Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 9 of 9 for “"time varying impedance"”
-
Cooperative impedance control with time-varying stiffness
… with the environment. One approach is to use impedance control to specify a relationship between a robot's motion and force and control a grasped object's apparent stiffness, damping, and inertia. Conventional impedance control practices have focused on position-based manipulators - which are …
-
ANTHROPOMORPHIC ROBOTIC ANKLE-FOOT PROSTHESIS WITH ACTIVE DORSIFLEXION- PLANTARFLEXION AND INVERSION-EVERSION
… of freedom (DOF) controlled using admittance and impedance controllers is presented. Also, a novel testing apparatus for estimation of the ankle mechanical impedance in two DOF is presented. The testing apparatus allows the estimation of the time-varying impedance of the human ankle in stance …
-
Simulation of Human Ankle Trajectory during Stance Phase of Gait
… trajectory. This simulation also estimates the impedance of the human ankle based on the ground reaction forces measured by the force plate. This simulation will accept alterations of the following parameters: total body weight, weight of the shank, weight of the foot, trajectories of the shank …
-
An Active Quasi-Circulator IC and Technique for 1-255 MHz Resonance-Based Spectroscopic Impedance Plethysmography
Impedance measurement is a promising avenue for noninvasive glucosemonitoring. Specifically,resonance-basedimpedancemeasurements exhibit good correlation with glucose levels at excitations from tens of MHztoover 100 MHz. Additionally, plethysmographic impedance measurements are needed to separate …
-
Hybrid Silicon Mode-Locked Laser with Improved RF Power by Impedance Matching
… optical fiber communications based on optical time-division multiplexing (OTDM) systems. Integrating mode-locked lasers on silicon makes way for highly integrated silicon based photonic communication devices. The mode-locked laser being used in this thesis was built with Hybrid Silicon …
-
Design of a Quasi-Adiabatic Current-Mode Neurostimulator Integrated Circuit for Deep Brain Stimulation
… seen across the electrodes (>10V) due to the time-varying impedance presented by the electrode-tissue interface. The overall efficiency of the designed CMS is limited by the efficiency of the DHVS. A HVDD of 15V is created by the DHVS from an input voltage (VDD) of 3V. The DHVS circuit is made …
-
Wearable Bio-Impedance Sensing Methods for Continuous Monitoring of Hemodynamic Parameters
… The pulse morphology and pulse transit time (PTT) which is the time taken by the pressure pulse to travel between two points in an arterial vessel are highly correlated with the BP. In this dissertation, we present a new cuffless BP method using an array of wrist-worn bio-impedance …
-
Design and operation of a 45 μs repetitively pulsed 12 mw electron beam for a CO₂ laser
… and implemented which can operate over a 6:1 impedance range. The system consists of a 150 kV – 250 kV modulator and a large area, (2.500 cm²) 5-20 mλ /cm² hot-cathode electron-beam gun. The system is designed and fabricated to be used in conjunction with an electron beam sustained laser and …
-
Zpracování bioimpedančního signálu
… se zabývá vlastnostmi, měřením a využitím bioimpedance pro lékařskou diagnostiku. Praktická část se věnuje detekci významných bodů v derivovaném bioimpedančním signálu, které mohou být využity v různých lékařských aplikacích. Práce srovnává 3 detekční algoritmy. Nejlepších výsledků dosahuje …