Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 54 for “"tomograph"”.

  1. DXA measurements using a micro computed tomograph system.

    … Absorptiometry (DXA) and Quantitative Computed Tomography (QCT). The basic principle involving DXA is the ability to quantify the degree of attenuation of an energy beam after passage through bone and soft tissue. The X-ray tubes used with DXA narrow the energy beam to produce two distinct …

    louisville Repository record for DXA measurements using a micro computed tomograph system. (opens in a new tab)

  2. Iterative transmission image reconstruction for the DPET positron emission tomograph

    <p>Positron emission tomography (PET) systems use transmission imaging to compensate for attenuation. One commercial example of this approach is the Siemens Inveon Dedicated PET (DPET), a 120mm bore system dedicated to the study of small animals. DPET transmission images are currently reconstructed …

    utk-theses Repository record for Iterative transmission image reconstruction for the DPET positron emission tomograph (opens in a new tab)

  3. Development of an electrical impedance tomograph for complex impedance imaging

    … concerns the development of electrical impedance tomography towards the production of complex impedance images. The prime intention was to investigate the feasibility of developing suitable instrumentation; but not clinical applications. It was aimed to develop techniques for the performance …

    southwales Repository record for Development of an electrical impedance tomograph for complex impedance imaging (opens in a new tab) Download PDF for Development of an electrical impedance tomograph for complex impedance imaging (opens in a new tab)

  4. Crystal design simulation for a high resolution depth encoding pet tomograph

    Position Emission Tomography is a functional imaging modality where positron labeled radiotracers are used to investigate biological processes. The imaging process occurs via simultaneous detection of two 511keV gamma rays originating from positron annihilation. A PET camera is a γ detection …

    ubc Repository record for Crystal design simulation for a high resolution depth encoding pet tomograph (opens in a new tab) Download PDF for Crystal design simulation for a high resolution depth encoding pet tomograph (opens in a new tab)

  5. An analysis of counting losses in positron emission tomography

    <p>Positron Emission Tomography allows physicians and physiologist to view and quantify the chemical function of the human body. To facilitate this, the tomograph must be able to accurately measure the radioactivity presented to it. By making the assumption that the number of gamma rays seen by the …

    utk-theses Repository record for An analysis of counting losses in positron emission tomography (opens in a new tab)

  6. Implementation of a motion compensation system for high resolution brain positron emission tomography

    … during high resolution brain positron emission tomography (PET). Head motion is acknowledged as a significant source of resolution degradation in PET brain imaging; especially at the level of resolution, (2.5 mm)³ , available in the tomograph currently installed at our research centre. Several …

    ubc Repository record for Implementation of a motion compensation system for high resolution brain positron emission tomography (opens in a new tab) Download PDF for Implementation of a motion compensation system for high resolution brain positron emission tomography (opens in a new tab)

  7. Model-based randoms correction for 3D positron emission tomography

    … quantitative inaccuracies in positron emission tomography. Randoms occurring in the true coincidence window are commonly corrected for by subtracting the randoms measured in a delayed coincidence window. This requires additional processing demands on the tomograph and increases the noise in the …

    ubc Repository record for Model-based randoms correction for 3D positron emission tomography (opens in a new tab) Download PDF for Model-based randoms correction for 3D positron emission tomography (opens in a new tab)

  8. Statistical list-mode image reconstruction and motion compensation techniques in high-resolution positron emission tomography (PET)

    … suitable for high resolution positron emission tomography (PET). In particular, we have studied imaging techniques applicable to the high resolution research tomograph (HRRT): a 3Donly state-of-the-art dedicated brain tomograph. The HRRT poses a number of unique challenges, most significant of …

    ubc Repository record for Statistical list-mode image reconstruction and motion compensation techniques in high-resolution positron emission tomography (PET) (opens in a new tab) Download PDF for Statistical list-mode image reconstruction and motion compensation techniques in high-resolution positron emission tomography (PET) (opens in a new tab)

  9. Ποιοτικός έλεγχος και μελέτη των φυσικών και τεχνικών χαρακτηριστικών των σωλήνων και θαλάμων ολίσθησης MDT για την ανίχνευση μιονίων στο πείραμα ATLAS / LHC

    … of other MDT chamber types at the CERN X-ray tomograph and iii) the cosmic ray data taken by a BIS-MDT chamber at the X5/GIF (Gamma Irradiation Facility) at CERN. In more details, the study, design, development, operation, automatisation and the data analysis of a first sample of these …

    greece Repository record for Ποιοτικός έλεγχος και μελέτη των φυσικών και τεχνικών χαρακτηριστικών των σωλήνων και θαλάμων ολίσθησης MDT για την ανίχνευση μιονίων στο πείραμα ATLAS / LHC (opens in a new tab)

  10. Attenuation Correction in Positron Tomography

    … radioactivity concentrations in positron tomography. Attenuation correction can be performed using an external source of radiation and two measurements: a blank scan performed with no subject in the tomograph, and a transmission scan performed with the subject in the field of view. The …

    mcmaster Repository record for Attenuation Correction in Positron Tomography (opens in a new tab)

  11. A simulation for the design of position encoding detectors for positron emission tomography

    … of the ECAT EXACT HR PLUS positron emission tomograph. The success of the simulation in reproducing measured results is used as a validation of the simulation. The simulation is then used in an investigation of a modification to the design of the EXACT HR PLUS that would improve significantly …

    ubc Repository record for A simulation for the design of position encoding detectors for positron emission tomography (opens in a new tab) Download PDF for A simulation for the design of position encoding detectors for positron emission tomography (opens in a new tab)

  12. Magnetresonanz-Thermometrie für intradiskale Laserablationen bei 1,0 Tesla

    … wird am offenen Hochfeld- Magnetresonanz (MR)-Tomograph die intradiskale Laserablationstherapie klinisch etabliert. Eine dynamische Akquise von MR-Daten während minimalinvasiver Hochtemperatur- Verfahren eröffnet die Möglichkeit, Hitzeverteilungen im Gewebe mittels MR-Thermometrie zu …

    fu-berlin Repository record for Magnetresonanz-Thermometrie für intradiskale Laserablationen bei 1,0 Tesla (opens in a new tab)

  13. Real-time 2D and 3D electrical impedance tomography and applications

    Electrical impedance tomography (EIT) is a non-invasive and non-ionizing real-time bedside imaging modality for functional pulmonary imaging. The EIT systems produce images of impedance distributions within the body by injecting electric currents and measuring voltages on electrodes applied to the …

    colostate Repository record for Real-time 2D and 3D electrical impedance tomography and applications (opens in a new tab)

  14. Quantification and optimization techniques for dynamic brian imaging in high resolution positron emission tomography

    Modern positron emission tomography (PET) scanners have a large number of detector crystals which corresponds to an even larger number of lines of response (LOR) addressing the coincidence events. This increasing complexity makes the image reconstruction much more challenging especially in dynamic …

    ubc Repository record for Quantification and optimization techniques for dynamic brian imaging in high resolution positron emission tomography (opens in a new tab) Download PDF for Quantification and optimization techniques for dynamic brian imaging in high resolution positron emission tomography (opens in a new tab)

  15. Blood vessel diameter in glaucoma

    … progression of glaucoma. The Heidelberg Retina Tomograph (HRT) is a commercially available laser scanning ophthalmoscope designed principally for the detection of glaucoma by evaluation of the optic disc neuroretinal rim. An additional ability of the HRT is to measure, via an interactive window, …

    aston Download PDF for Blood vessel diameter in glaucoma (opens in a new tab)

  16. Fracture characterization of the hydraulic fracture test site HFTS2 with X-ray microtomography

    … inches in diameter, were moved into the micro-tomograph to ensure minimal disruption. Then, we used micro computerized tomography (micro-CT) to scan different sections of the reservoir in order to create digital models that allowed us to determine parameters such as the fracture shape and …

    texas Repository record for Fracture characterization of the hydraulic fracture test site HFTS2 with X-ray microtomography (opens in a new tab)

  17. Structure and function in primary open angle glaucoma

    … nerve head (ONH) using the Heidelberg Retina Tomograph (HRT); retinal nerve fibre layer (RNFL) thickness using the HRT and using optical coherence tomography with the Optical Coherence Tomography Scanner (OCT); the visual field using white-on-white (W-W), short-wavelength (SWAP) and Frequency …

    aston Download PDF for Structure and function in primary open angle glaucoma (opens in a new tab)

Page 1 of 3