Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 38 for “"tone burst"”.
-
The effects of age on tone-burst evoked oto-acoustic emissions
Thesis (M.A.)--Michigan State University. Department of Audiology and Speech Sciences, 1993
-
Optical generation of tone-burst Rayleigh surface waves for nonlinear ultrasonic measurements
… first focuses on the optical generation of tone-burst surface acoustic waves in a metallic specimen. Two methods that use laser light as an optical source are compared for generating surface acoustics waves in the 5 MHz range. Both the shadow mask and diffraction grating are used to convert …
-
The Effect of Rate on Tone Burst Extratympanic Electrocochleography in Adults with Normal Hearing
The recording of electrocochleography (ECochG) to tone burst stimuli with a high rate is hypothesized to provide advantages over standard click ECochG with slow rate. Specifically, the use of tone burst stimuli presented at a high rate may enhance the summating potential (SP) while also reducing …
-
Digital filtering of auditory brain-stem responses (ABR) using tone-burst stimuli in dogs
Thesis (Ph. D.)--Michigan State University. Department of Audiology and Speech Sciences, 1993
-
A Comparison of Tone Burst Auditory Brainstem Response (ABR) Latencies Elicited With and Without Notched Noise Masking
… widespread stimulus used to estimate the pure tone audiogram as part of auditory brainstem response (ABR) testing. The click is characterized by its broad spectral content and rapid onset, which may not make it the best choice for frequency specificity. An alternative stimulus is a short …
-
Accuracy of 40-Hz Automated and Sinusoidal ASSR and Tone-Burst ABR Thresholds in Normal-Hearing Adults Using Kalman-Weighted Filtering
… of: a) 40-Hz sASSR thresholds compared to both toneburst-ABR and behavioral thresholds; and b) automated ASSR (aASSR) in a semi-alert population. Behavioral and electrophysiological thresholds for 500, 2000 and 4000 Hz TB and narrow-band chirp stimuli were obtained using both 2000 and 4000 …
-
Investigation to Examine the Profile of Auditory Brainstem and Hearing Thresholds Using Tone Burst Audiometry Brainstem Response in a Preclinical Migraine Model
… trigeminal activation and pain signaling. Tone burst auditory brainstem responses (ABRs) were measured using the Duet device (Intelligent Hearing Systems, Miami, FL) to determine the effects of migraine pathology on brainstem auditory pathways in eight male and six female rats at baseline …
-
Point process models for discharge patterns of single units in the lateral superior olive of the cat
… is developed for responses to continuous tone and tone burst stimuli. The statistics of each process are described using the intervals between events in the response. We find that a first order Markovian model is sufficient to describe the observed serial dependence of the inter-spike …
-
Human frequency following response correlates of interaural-intensity differences
… response (FFR) evoked by 500 Hz tone bursts and the alterations of the BIC as a function of interaural-intensity differences (IID) were investigated. The FFR BIC was demonstrated and was shown to systematically decrease with increasing IID, much like the summed monaural response. …
-
Effect of Intensity Increment on P300 Amplitude
… The "frequent stimulus" was a 1000 Hz or 4000 Hz tone burst, gated with a rise and fall time of 10 msec and 20 msec plateau, presented at 75 dBn HL The "oddball stimulus" was a tone burst of the same frequency (1000 Hz or 4000 Hz)presented at 77, 79, or 81 dBn HL. A four-channel recording was made …
-
Surface Acoustic Waves-Based Point-Of-Care Biosensor
… thesis, an ultrasensitive and highly selective tone burst-based surface acoustic wave sensor is developed for the detection of the cyanotoxins present in a water sample utilized for agricultural and human consumption purposes. The designed biosensing platform consists of novel concentric …
-
An investigation on the use of micro-ultrasonic-transducers for anticancer drugs cytotoxicity enhancement
… also found to be consistent over four months. Tone-burst ultrasound (32 Watt/cm2, 20% Duty Cycle, 50msec burst period) was found to significantly (p<0.01) enhance cytotoxicity when used in combination with 20pM doxorubicin compared to doxorubicin-alone or ultrasound-alone controls. With 30 …
-
Auditory-nerve and energy-detection models of temporal summation in hearing: a theoretical and experimental investigation
… result that, ceteris paribus, a brief tone burst is more readily letected than a brief gap in a tone. Two models, one based on the neuroelectrical activity of the auditory nerve and one on energy-detection theory, are presented and developed in detail: both are shown capable of …
-
Spatial Irregularities Of Compound Action Potential Origination In Individual Cochleae
… collected at around 90-second intervals using tone burst stimuli during the injections allowed evaluation of the neural responses over time. Responses to higher stimulation levels revealed a later ablation time, indicating they originate from a more basal, higher frequency region than 2 kHz. …
-
A miniature Microcontroller-Based Electrocardiographic Patient Monitoring Device Using Telemetry
… using a robust QRS detection algorithm. A dual tone multifrequency tone (DTMF) is generated by the microcontroller after a valid QRS complex is detected. A DTMF tone consists of two low frequency sine waves which are added together. Different tones are generated indicating either normal sinus …
-
Developing an Ideal Clinical Protocol for Recording Cervical Vestibular Evoked Myogenic Potentials
… conditions. Results indicated that a 500 Hz tone burst, regardless of the duration, resulted in the most robust cVEMP response across all subjects for all locations. Additionally, the top electrode location on the SCM resulted in the most robust cVEMP response across all subjects and under …
-
Underwater multimode directional transducer evaluation
… beam patterns. In this technique, a single-cycle tone burst is emitted at a low frequency repetition rate and excites the driving transducer. The signal analyzer excludes the acoustic reverberations from the tank walls by adequate adjusting of the FFT sampling window. Additionally, for …
-
Characterization of fatigue damage in A36 steel specimens using nonlinear Rayleigh surface waves
… for the nonlinear ultrasonic measurements. Tone burst Rayleigh wave signals are generated and detected using a pair of oil coupled wedge transducers. The amplitudes of the first and second harmonic are measured at varying propagation distances to obtain the nonlinearity parameter for a given …
-
Characterization of damage due to stress corrosion cracking in carbon steel using nonlinear surface acoustic waves
… transducers are used to generate and detect tone burst Rayleigh wave signals. The amplitudes of the received fundamental and second harmonic waves are measured at varying propagation distances to obtain a measure for the acoustic nonlinearity of the material. The results show a …
-
The Effect of Activating the Olivocochlear Bundle Ipsilaterally and Contralaterally on Cochlear Microphonic in Humans
… Cochlear microphonic (CM) for 0.5 and 2.0 kHz tone burst (TB) was recorded in 17 female subjects (20-30 years old) while activating the crossed or uncrossed MOCB. Activation of the MOCB was completed at three levels of broadband noise (BBN) (40, 50, and 60 dBSPL). CM amplitude was recorded …
Page 1 of 2