due to overloading when a major tie-line exporting power is tripped and the other to prevent uncontrolled islanding and blackouts due to transient instability, were developed. The RAS proposed for overload prevention in Manitoba Hydro grid …

    manitoba Repository record for Emergency stability control of power systems using wide area synchrophasor measurements (opens in a new tab)

  6. Improvements in phase behavior modeling for compositional simulation

    … in very large capillary pressure values. The “tie-simplex-based (TSB) phase behavior modeling” techniques attempt to speed up phase behavior calculations by skipping stability analysis and preconditioning phase-split calculations. We implemented the compositional space adaptive tabulation …

    texas Repository record for Improvements in phase behavior modeling for compositional simulation (opens in a new tab)

  7. Application of miscibility calculations to gas floods

    … The approach relies on finding key crossover tie lines for a dispersion-free displacement using method of characteristic theory (MOC). The new method, however, differs from published methods by significantly reducing the number of equations and unknown parameters, and by providing a fast and …

    texas Repository record for Application of miscibility calculations to gas floods (opens in a new tab)

  8. Real-time Voltage Stability Monitoring and Control for Load Areas: A Hybrid Approach

    … stability of a load area fed by <em>N</em> tie lines. This hybrid approach integrates both simulation-based and measurement-based approaches for voltage stability assessment (VSA).</p> <p>First, for measurement-based VSA (MBVSA), a new method is proposed for monitoring and control of load …

    utk-theses Repository record for Real-time Voltage Stability Monitoring and Control for Load Areas: A Hybrid Approach (opens in a new tab)

  9. Bolted Connection Strength in Pultruded Glass Fiber Reinforced Polymer Structural Shapes

    … are just a few of the advantageous properties of pultruded fiber reinforced polymer (FRP) composites. The various structural applications of pultruded materials typically require the joining of composites either to composites or to metals. Despite introducing high stress concentrations in …

    wvu Repository record for Bolted Connection Strength in Pultruded Glass Fiber Reinforced Polymer Structural Shapes (opens in a new tab)

  10. Advances in calculation of minimum miscibility pressure

    … that our mixing cell method finds all the key tie lines predicted by MOC; however, the method proved to be more robust and reliable than current analytical methods. Second, we identify a number of problems with analytical methods of MMP estimation, and demonstrate them using real oil …

    texas Repository record for Advances in calculation of minimum miscibility pressure (opens in a new tab)

  11. Fast and robust phase behavior modeling for compositional reservoir simulation

    … novel transformation method. In this method, all tie lines in ternary systems are first transformed to a new compositional space where all tie lines are made parallel. The binodal curves in the transformed space are regressed with any accurate function. Equilibrium phase behavior calculations are …

    texas Repository record for Fast and robust phase behavior modeling for compositional reservoir simulation (opens in a new tab)

  12. Thermodynamics and Kinetics for the Pearlite Reaction in Chromium Steels

    … data. The experimentally determined tie-lines are in good agreement with the calculated phase diagrams.</p> <p>The pearlite growth rates and interlamellar spacings in a series of low chromium Fe-C-Cr alloys have been experimentally determined. The growth rates in these alloys are …

    mcmaster Repository record for Thermodynamics and Kinetics for the Pearlite Reaction in Chromium Steels (opens in a new tab)

  13. The Role of Manganese in the Formation of Proeutectoid Ferrite

    … thermodynamic data. Experimentally determined tie-lines are in good agreement with the calculated diagram. </p> <p> It has been shown that the assumption that the austenite-ferrite interface is in a local equilibrium condition during the late stages of the transformation in highly …

    mcmaster Repository record for The Role of Manganese in the Formation of Proeutectoid Ferrite (opens in a new tab)

  14. Inter-area oscillation damping in large scale power systems with unified power flow controllers

    … These oscillations do not usually damp out in tie-lines unless certain controls are applied to the system. Local and inter-area oscillations have traditionally been controlled by Power System Stabilizers (PSS). However, Flexible Alternating Current Transmission Controllers (FACTS) have …

    must-thes Repository record for Inter-area oscillation damping in large scale power systems with unified power flow controllers (opens in a new tab)

  15. Simultaneous Fit of Liquidus Lines & Gibbs Free Energies of Formation of Crystalline Compounds Using Several Liquid Solution Models

    … determination of phase diagrams including tie lines can be prohibitively time consuming. Consequently many attempts have been made at developing liquid solution models that can provide a general understanding of binary, pseudo-binary, and even ternary systems in the hope of using such …

    marquette Repository record for Simultaneous Fit of Liquidus Lines & Gibbs Free Energies of Formation of Crystalline Compounds Using Several Liquid Solution Models (opens in a new tab)

  16. Performance Enhancement of Automatic Generation Control by Developing a Detailed Load Frequency Control Model and an Adaptive Performance Index Criterion

    … control areas are connected to each other by tie-lines and power is transferred between control areas based on a specific schedule. The second objective of automatic generation control is to keep the tie-lines power flow close to their secluded values.;An accurate and realistic load frequency …

    wvu Repository record for Performance Enhancement of Automatic Generation Control by Developing a Detailed Load Frequency Control Model and an Adaptive Performance Index Criterion (opens in a new tab)

  17. Control Applications and Economic Evaluations of Distributed Series Reactors in Unbalanced Electrical Transmission Systems

    … without construction of new transmission facilities, all while assuring secure operation of the grid. New technologies can enhance efficiency and reliability, increase capacity utilization, enable more rapid response to contingencies, and increase flexibility in controlling power flows on …

    vt Repository record for Control Applications and Economic Evaluations of Distributed Series Reactors in Unbalanced Electrical Transmission Systems (opens in a new tab)

  18. WAMS-based Intelligent Load Shedding Scheme for Preventing Cascading Blackouts

    … the effectiveness of AGC Scheme by observing tie line flows and the speed of operation of the UFLS Scheme by shedding loads intelligently, to preserve system integrity in the event of an evolving cascading failure. The proposed scheme detects and estimates the size of an event by monitoring …

    vt Repository record for WAMS-based Intelligent Load Shedding Scheme for Preventing Cascading Blackouts (opens in a new tab)

  19. INCORPORATING GENERATING UNIT MAINTENANCE SCHEDULING IN POWER SYSTEM RELIABILITY EVALUATION

    … companies, and independent systems connected by tie lines. The research and the developed concepts presented in this thesis should prove valuable to those responsible for maintenance planning in electric power systems.

    sask Repository record for INCORPORATING GENERATING UNIT MAINTENANCE SCHEDULING IN POWER SYSTEM RELIABILITY EVALUATION (opens in a new tab)

  20. Cholesterol-induced domain formation in multi-component lipid membranes

    … critical point as well as the slope of tie lines, but not the compositions of the coexisting phases.

    ttu Repository record for Cholesterol-induced domain formation in multi-component lipid membranes (opens in a new tab)

Page 1 of 3