Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 34 for “"time gating"”.

  1. Design of a remotely controlled pseudo-random generator with local time gating

    … or use of the device by unauthorized persons, a time gate is included in the operation. Recommendations for implementation are presented.

    nps Repository record for Design of a remotely controlled pseudo-random generator with local time gating (opens in a new tab)

  2. Sidelobe suppression in chirp radar systems

    … of "passive generation" lies in the infinite time required for transmission of the resultant pulse, This means that some chirp radar systems may require time gating before transmission of the pulse. Time gating becomes necessary when the time-bandwidth product (Dispersion Factor) is less than …

    njit Repository record for Sidelobe suppression in chirp radar systems (opens in a new tab)

  3. SNM neutron detection using a time-gated synthetic aperture hybrid approach

    … as a large area system enables one to apply time gating the source-detector response to maximize signal to noise responses from a passing source with minimal background; multiple units may be positioned as a collective synthetic aperture detector array to be used as a way of performing real …

    gatech Repository record for SNM neutron detection using a time-gated synthetic aperture hybrid approach (opens in a new tab)

  4. Average Dielectric Property Analysis of Non-Uniform Structures: Tissue Phantom Development, Ultra-Wideband Transmission Measurements, and Signal Processing Techniques

    … over a range of frequencies. First, time-gating is used to reduce multipath. Second, the antenna response is deconvolved from the measured data. Finally, with the object-under-test's response isolated, the average properties are estimated. To test and validate this work, dielectric …

    calgary Repository record for Average Dielectric Property Analysis of Non-Uniform Structures: Tissue Phantom Development, Ultra-Wideband Transmission Measurements, and Signal Processing Techniques (opens in a new tab)

  5. GDOT: Gated Diffuse Optical Tomography

    Time-of-flight diffuse optical tomography (ToF-DOT) is a promising technology for non-invasive functional neuroimaging. Such an imaging device could lead to wearable brain-computer interfaces (BCIs) for prosthetics and faster communication. Unfortunately, ToF-DOT suffers from low spatial resolution …

    rice Repository record for GDOT: Gated Diffuse Optical Tomography (opens in a new tab)

  6. Command Wire Sensor Measurements

    … close-in clutter rejection by utilizing time gating. Recommendations for future work were proposed to gather more data to support the ongoing NPS research on the Command Wire Sensor design.

    nps Repository record for Command Wire Sensor Measurements (opens in a new tab)

  7. Simultaneous dual-color 3D stimulated emission depletion microscopy

    … can be further enhanced by using the arrival time of spontaneous emission by time-gating the detection.

    lmu-germany Repository record for Simultaneous dual-color 3D stimulated emission depletion microscopy (opens in a new tab)

  8. Single molecule detection in solution

    … using Iciser-induced fluorescence with time-gated photon counting to isolate solvent molecule signals from promptly scattered light. Compared to prior experiments, the system sensitivity is improved by over an order of magnitude with more efficient light collection and a custom-modified …

    utk-theses Repository record for Single molecule detection in solution (opens in a new tab)

  9. Ultrasonic signal processing and classification using principal component analysis

    … is required in this classification consisting of time gating, normalization, and signal alignment. Additionally, PCA is computed on transform domain signals including the Fourier transform, Wavelet transform, and Cosine transform. The results indicate that PCA may be useful to significantly reduce …

    iastate Repository record for Ultrasonic signal processing and classification using principal component analysis (opens in a new tab)

  10. Optimization of reflector and transducer properties for surface acoustic wave devices on 128° LiNbO3

    … of the grating are extracted applying time gating to the test structure responses. Both their amplitudes and phases are evaluated. The former is used for obtaining the reflectivity of the reflectors. Furthermore, energy comparisons serve to address the attenuation inside the gratings, …

    aalto Repository record for Optimization of reflector and transducer properties for surface acoustic wave devices on 128° LiNbO3 (opens in a new tab)

  11. ENGINEERING COPPER-VACANCY COLOR CENTERS IN ZINC SULFIDE FOR QUANTUM DEFECT DISCOVERY

    … such as emission wavelength, spin coherence time, and pathways for device integration. A key challenge is obtaining materials that contain defects of interest, and at sufficiently low concentrations to allow observation of quantum emission. This thesis concerns the creation of copper-vacancy …

    penn Repository record for ENGINEERING COPPER-VACANCY COLOR CENTERS IN ZINC SULFIDE FOR QUANTUM DEFECT DISCOVERY (opens in a new tab) Embargoed until 2027-08-28

  12. Arrays of quantum-light-emitting diodes with site-controlled pyramidal quantum dots

    … be reduced to 0.078 0.066 when combined with a time-gating technique under pulse exciation. On the other hand, the fidelities to the expected maximally polarizationentangled state were 0.85±0.04 under continuous excitation and 0.823±0.019 under pulse excitation by assistance of time-gating, with …

    cork Repository record for Arrays of quantum-light-emitting diodes with site-controlled pyramidal quantum dots (opens in a new tab)

  13. Long-lived Luminescent Metal Complexes for Molecules Sensing and Nanotube Dispersion

    … quantum efficiency and radiative emission lifetime. Moreover, the emission wavelength of metal complexes can be easily tuned through the ligand modification and the change of central metals. Ruthenium(II) and Iridium(III)-based complexes have d6 electronic structures. The advantageous …

    rice Repository record for Long-lived Luminescent Metal Complexes for Molecules Sensing and Nanotube Dispersion (opens in a new tab)

  14. METHODS FOR CHARACTERIZING ELECTROMAGNETIC COUPLING STATISTICS IN COMPLEX ENCLOSURES

    … measurement methods are developed that use the time gating technique to acquire the nonrandom system parameters. Additionally, a problematic case of high loss antenna in enclosures is addressed. For the high loss antenna case, the radiation impedance is very difficult to obtain and difficult to …

    maryland Repository record for METHODS FOR CHARACTERIZING ELECTROMAGNETIC COUPLING STATISTICS IN COMPLEX ENCLOSURES (opens in a new tab)

  15. Tunable Single-Photon Nonlinearities at Room Temperature: Polaronic Optical Gunn Effect in Individual Carbon Nanotubes

    … g²(τ) analysis, Mandel Q-parameter time-gating, and Buffon's needle stochastic modeling—enabling reliable identification of individual quantum emitters. Our central discovery is the polaronic optical Gunn effect, a novel room-temperature quantum phenomenon with transformative …

    wurz-thes Repository record for Tunable Single-Photon Nonlinearities at Room Temperature: Polaronic Optical Gunn Effect in Individual Carbon Nanotubes (opens in a new tab)

  16. Optimization-Based Approaches to Low-Coherence Optical Diffraction Tomography

    … illumination in ODT and showed that it enables time-gating of artifacts caused by multiple-scattering. I have further demonstrated that ODT combined with Fourier-transform spectroscopy can be used for spectral tomographic imaging of the wavelength-dependent complex-valued refractive index …

    ucf Repository record for Optimization-Based Approaches to Low-Coherence Optical Diffraction Tomography (opens in a new tab)

  17. DEVELOPMENT OF A MULTIPLEXED CONFOCAL FLUORESCENCE LIFETIME IMAGING MICROSCOPE FOR SCREENING APPLICATIONS

    … is by quantifying changes in fluorescence lifetime using Fluorescence lifetime imaging microscopy (FLIM). The change in fluorescence lifetime is inversely proportional to the ratio of bound to non-bound proteins. Tradition FLIM-FRET microscopy is too slow for screening applications. Our aim was …

    mcmaster Repository record for DEVELOPMENT OF A MULTIPLEXED CONFOCAL FLUORESCENCE LIFETIME IMAGING MICROSCOPE FOR SCREENING APPLICATIONS (opens in a new tab)

  18. Synthesis and regeneration of advanced optical modulation formats

    … the use of a delay line interferometer (DLI), time gating and coherent temporal superposition. A BPSK seed signal was used to generate QPSK (with a single DLI) and 16-QAM (with two concatenated DLIs) signals. The all-optical regeneration schemes studied in this thesis take several forms: phase …

    soton Download PDF for Synthesis and regeneration of advanced optical modulation formats (opens in a new tab)

  19. Design of Time-Gated CMOS SPADs Towards High-Performance Imagers

    … positron emission tomography, fluorescence lifetime imaging, light detection and ranging, and more. SPAD fabrication has shifted recently towards custom technologies, 3D stacked designs, and post-processing steps (micro-lenses) to improve performance at the expense of increased cost and …

    mcmaster Repository record for Design of Time-Gated CMOS SPADs Towards High-Performance Imagers (opens in a new tab)

Page 1 of 2