Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 10531 for “"tomography"”.

  1. Concentrated network tomography and bound-based network tomography

    … the tremendous overhead. Alternatively, network tomography, a technique that infers the unobserved network characteristics (e.g., link delays) from a small number of measurements (e.g., end-to-end path delays), is a promising solution for monitoring the internal network state in an e cient and e …

    uvic Repository record for Concentrated network tomography and bound-based network tomography (opens in a new tab)

  2. Bandwidth tomography

    Bandwidth tomography—inferring the bandwidth of internal network links from end-to-end path bandwidth measurements—is a long-standing open problem in network tomography. The core challenge arises from the fact that no existing mathematical framework directly addresses the inverse problem formulated …

    uvic Repository record for Bandwidth tomography (opens in a new tab)

  3. Network Tomography

    While conventional tomography is associated to the Radon transform in Euclidean spaces, electrical impedance tomography, or EIT, is associated to the Radon transform in the hyperbolic plane. In this dissertation, we discuss some recent work on network tomography that can be associated to a problem …

    maryland Repository record for Network Tomography (opens in a new tab)

  4. Network Tomography

    … metrics such as loss and delay. Network tomography aims to infer these edge weights from their pathwise versions measured on a set of intersecting paths between a subset of boundary vertices, and even the underlying graph when this is not known. In particular, temporal correlations …

    tamu Repository record for Network Tomography (opens in a new tab)

  5. ELECTRICAL CAPACITANCE TOMOGRAPHY

    Capacitance tomography is a process imaging technique based on capacitance sensing mechanism. There are still some defects in the current theories of ECT technology. In this thesis work, the principle of ECT technology is analyzed and the discomfort and morbidity of the reverse problem of ECT image …

    nus Repository record for ELECTRICAL CAPACITANCE TOMOGRAPHY (opens in a new tab) Download file for ELECTRICAL CAPACITANCE TOMOGRAPHY (opens in a new tab)

  6. Cylindrical RF tomography

    Tomography allows the examination of an object's interior without having to destroy the object. There have been many forms of tomography including MRIs and CT scans. All forms of tomography infer the interior of an object from a set of measurements. An algorithm to infer the features of infinite …

    ubc Repository record for Cylindrical RF tomography (opens in a new tab) Download PDF for Cylindrical RF tomography (opens in a new tab)

  7. Translational Photoacoustic Tomography

    … and ultrasonic detection, photoacoustic tomography (PAT) offers deep imaging with high resolution. With optical excitation, PAT maintains the high contrast of optical imaging. Because of the low scattering of ultrasonic waves in tissue, PAT achieves high spatial resolution at depths. …

    wustl Repository record for Translational Photoacoustic Tomography (opens in a new tab)

  8. Neutron strain tomography

    … of a technique known as ‘neutron strain tomography’, in order to non-destructively map, in three dimensions, residual elastic strain. The fundamental idea behind this research is that the strain values provided by through thickness transmission strain measurements are the result of …

    oxford Repository record for Neutron strain tomography (opens in a new tab)

  9. Limited angle tomography

    This thesis investigates the limited angle tomography problem where axial reconstructions are produced from few measured projection views covering a 100° angular range. Conventional full angle tomography requires at least a 180° range of projection views of the patient at a fine angular spacing. …

    cape-town Repository record for Limited angle tomography (opens in a new tab)

  10. Multi-modal diffuse optical tomography and bioluminescence tomography system for preclinical imaging

    … in small animals by combining 3D bioluminescence tomography (BLT; reconstruction-based 3D imaging of internal bioluminescent reporter distributions), diffuse optical tomography (DOT; reconstruction-based imaging of optical parameter distributions) and optical surface capture techniques. The key …

    birmingham Download PDF for Multi-modal diffuse optical tomography and bioluminescence tomography system for preclinical imaging (opens in a new tab)

  11. Colorectal and Ovarian Cancer Imaging Using Optical Coherence Tomography and Photoacoustic Tomography

    … methods. In this thesis, two optical coherence tomography (OCT) catheters are introduced for ex vivo sample studies and in vivo patient studies to differentiate malignant tumor from benign tissue. A distal-end mini-motor based optical coherence tomography (OCT) catheter is built to investigate …

    wustl Repository record for Colorectal and Ovarian Cancer Imaging Using Optical Coherence Tomography and Photoacoustic Tomography (opens in a new tab)

  12. Computed tomography coronary angiography and positron emission tomography in acute coronary syndrome

    … and refining risk stratification. Computed tomography coronary angiography can identify and characterise morphologically milder but clinically important coronary atherosclerosis. However, its clinical utility has not yet been widely examined in intermediate-risk patients with suspected acute …

    edinburgh Repository record for Computed tomography coronary angiography and positron emission tomography in acute coronary syndrome (opens in a new tab)

  13. Lamb wave diffraction tomography

    … of Lamb waves to travel over large distances, tomography becomes the method of choice for solving NDE problems. This work explores different tomographic reconstruction techniques to graphically represent the Lamb wave data in quantitative maps that can be easily interpreted by technicians. …

    wm-mary Repository record for Lamb wave diffraction tomography (opens in a new tab)

  14. Multiple-source network tomography

    … from end-to-end measurements is called network tomography. This thesis investigates the general network tomography problem involving multiple sources and receivers, building on existing single source techniques. Using multiple sources potentially provides a more accurate and refined …

    rice Repository record for Multiple-source network tomography (opens in a new tab)

  15. Micro-Autoradiographic Fusion Tomography

    … will refer to as micro-autoradiographic fusion tomography (MAFT), are not currently available. We will illustrate the use of MAFT with the distribution of vascular endothelial growth factor (VEGF) in subcutaneous tissue. [14C]-VEGF will be injected into rat subcutaneous tissue. VEGF has been …

    usf Repository record for Micro-Autoradiographic Fusion Tomography (opens in a new tab)

  16. Ultrasound-modulated optical tomography

    Ultrasound-modulated optical tomography is modeled by a linear integral equation and an inverse problem involving a diffusion equation in n spatial dimensions, n=2, 3. Based on measured data, the optical absorption coefficient μ is reconstructed inside of a given domain. We make a two-step …

    tamu Repository record for Ultrasound-modulated optical tomography (opens in a new tab)

Page 1 of 527