Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 86 for “"tissue phantom"”.

  1. Determination of a Clinically Relevant Tissue Phantom for Transcutaneous Ultrasound Stimulation of Piezoelectric Discs for Current Density Applications

    … of piezoelectric discs [6]. The use of tissue phantoms is common in imaging ultrasound studies but has not been used in the research of stimulating piezoelectric discs with ultrasound. By comparing the power and voltage output of the same PZT disc with different tissue phantoms the …

    ku Repository record for Determination of a Clinically Relevant Tissue Phantom for Transcutaneous Ultrasound Stimulation of Piezoelectric Discs for Current Density Applications (opens in a new tab)

  2. Average Dielectric Property Analysis of Non-Uniform Structures: Tissue Phantom Development, Ultra-Wideband Transmission Measurements, and Signal Processing Techniques

    … with properties representing biological tissues and robust mechanical properties were developed. Reconfigurable tissue phantoms were created from combinations of these materials. In addition to testing the average property algorithms, these phantoms are well suited to testing a variety of …

    calgary Repository record for Average Dielectric Property Analysis of Non-Uniform Structures: Tissue Phantom Development, Ultra-Wideband Transmission Measurements, and Signal Processing Techniques (opens in a new tab)

  3. Calculation of Neutron Fluence-to-Dose Index Conversion Factors for the Standard Icru Tissue Phantom by the Monte Carlo Method

    Made available in DSpace on 2014-12-14T06:26:06Z (GMT). No. of bitstreams: 1 7811221.pdf: 6872930 bytes, checksum: f215c7f7d666eb9881298cc5aefe2a5e (MD5) Previous issue date: 1978

    uiuc Repository record for Calculation of Neutron Fluence-to-Dose Index Conversion Factors for the Standard Icru Tissue Phantom by the Monte Carlo Method (opens in a new tab)

  4. Non-Invasive Fetal Oxygenation Level Monitoring Using Time-Domain Near Infrared Spectroscopy (NIRS)

    … achieves <3% estimation error in a two-layer tissue phantom. Additionally, we perform in-vivo experiments to show that our system is able to detect reduced tissue oxygenation index (TOI) levels in a human arm, through a human tissue phantom, and can perform transabdominal fetal monitoring in …

    rice Repository record for Non-Invasive Fetal Oxygenation Level Monitoring Using Time-Domain Near Infrared Spectroscopy (NIRS) (opens in a new tab)

  5. Novel self-expanding stent retractors for neuroendoscopy

    … first part presents preliminary studies on brain tissue that have been conducted to set up an appropriate medium for SESR deployment. A finite element model of brain tissue phantom was built in Abaqus/Explicit and several surgical scenarios were simulated. The finite element model was validated …

    oxford Repository record for Novel self-expanding stent retractors for neuroendoscopy (opens in a new tab)

  6. Adaptive finite element methods for fluorescence enhanced optical tomography

    … of targets contrasted by fluorescence within the tissues from boundary fluorescence emission measurements. An adaptive finite element based reconstruction algorithm for high resolution, fluorescence tomography was developed and validated with non-contact, planewave frequency-domain fluorescence …

    tamu Repository record for Adaptive finite element methods for fluorescence enhanced optical tomography (opens in a new tab)

  7. BIOINSPIRED SURGICAL NEEDLE INSERTION MECHANICS IN SOFT TISSUES FOR PERCUTANEOUS PROCEDURES

    … force that causes needle-tip deflection, tissue deformation, and tissue damage. Recently there has been tremendous interest in the medical community to develop innovative surgical needles using biologically-inspired designs. It is well known that insects such as honeybee and mosquito steer …

    temple Repository record for BIOINSPIRED SURGICAL NEEDLE INSERTION MECHANICS IN SOFT TISSUES FOR PERCUTANEOUS PROCEDURES (opens in a new tab)

  8. A system for intraoperative transrectal ultrasound imaging in robotic-assisted laparoscopic radical prostatectomy

    … uses a registration tool pressed against an air-tissue boundary to provide common target points in the the ultrasound frame and the external frame. This method has two applications in our system: registering the ultrasound data captured by the system to a laparoscopic stereo camera to allow …

    ubc Repository record for A system for intraoperative transrectal ultrasound imaging in robotic-assisted laparoscopic radical prostatectomy (opens in a new tab) Download PDF for A system for intraoperative transrectal ultrasound imaging in robotic-assisted laparoscopic radical prostatectomy (opens in a new tab)

  9. Implanted Nanophotonic Probes for Deep Imaging in Scattering Media

    … depths of the brain is difficult since brain tissue is extremely heterogeneous, which results in strong scattering by the various tissue components and limited penetration depth as well as achievable imaging resolution. To overcome the effects of scattering, optical imaging measurement …

    rice Repository record for Implanted Nanophotonic Probes for Deep Imaging in Scattering Media (opens in a new tab)

  10. Development and evaluation of a non-invasive core temperature measurement system

    … of becoming a widely used clinical tool. In tissue phantom and human-based experiments, the prototype performed effectively and posed no safety risk. Provided the prototype can be successfully translated into a more streamlined medical device, it stands to become a staple in operating rooms …

    texas Repository record for Development and evaluation of a non-invasive core temperature measurement system (opens in a new tab)

  11. A Single Fiber System for Monitoring Tissue Oxygen Saturation

    … saturation is an important biological marker in tissue and is often quantified using optical imaging of intrinsic signals. However, due to the scattering property of biological tissue, most optical functional imaging methods are limited to the surface of the brain or have poor resolution. In this …

    calgary Repository record for A Single Fiber System for Monitoring Tissue Oxygen Saturation (opens in a new tab)

  12. ESTABLISH THE FEASIBILITY OF USING PATIENT SOURCED IMAGES FOR THE DETECTING OF JAUNDICE IN NEONATES

    … study was conducted with a bilirubin-containing tissue phantom to identify potential biological and environmental confounding factors. The findings of this study present a systematic characterization of the confounding effect of various factors through separate parametric tests. These tests …

    nus Repository record for ESTABLISH THE FEASIBILITY OF USING PATIENT SOURCED IMAGES FOR THE DETECTING OF JAUNDICE IN NEONATES (opens in a new tab) Download file for ESTABLISH THE FEASIBILITY OF USING PATIENT SOURCED IMAGES FOR THE DETECTING OF JAUNDICE IN NEONATES (opens in a new tab)

  13. A detailed design analysis of a lumenally delivered, flexible, balloon-assisted, sterile endoscopic overtube.

    … most accurate material model for human gastric tissue, FEA analysis of the balloon dilation, experimentally validating these results using a silicone tissue phantom, and the paper design of a theoretical prototype. Tensile testing the human gastric tissue provided the only material properties …

    umn Repository record for A detailed design analysis of a lumenally delivered, flexible, balloon-assisted, sterile endoscopic overtube. (opens in a new tab)

  14. Point of care diagnostics for traumatic brain injury

    … accuracy of > 93 % is demonstrated over five tissue types applied to anatomical layers of ocular porcine eyes. Subsequently, in a clinically relevant murine model of TBI, an ability to accurately identify TBI and in­jury severity from Raman spectra of the retina is demonstrated for the first …

    birmingham Download PDF for Point of care diagnostics for traumatic brain injury (opens in a new tab)

  15. Design and characterization of a hand-held, waveguide-mediated, optoacoustic imaging probe for analyzing burn wounds

    … by imaging optoacoustic targets within simple tissue phantoms. Unfortunately, enough energy could not be delivered to the hand-held probe to image tissue phantoms that resembled burns because the optical fiber used to deliver light to the waveguide could only handle a small amount of energy. …

    missouri Repository record for Design and characterization of a hand-held, waveguide-mediated, optoacoustic imaging probe for analyzing burn wounds (opens in a new tab)

  16. Performance Evaluation and Improved Permittivity Estimation for a Transmission-based Microwave Imaging System

    … is low-power, not expensive, and doesn't require tissue compression and inconvenience. Several microwave breast imaging techniques have been introduced and show both promise and limitations. The system of interest in this thesis, the transmission system, appears to have the ability to overcome …

    calgary Repository record for Performance Evaluation and Improved Permittivity Estimation for a Transmission-based Microwave Imaging System (opens in a new tab)

  17. Interferometric Synthetic Aperture Microscopy (ISAM) Reconstruction and Characterization in a High Numerical Aperture System

    … includes the image reconstruction of a tissue phantom containing nano-particles both for OCT and ISAM, and system characterization includes quantitative assessment of the confocal parameter, point spread function, and phase stability measurements. Several potential applications also are …

    uiuc Repository record for Interferometric Synthetic Aperture Microscopy (ISAM) Reconstruction and Characterization in a High Numerical Aperture System (opens in a new tab)

  18. A non-clinical method to simultaneously estimate thermal conductivity, volumetric specific heat, and perfusion of in-vivo tissue

    … specific heat, and perfusion of in-vivo tissue. The heat transfer through the tissue was modeled using a modified Pennes' equation. Using a least-squares parameter estimation method with regularization, the thermal properties could be estimated from the temperature response to the known …

    vt Repository record for A non-clinical method to simultaneously estimate thermal conductivity, volumetric specific heat, and perfusion of in-vivo tissue (opens in a new tab)

  19. Adaptive Control of Volumetric Laser Photoblation Surgery

    … is first used to demonstrate targeted soft tissue resection in porcine brain in an open-loop fashion. This device, coined the "TumorCNC" combines 3D scanning capabilities with a steerable surgical laser. Results show high variance around target cut depths which motivats the need for a …

    duke Repository record for Adaptive Control of Volumetric Laser Photoblation Surgery (opens in a new tab)

  20. Temperature-Dependent Dielectric Properties of Tissue Phantoms and Tissue Samples at Microwave Frequencies

    … dielectric properties of biological tissues is crucial in the development of ultra-wideband diagnostic and therapeutic technologies such as microwave breast cancer detection and hyperthermia treatments. This work examines the temperature dependence of the dielectric properties of the …

    mcmaster Repository record for Temperature-Dependent Dielectric Properties of Tissue Phantoms and Tissue Samples at Microwave Frequencies (opens in a new tab)

Page 1 of 5