Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 131 for “"time-domain reflectometry (TDR)"”

  1. Time domain reflectometry (TDR) techniques for the design of distributed sensors

    … of a working system. The system consists of time domain reflectometry (TDR) signal processing equipment and specially designed sensing cables. The TDR equipment sends a high-frequency electric pulse (in the gigahertz range) along the sensing cable. Any change in electric impedance along the …

    vt Repository record for Time domain reflectometry (TDR) techniques for the design of distributed sensors (opens in a new tab)

  2. The use of time domain reflectometry (TDR) to determine and monitor non-aqueous phase liquids (NAPLS) in soils

    This research deals with the potential use(s) of Time Domain Reflectometry (TDR) to determine and monitor Non-Aqueous Phase Liquids (NAPLs) in soils. TDR is an established method to determine water content and electrical conductivity of soils. Other applications include solute transport and NAPLs …

    ohiolink Repository record for The use of time domain reflectometry (TDR) to determine and monitor non-aqueous phase liquids (NAPLS) in soils (opens in a new tab)

  3. Análise de falhas dos cabos utilizados nas redes metálicas em telecomunicações com as técnicas de Time Domain Reflectometry (TDR)

    … no domínio do tempo do espectro de dispersão (SSTDR) e a reflectometria no domínio do tempo de sequência (STDR). São analisados os sinais comumente presentes nos cabos telefônicos, com o objetivo de localizar falhas intermitentes. Essa análise se faz necessária porque a linha telefônica, …

    brazil-ufrgs Repository record for Análise de falhas dos cabos utilizados nas redes metálicas em telecomunicações com as técnicas de Time Domain Reflectometry (TDR) (opens in a new tab)

  4. Extraction of frequency dependent parameters of RG59/U coaxial cable using time domain reflectometry

    … parameters of RG59/U cable parameters by using Time Domain Reflectometry (TDR) measurements and demonstrates that TDR measurements have practical use for identifying cable parameters. The frequency-dependent parameters are resistance, inductance, conductance, and capacitance (R(f), L(f), G(f), …

    texas Repository record for Extraction of frequency dependent parameters of RG59/U coaxial cable using time domain reflectometry (opens in a new tab) Restricted access

  5. Moisture content measurements using time-domain techniques

    In this thesis, the time-domain reflectometry (TDR) technique applied to moisture con­tent measurements of the dispersive and porous dielectric substance is studied. The TDR sensors with uniform sensitivity and definite sampling volume are proposed. Their charac­teristics are studied theoretically …

    uvic Repository record for Moisture content measurements using time-domain techniques (opens in a new tab)

  6. Mechanism of sloping capillary barriers under high rainfall conditions

    … such as pressure transducer-tensiometer system; time domain reflectometry (TDR); magnetic flowmeter and electronic weight balances. Rainfalls of different intensities and durations can be simulated through a rainfall simulator located at the top of the infiltration box.

    nanyang Repository record for Mechanism of sloping capillary barriers under high rainfall conditions (opens in a new tab)

  7. Time domain transmission line measurements with the speedy delivery signal

    … Use of the SD waveform allows for high precision time domain measurements on transmission lines. High precision time domain reflectometry (TDR) and time domain transmission (TDT) measurements are described. An example measurement is presented. The design of the experimental apparatus is detailed. …

    texas Repository record for Time domain transmission line measurements with the speedy delivery signal (opens in a new tab)

  8. The Role of residual stresses in ceramic substrate materials for hybrid thick film applications

    … are also tested for electrical performance using Time Domain Reflectometry (TDR) technique. This thesis presents results that indicate that significant tensile residual stresses were generated on the back of the substrate, particularly during the laser scribing phase of the finished device. …

    vt Repository record for The Role of residual stresses in ceramic substrate materials for hybrid thick film applications (opens in a new tab)

  9. Influence of Soil Capping Depth on Water Dynamics in Phosphogypsum Stack Reclamation

    … capping soil required for PG stack reclamation. Time Domain Reflectometry (TDR), MPS-1 matric potential sensors and conservative tracer application were used to assess water balance across capping soil depths. Results from the varying experiments indicated that an increase in capping soil depth …

    alberta Repository record for Influence of Soil Capping Depth on Water Dynamics in Phosphogypsum Stack Reclamation (opens in a new tab)

  10. A simulation study on locating water trees on single core XLPE underground cables using reflectometry diagnosis techniques

    … this goal, two wave propagation techniques: time domain reflectometry (TDR) and frequency domain reflectometry (FDR) are evaluated on its performance on locating water-trees on cable's insulation. Water treeing is a degradation of cable's insulation due to a high level of moisture that causes …

    uniandes Repository record for A simulation study on locating water trees on single core XLPE underground cables using reflectometry diagnosis techniques (opens in a new tab)

  11. Detection of diesel leakage from underground storage tank using time domain reflectometry

    … requirements are achieved. We find in our study time domain reflectometry (TDR) can be used to detect leaks from an UST. The magnitudes of reflections measured by the TDR technique are used to calculate electrical properties of the soil. We find the introduction of diesel fuel, a light nonaqueous …

    umkc Repository record for Detection of diesel leakage from underground storage tank using time domain reflectometry (opens in a new tab)

  12. Soil moisture variability: a field application of time domain reflectometry

    … for determining moisture content are presented: Time Domain Reflectometry (TDR), gravimetrics, porous resistance blocks and neutron scattering. The advantages and disadvantages of each method are discussed.The design of a field study using TDR for determining in situ soil moisture content is …

    carleton Repository record for Soil moisture variability: a field application of time domain reflectometry (opens in a new tab)

  13. Improving the GPR reflection method for estimating soil moisture and detection of capillary fringe and water table in a boreal agricultural field

    … compared with vertically installed 30 cm long Time Domain Reflectometry (TDR) probe data. TDR-measured and GPR-estimated SM were not significantly different, and the root mean square error (RMSE) was 0.03 m3 m-3. Second, the depth of the capillary fringe (DCF) was estimated distinguishing the …

    newfoundland Repository record for Improving the GPR reflection method for estimating soil moisture and detection of capillary fringe and water table in a boreal agricultural field (opens in a new tab)

  14. Model simplification for system-level EMI prediction and power delivery network analysis and: a transmission line sensor for crack sensing in civil concrete structures

    … power delivery network analysis in the time domain. Simplified models on a SPICE deck are desirable because of the computational efficiency, and the capability of handling active devices in a SPICE solver. The first section in this dissertation describes a statistical algorithm for …

    must-thes Repository record for Model simplification for system-level EMI prediction and power delivery network analysis and: a transmission line sensor for crack sensing in civil concrete structures (opens in a new tab)

  15. Calibration of water content reflectometer in Rocky Mountain arsenal soil

    … were analyzed to develop a calibration equation. Time domain reflectometry (TDR) technique is the most prevalent method in in-situ moisture monitoring; and WCR is a type of low frequency TDR sensors, which is sensitive to soil type. Developing soil-specific calibration and investigating different …

    texas Repository record for Calibration of water content reflectometer in Rocky Mountain arsenal soil (opens in a new tab)

  16. Application of electric polarization to contaminant detection in soils

    … The proposed approach involves adaptation of the time-domain reflectometry (TDR) concept and relies on the interraction of matter with an electric field. Analysis of the TDR data collected from soil-contaminant mixtures indicates the feasibility of a subsurface contaminant detection. The proposed …

    mcgill Repository record for Application of electric polarization to contaminant detection in soils (opens in a new tab)

  17. Innovative Non-destructive Testing Technologies for QA/QC of Fresh and Early Stage Concrete

    … and validation of a new instrument based on Time Domain Reflectometry (TDR) for measuring properties of fresh and early age concrete. It provides an alternative to traditional quality control methods that rely heavily on the slump value and compressive strength that do not always produce …

    ohiolink Repository record for Innovative Non-destructive Testing Technologies for QA/QC of Fresh and Early Stage Concrete (opens in a new tab)

  18. Electrical Design Considerations and Packaging of Power Electronic Modules

    … by the Q3D Extractor and verified by the time-domain reflectometry (TDR) measurements. In most cases, the TDR measurement results closely matched those predicted by the Q3D Extractor. These methods were applied to design and analyze a 50KVA 650V silicon carbide (SiC) half-bridge power …

    arkansas Repository record for Electrical Design Considerations and Packaging of Power Electronic Modules (opens in a new tab)

  19. Development of a field water/cement ratio test using time domain reflectometry

    … assurance. This study developed and validated a Time Domain Reflectometry (TDR) based method to quantify the real-time w/cm ratio of fresh concrete. Forty-eight concrete mixtures with varying w/cm ratios, air contents, and cementitious binder types (cement-only, fly ash, and slag) were tested, …

    ksu Repository record for Development of a field water/cement ratio test using time domain reflectometry (opens in a new tab)

  20. Time domain reflectometry waveform analysis with second order bounded mean oscillation

    <p>Time domain reflectometry (TDR) is a well-established electromagnetic technique used to estimate in situ soil water content, and thermo-TDR is an extension of the traditional TDR, which can measure both soil water content and thermal properties. Tangent line methods and adaptive waveform …

    iastate Repository record for Time domain reflectometry waveform analysis with second order bounded mean oscillation (opens in a new tab)

Page 1 of 7