Showing 1 to 20 of 41 for “"total knee replacements"”.
-
Numerical Simulation of Wear of Total Knee Replacements
… of a computer program to simulate the wear on knee implants over a standardized gait cycle. The contact problems during the gait cycle are formulated using linear elasticity with a linear non-penetration condition. Archard's wear law is used to estimate long-term wear. The algebraic problem …
-
Wear and Boundary Lubrication in Modular Total Knee Replacements
… (bone resorption) can lead to failure of modular total knee replacements and make expensive revision surgery necessary. Gamma-in-air sterilization of the PE insert and having a modular tibial component are both risk factors for excessive backside wear that contribute to osteolysis and implant …
-
Piezoresistive UHMWPE WMCNT Sensors for Instrumented Total Knee Replacements
… developed and validate an instrumented total knee replacement using a novel piezoresistive polymeric sensor. The addition of multi-walled carbon nanotubes (MWCNT) as electrically conducting fillers to the ultra-high molecular weight polyethylene (UHMWPE) transforms the electrically …
-
Total Knee Replacements: Component Design, Pain Prevention and Research Techniques
Total knee arthroplasty is a surgical procedure in which the knee is resurfaced with implants to relieve pain. This thesis presents computed tomography and radiography methods to determine the relative position (kinematics) for the patellofemoral and tibiofemoral joints in vivo for a full range of …
-
PRIMARY FLEXION AXIS SELECTION IN TOTAL KNEE REPLACEMENTS USING COMPUTATIONAL ANALYSIS
Total knee replacements (TKR) are one of the most frequently implanted medical devices, with over 600,000 procedures performed in the United States in 2012. In order to ensure TKR longevity, wear tests are frequently conducted on these implants prior to patient implantation. Variations in implant …
-
Multiobjective Design Optimization of Total Knee Replacements Considering UHMWPE Wear and Kinematics
Total knee replacement is the gold standard treatment for restoring mobility and relieving pain associated with osteoarthritis when other medical therapy has failed. Revision surgery is necessary when the replaced knee fails, which is often a result of implant damage (such as wear) or poor …
-
Polyethylene wear modeling in modular total knee replacements using finite element simulation
… articular and backside polyethylene (PE) wear of total knee replacements (TKRs) could enable the optimization of TKRs for the reduction of polyethylene wear, thereby improving the long term success of TKRs. A finite element model was developed for the TKR and the results were implemented in a …
-
A Finite Element Analysis of Tibial Stem Geometry for Total Knee Replacements
… shielding of the tibia for patients with a total knee replacement. Finite element analysis was used to study different tibial stem geometry types, as well as a vast array of different geometric sizes. Both a peg and stem type geometry were analyzed and compared in order to determine what …
-
Computational wear simulations in total knee replacements with consideration for energy dissipation and colloid-mediated boundary lubrication
… wear simulations may enable the optimization of total knee replacements for the reduction of polyethylene wear, thereby potentially improving the long term success of total knee replacements. However, previously existing computational wear models have only demonstrated weak correlations (R2<0.65) …
-
An Experimental Study of an Advanced Polymeric Material for Use in Total Knee Replacements Including Gait Analysis of Mobile Knee Bearings
… Stress (LCS)™ Rotating Platform and Meniscal knee bearing systems and to investigate the tribological properties of a new polymer for potential application in total joint replacement. Thus, clinical studies were performed on subjects having the LCSTM Rotating Platform knee bearing and subjects …
-
Research into the Design and Validation of an Innovative Intraoperative Load Sensor for Total Knee Replacements through Experimental and Cadaveric Investigations
Balancing the force between compartments in the knee joint during a Total Knee Replacement (TKR) is a vital parameter for surgeons to achieve successful outcomes for patients due to the complexity of the joint, articulating surfaces, tendons, and ligaments. These structures are all impacted by the …
-
Parameter establishment for the design of interference fit tibial component of total knee replacement
… Over 4.7 million Americans are living with total knee replacements with an additional one million receiving the surgery each year. With these numbers predicted to grow each year, there is a need for a more robust and effective prosthetic to improve patient results and reduce surgery costs. …
-
Spatial Sensors for Quantitative Assessment of Retrieved Arthroplasty Bearings
… assessments of arthroplasty bearings, including total knee replacements, unicompartmental knee replacements, and total hip replacements. The approach is to assess bearings that endured a finite duration of function in patients, with particular emphasis on expanding our understanding of the …
-
Design of an e-textile sleeve for tracking knee rehabilitation for older adults
The occurrence of total knee replacements is increasing in the United States for persons over the age of 45 because they are inexpensive and a very effective method for treating degenerative joint diseases. Rehabilitation requires regular access to a wide variety of resources and personnel and, as …
-
Design of an e-Textile sleeve for tracking knee rehabilitation for older adults
The occurrence of total knee replacements is increasing in the United States for persons over the age of 45 because they are inexpensive and a very effective method for treating degenerative joint diseases. Rehabilitation requires regular access to a wide variety of resources and personnel and, as …
-
Retrospective Chart Review of Patients Following Unilateral Total Knee Replacement to Assess Achievement of Functional Milestones Based on Type of Anesthetic Used Intra-Operatively
PURPOSE: Given the large number of Total Knee Replacements (TKR) performed annually in the US and the prediction that those numbers will increase, providing optimal analgesia during TKR is an important strategy for reducing cost and improving patient outcomes. Currently, no standard analgesia …
-
SURFACE DAMAGE IN RETRIEVED TOTAL KNEE REPLACEMENT FEMORAL COMPONENTS
The metallic femoral components of total knee replacements are subject to in vivo surface damage and roughening that can severely limit the service lifetime of the bearing system. To date, there are no national standards by which to characterize the severity and damage modes of these critical …
-
Development of a method for in vivo mechanical characterization of articular cartilage /
… cartilage samples from six patients undergoing total knee replacements and collecting information on several biomarkers with known relevance to osteoarthritis. Specifically, the concentrations of several proteins which may be determined in a standard hospital lab were analyzed. The samples were …
-
Η ολική αρθροπλαστική του γόνατος με ενδοπρόθεση τύπου gliding meniscal knee: Κλινική αξιολόγηση 230 περιπτώσεων
In this thesis 230 total knee replacements with the Gliding Meniscal Knee prosthesis are reviewed; they were all performed by the same surgeon. The patients' age was from 33 to 88 (mean 66.28), of which 23.48% were men and 76.52% women, 56.96% osteoarthritic and 43.03% rheumatoid. The continuous …
Page 1 of 3